Improved DNA sequencing accuracy and detection of heterozygous alleles using manganese citrate and different fluorescent dye terminators

被引:0
|
作者
Korch, C [1 ]
Drabkin, H
机构
[1] Univ Colorado, Ctr Canc, Denver, CO 80262 USA
[2] Univ Colorado, Hlth Sci Ctr, Sch Med, Div Med Oncol, Denver, CO 80262 USA
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces base-calling accuracy and limits heterozygous allele detection, favoring use of dye-labeled primers for this purpose. We have discovered that the addition of a manganese salt to the PE Applied Biosystems dye-terminator sequencing kits overcomes these limitations for the older rhodamine dyes as well as the more recent dichloro-rhodamine dyes (dRhodamine and BigDyes). Addition of manganese to reactions containing dRhodamine-based dye terminators produced the highest base-calling accuracy. This combination resulted in the most uniform electropherogram profiles, superior to those produced by BigDye terminators and published for dye primers, and Facilitated detection of heterozygous alleles.
引用
收藏
页码:588 / 595
页数:8
相关论文
共 24 条
  • [1] Manganese citrate improves base-calling accuracy in DNA sequencing reactions using rhodamine-based fluorescent dye-terminators
    Korch, C
    Drabkin, H
    NUCLEIC ACIDS RESEARCH, 1999, 27 (05) : 1405 - 1407
  • [2] New dye-labeled terminators for improved DNA sequencing patterns
    Rosenblum, BB
    Lee, LG
    Spurgeon, SL
    Khan, SH
    Menchen, SM
    Heiner, CR
    Chen, SM
    NUCLEIC ACIDS RESEARCH, 1997, 25 (22) : 4500 - 4504
  • [3] Utility of thiol-cross-linked fluorescent dye labeled terminators for DNA sequencing
    Nampalli, S
    McDougall, MG
    Lavrenov, K
    Xiao, HG
    Kumar, S
    BIOCONJUGATE CHEMISTRY, 2002, 13 (03) : 468 - 473
  • [4] Four-color DNA sequencing by synthesis using cleavable fluorescent nucleotide reversible terminators
    Ju, Jingyue
    Kim, Dae Hyun
    Bi, Lanrong
    Meng, Qinglin
    Bai, Xiaopeng
    Li, Zengmin
    Li, Xiaoxu
    Marma, Mong Sano
    Shi, Shundi
    Wu, Jian
    Edwards, John R.
    Romu, Aireen
    Turro, Nicholas J.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (52) : 19635 - 19640
  • [5] Two-step cycle sequencing improves base ambiguities and signal dropouts in DNA sequencing reactions using energy-transfer-based fluorescent dye terminators
    Wen, L
    MOLECULAR BIOTECHNOLOGY, 2001, 17 (02) : 135 - 142
  • [6] Two-step cycle sequencing improves base ambiguities and signal dropouts in DNA sequencing reactions using energy-transfer-based fluorescent Dye terminators
    Long Wen
    Molecular Biotechnology, 2001, 17 : 135 - 142
  • [7] A dye terminator method for automated DNA sequencing using four fluorescent dideoxynucleosides and thermal cycling
    Takumi, T
    Fujiwake, H
    Kurachi, Y
    ANALYTICAL SCIENCES, 1997, 13 (05) : 735 - 739
  • [8] A Dye Terminator Method for Automated DNA Sequencing Using Four Fluorescent Dideoxynucleosides and Thermal Cycling
    Toru Takumi
    Hideshi Fujiwake
    Yoshihisa Kurachi
    Analytical Sciences, 1997, 13 : 735 - 739
  • [9] Heterozygote and mutation detection by direct automated fluorescent DNA sequencing using a mutant Taq DNA polymerase
    Chadwick, RB
    Conrad, MP
    McGinnis, MD
    JohnstonDow, L
    Spurgeon, SL
    Kronick, MN
    BIOTECHNIQUES, 1996, 20 (04) : 676 - 683
  • [10] Detection of G-quartet structure in a DNA aptamer stationary phase using a fluorescent dye
    Joyce, MV
    McGown, LB