Total and unicompartmental knee replacement. Patient-specific Instrumentation

被引:0
|
作者
Koester, G. [1 ]
Biro, C. [1 ]
机构
[1] Schon Klin Lorsch, Abt Orthopad & Unfallchirurg, Wilhelm Leuschner Str 10, D-64653 Lorsch, Germany
来源
ORTHOPADE | 2016年 / 45卷 / 04期
关键词
Computer-assisted Surgery; Magnetic resonance imaging; Osteoarthritis of knee; Total knee replacement; Unicondylar knee replacement; MECHANICAL AXIS ALIGNMENT; ARTHROPLASTY; ACCURACY;
D O I
10.1007/s00132-016-3245-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The objective of patient-specific instrumentation (PSI ZimmerA (R)) technology is to optimize positioning and selection of components as well as surgical procedure in uni- and bicompartimental knee replacement. The article contains a description of the planning and surgical technique and evaluates the method based on own results and literature. Methods. Using MRI or CT scans a virtual 3D model of the joint is created in order to simulate and plan the implant positioning. According to these data, pin placement and/or cutting guides are produced, which enable the surgeon to transfer the planning to the surgical procedure. In a prospective comparative study 88 patients (44 per each of the two techniques) were operated by one surgeon receiving the same TKA using either MRI-based PSI or a conventional technique. The number of surgical trays, operating time, intraoperative changes and frontal alignment using a full leg xaEuroray (70 cases) were compared. In 17 patients the method was applied with unicondylar knee replacement. Results. Anatomical abnormalities could be detected preoperatively and considered during the operation. With PSI the number of trays could be reduced and predictability of the component size was more precise. Intraoperative changes became necessary only for distal femoral (25 %) and proximal tibial (36 %) resection and tibial rotation (40 %). Alignment was more precise in the PSI cases Discussion PSI using the applied technique proved to be practicable and reliable. The advantages of precise planning became obvious. Results concerning alignment are inconsistent in the literature. Soft tissue balancing has only been included in the technique to a limited degree so far. PSI is still in an early stage of development and further development opportunities should be exploited before final assessment.
引用
收藏
页码:302 / +
页数:10
相关论文
共 50 条
  • [31] Patient-specific implants for lateral unicompartmental knee arthroplasty
    Marco K. Demange
    Arvind Von Keudell
    Christian Probst
    Hiroshi Yoshioka
    Andreas H. Gomoll
    International Orthopaedics, 2015, 39 : 1519 - 1526
  • [32] Patient-specific implants for lateral unicompartmental knee arthroplasty
    Demange, Marco K.
    Von Keudell, Arvind
    Probst, Christian
    Yoshioka, Hiroshi
    Gomoll, Andreas H.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (08) : 1519 - 1526
  • [33] A systematic review and meta-analysis of patient-specific instrumentation for improving alignment of the components in total knee replacement
    Thienpont, E.
    Schwab, P. E.
    Fennema, P.
    BONE & JOINT JOURNAL, 2014, 96B (08): : 1052 - 1061
  • [34] A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
    Chareancholvanich, K.
    Narkbunnam, R.
    Pornrattanamaneewong, C.
    BONE & JOINT JOURNAL, 2013, 95B (03): : 354 - 359
  • [35] Accuracy of Coronal Plane Mechanical Alignment in a Customized, Individually Made Total Knee Replacement with Patient-Specific Instrumentation
    Levengood, Gary A.
    Dupee, Jack
    JOURNAL OF KNEE SURGERY, 2018, 31 (08) : 792 - 796
  • [36] The efficacy and safety of patient-specific instrumentation in primary total knee replacement: a systematic review and meta-analysis
    Hinloopen, J. H.
    Puijk, R.
    Nolte, P. A.
    Schoones, J. W.
    de Ridder, R.
    Pijls, B. G.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (03) : 245 - 252
  • [37] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Chen, Jerry Yongqiang
    Yeo, Seng Jin
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Chin, Pak Lin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 630 - 635
  • [38] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [39] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [40] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +