Definition for Rheumatoid Arthritis Erosions Imaged with High Resolution Peripheral Quantitative Computed Tomography and Interreader Reliability for Detection and Measurement

被引:63
|
作者
Barnabe, Cheryl [1 ,2 ]
Toepfer, Dominique [3 ]
Marotte, Hubert [4 ,5 ]
Hauge, Ellen-Margrethe [6 ,7 ]
Scharmga, Andrea [8 ]
Kocijan, Roland [9 ]
Kraus, Sebastian [10 ,11 ]
Boutroy, Stephanie [12 ]
Schett, Georg [10 ]
Keller, Kresten Krarup [6 ]
de Jong, Joost [8 ]
Stok, Kathryn S. [13 ]
Finzel, Stephanie [10 ,14 ]
机构
[1] Univ Calgary, Dept Med, Calgary, AB, Canada
[2] Univ Calgary, Dept Community Hlth Sci, Calgary, AB, Canada
[3] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[4] Univ Hosp St Etienne, Inst Natl Sante & Rech Med, St Etienne, France
[5] Univ Hosp St Etienne, Rheumatol Dept, St Etienne, France
[6] Aarhus Univ Hosp, Dept Rheumatol, Aarhus, Denmark
[7] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[8] Maastricht Univ, Dept Rheumatol, Med Ctr, Maastricht, Netherlands
[9] Med Univ Vienna, St Vincent Hospital Med Dept 2, VINFORCE Study Grp, Acad Teaching Hosp, Vienna, Austria
[10] Univ Erlangen Nurnberg, Dept Internal Med Rheumatol & Immunol 3, Erlangen, Germany
[11] Kantonsspital Baden, Baden, Switzerland
[12] Hop Edouard Herriot Kresten, INSERM, Lyon, France
[13] Swiss Fed Inst Technol, Zurich, Switzerland
[14] Univ Med Ctr Freiburg, Dept Rheumatol & Clin Immunol, Freiburg, Germany
关键词
RHEUMATOID ARTHRITIS; EROSIONS; HR-PQCT; JOINT SPACE WIDTH; BONE EROSIONS; METACARPOPHALANGEAL JOINTS; WRIST; QUANTIFICATION; CLASSIFICATION; CRITERIA; REPAIR; HAND;
D O I
10.3899/jrheum.160648
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. High-resolution peripheral quantitative computed tomography (HR-pQCT) sensitively detects erosions in rheumatoid arthritis (RA); however, nonpathological cortical bone disruptions are potentially misclassified as erosive. Our objectives were to set and test a definition for pathologic cortical bone disruptions in RA and to standardize reference landmarks for measuring erosion size. Methods. HR-pQCT images of metacarpophalangeal joints of RA and control subjects were used in an iterative process to achieve consensus on the definition and reference landmarks. Independent readers (n = 11) applied the definition to score 58 joints and measure pathologic erosions in 2 perpendicular multiplanar reformations for their maximum width and depth. Interreader reliability for erosion detection and variability in measurements between readers [root mean square coefficient of variation (RMSCV), intraclass correlation (ICC)] were calculated. Results. Pathologic erosions were defined as cortical breaks extending over a minimum of 2 consecutive slices in perpendicular planes, with underlying trabecular bone loss and a nonlinear shape. Interreader agreement for classifying pathologic erosions was 90.2%, whereas variability for width and depth erosion assessment was observed (RMSCV perpendicular width 12.3%, axial width 20.6%, perpendicular depth 24.0%, axial depth 22.2%; ICC perpendicular width 0.206, axial width 0.665, axial depth 0.871, perpendicular depth 0.783). Mean erosion width was 1.84 mm (range 0.16-8.90) and mean depth was 1.86 mm (range 0.30-8.00). Conclusion. We propose a new definition for erosions visualized with HR-pQCT imaging. Interreader reliability for erosion detection is good, but further refinement of selection of landmarks for erosion size measurement, or automated volumetric methods, will be pursued.
引用
收藏
页码:1935 / 1940
页数:6
相关论文
共 50 条
  • [41] SENSITIVE DETECTION OF DYNAMIC CHANGES OF BONE EROSIONS IN INFLAMMATORY ARTHRITIS BY MUSCULOSKELETAL ULTRASOUND: A COMPARATIVE ANALYSIS WITH HIGH-RESOLUTION PERIPHERAL QUANTITATVE COMPUTED TOMOGRAPHY
    Finzel, S.
    Schett, G.
    Kraus, S.
    Voll, R.
    Backhaus, M.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1425 - 1425
  • [42] Detecting new erosions in rheumatoid arthritis over one year - Radiography and high-resolution computed tomography of finger joints
    Therkildsen, Josephine
    Klose-Jensen, Rasmus
    Hanel, Mathias
    Langdahl, Bente L.
    Thomsen, Jesper S.
    Manske, Sarah L.
    Keller, Kresten K.
    Hauge, Ellen-Margrethe
    JOINT BONE SPINE, 2025, 92 (01)
  • [43] Quantitative Analysis of High-resolution Computed Tomography Scans in Subclinical Rheumatoid Arthritis Airways Disease
    Khan, S.
    Kim, T.
    Lee, D. H.
    Abdolijomoor, A.
    Bang, T.
    Sachs, P.
    Deane, K.
    Demoruelle, K.
    Choi, J.
    Castro, M.
    Lee, J. S.
    Matson, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [44] Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography
    Dohn, Uffe Moller
    Ejbjerg, Bo J.
    Hasselquist, Maria
    Narvestad, Eva
    Moller, Jakob
    Thomsen, Henrik S.
    Ostergaard, Mikkel
    ARTHRITIS RESEARCH & THERAPY, 2008, 10 (01)
  • [45] Detection of bone erosions in early rheumatoid arthritis: 3D ultrasonography versus computed tomography
    Peluso, G.
    Bosello, S. L.
    Gremese, E.
    Mirone, L.
    Di Gregorio, F.
    Di Molfetta, V.
    Pirronti, T.
    Ferraccioli, G.
    CLINICAL RHEUMATOLOGY, 2015, 34 (07) : 1181 - 1186
  • [46] Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography
    Uffe Møller Døhn
    Bo J Ejbjerg
    Maria Hasselquist
    Eva Narvestad
    Jakob Møller
    Henrik S Thomsen
    Mikkel Østergaard
    Arthritis Research & Therapy, 10
  • [47] Detection of bone erosions in early rheumatoid arthritis: 3D ultrasonography versus computed tomography
    G. Peluso
    S. L. Bosello
    E. Gremese
    L. Mirone
    F. Di Gregorio
    V. Di Molfetta
    T. Pirronti
    G. Ferraccioli
    Clinical Rheumatology, 2015, 34 : 1181 - 1186
  • [48] Development of a scoring method to visually score cortical interruptions on high-resolution peripheral quantitative computed tomography in rheumatoid arthritis and healthy controls
    Scharmga, Andrea
    Peters, Michiel
    van den Bergh, Joop P.
    Geusens, Piet
    Loeffen, Daan
    van Rietbergen, Bert
    Schoonbrood, Thea
    Vosse, Debby
    Weijers, Rene
    van Tubergen, Astrid
    PLOS ONE, 2018, 13 (07):
  • [49] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    BONE, 2009, 45 (03) : 473 - 479
  • [50] The Role of High-resolution Peripheral Quantitative Computed Tomography as a Biomarker for Joint Damage in Inflammatory Arthritis Introduction
    Tam, Lai-Shan
    JOURNAL OF RHEUMATOLOGY, 2016, 43 (10) : 1911 - 1913