Thermodynamic modeling of protein retention in mixed-mode chromatography: An extended model for isocratic and dual gradient elution chromatography

被引:18
|
作者
Lee, Yi Feng [1 ]
Graalfs, Heiner [2 ]
Frech, Christian [1 ]
机构
[1] Univ Appl Sci Mannheim, Inst Biochem, Paul Wittsack Str 10, D-68163 Mannheim, Germany
[2] Merck KGaA, Darmstadt, Germany
关键词
Dual gradient elution chromatography; Isocratic elution chromatography; Mixed-mode chromatography; Monoclonal antibody; Thermodynamic modeling; HYDROPHOBIC-INTERACTION CHROMATOGRAPHY; ION-EXCHANGE CHROMATOGRAPHY; ANTIBODY PURIFICATION; ELECTROSTATIC INTERACTIONS; MONOCLONAL-ANTIBODIES; OPERATING-CONDITIONS; ADSORPTION; SALT; LIGANDS; ADSORBENTS;
D O I
10.1016/j.chroma.2016.08.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An extended model is developed, to describe protein retention in mixed-mode chromatography based on thermodynamic principles. Special features are the incorporation of pH dependence of the ionic interaction on a mixed-mode resin and the addition of a water term into the model which enables one to describe the total number of water molecules released at the hydrophobic interfaces upon protein-ligand binding. Examples are presented on how to determine the model parameters using isocratic elution chromatography. Four mixed-mode anion-exchanger prototype resins with different surface chemistries and ligand densities were tested using isocratic elution of two monoclonal antibodies at different pH values (7-10) and encompassed a wide range of NaCl concentrations (0-5 M). U-shape mixed-mode retention curves were observed for all four resins. By taking into account of the deprotonation and protonation of the weak cationic functional groups in these mixed-mode anion-exchanger prototype resins, conditions which favor protein-ligand binding via mixed-mode strong cationic ligands as well as conditions which favor protein-ligand binding via both mixed-mode strong cationic ligands and non-hydrophobic weak cationic ligands were identified. The changes in the retention curves with pH, salt, protein, and ligand can be described very well by the extended model using meaningful thermodynamic parameters like Gibbs energy, number of ionic and hydrophobic interactions, total number of released water molecules as well as modulator interaction constant. Furthermore, the fitted model parameters based on isocratic elution data can also be used to predict protein retention in dual salt-pH gradient elution chromatography. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 101
页数:15
相关论文
共 50 条
  • [41] A high-throughput approach to developing and optimizing mixed-mode membrane chromatography for protein purification
    McKechnie, William S.
    Thom, Volkmar
    Kupracz, Lukas
    Pollard, Jennifer
    Kandula, Sunitha
    Welsh, John
    BIOTECHNOLOGY PROGRESS, 2023, 39 (02)
  • [42] GRADIENT ELUTION IN LIQUID-CHROMATOGRAPHY .4. VERIFICATION OF THEORETICAL RELATIONSHIPS FOR ELUTION CHARACTERISTICS (RETENTION VOLUME, BAND WIDTH, RESOLUTION, PLATE NUMBER) IN ADSORPTION CHROMATOGRAPHY ON SILICA USING STEPWISE AND COMBINED (STEPWISE-GRADIENT) ELUTION AND SOME CONSIDERATIONS CONCERNING SOLVENT-PROGRAMMED AND ISOCRATIC ELUTION CHROMATOGRAPHYC
    JANDERA, P
    CHURACEK, J
    JOURNAL OF CHROMATOGRAPHY, 1975, 104 (01): : 9 - 21
  • [43] Development of gradient elution retention model in ion chromatography by using radial basis function artificial neural networks
    Bolanca, Tomislav
    Cerjan-Stefanovic, Stefica
    Lusa, Melita
    Regelja, Hrvoje
    Loncaric, Sven
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 86 (01) : 95 - 101
  • [44] Unfolding of a model protein on ion exchange and mixed mode chromatography surfaces
    Gospodarek, Adrian M.
    Hiser, Diana E.
    O'Connell, John P.
    Fernandez, Erik J.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1355 : 238 - 252
  • [45] Mixed-mode ion-exchangers and their comparative chromatographic characterization in reversed-phase and hydrophilic interaction chromatography elution modes
    Laemmerhofer, Michael
    Richter, Martin
    Wu, Junyan
    Nogueira, Raquel
    Bicker, Wolfgang
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (14) : 2572 - 2588
  • [46] Retention and selectivity effects caused by bonding of a polar urea-type ligand to silica: A study on mixed-mode retention mechanisms and the pivotal role of solute-silanol interactions in the hydrophilic interaction chromatography elution mode
    Bicker, Wolfgang
    Wu, JunYan
    Yeman, Helen
    Albert, Klaus
    Lindner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (07) : 882 - 895
  • [47] Theoretical Investigation of Dual-Mode Gradient Elution Chromatography Considering Simultaneous Variations in the Column Temperature and Solvent Composition
    Bashir, Muhammad Mohsin
    Perveen, Sadia
    Bilal, Muhammad
    Qamar, Shamsul
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2024, : 12083 - 12101
  • [48] Application of the reversed-phase liquid chromatographic model to describe the retention behaviour of polydisperse macromolecules in gradient and isocratic liquid chromatography
    Fitzpatrick, F
    Edam, R
    Schoenmakers, P
    JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) : 53 - 67
  • [49] Efficient purification of a recombinant protein from E. coli fermentate with mixed-mode chromatography resins
    Sulzberger, James
    Frisch, David
    Choi, Hyunsic
    Rushton, William
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [50] USE OF MIXED-MODE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDE AND PROTEIN MIXTURES
    HANCOCK, WS