Thermodynamic modeling of protein retention in mixed-mode chromatography: An extended model for isocratic and dual gradient elution chromatography

被引:18
|
作者
Lee, Yi Feng [1 ]
Graalfs, Heiner [2 ]
Frech, Christian [1 ]
机构
[1] Univ Appl Sci Mannheim, Inst Biochem, Paul Wittsack Str 10, D-68163 Mannheim, Germany
[2] Merck KGaA, Darmstadt, Germany
关键词
Dual gradient elution chromatography; Isocratic elution chromatography; Mixed-mode chromatography; Monoclonal antibody; Thermodynamic modeling; HYDROPHOBIC-INTERACTION CHROMATOGRAPHY; ION-EXCHANGE CHROMATOGRAPHY; ANTIBODY PURIFICATION; ELECTROSTATIC INTERACTIONS; MONOCLONAL-ANTIBODIES; OPERATING-CONDITIONS; ADSORPTION; SALT; LIGANDS; ADSORBENTS;
D O I
10.1016/j.chroma.2016.08.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An extended model is developed, to describe protein retention in mixed-mode chromatography based on thermodynamic principles. Special features are the incorporation of pH dependence of the ionic interaction on a mixed-mode resin and the addition of a water term into the model which enables one to describe the total number of water molecules released at the hydrophobic interfaces upon protein-ligand binding. Examples are presented on how to determine the model parameters using isocratic elution chromatography. Four mixed-mode anion-exchanger prototype resins with different surface chemistries and ligand densities were tested using isocratic elution of two monoclonal antibodies at different pH values (7-10) and encompassed a wide range of NaCl concentrations (0-5 M). U-shape mixed-mode retention curves were observed for all four resins. By taking into account of the deprotonation and protonation of the weak cationic functional groups in these mixed-mode anion-exchanger prototype resins, conditions which favor protein-ligand binding via mixed-mode strong cationic ligands as well as conditions which favor protein-ligand binding via both mixed-mode strong cationic ligands and non-hydrophobic weak cationic ligands were identified. The changes in the retention curves with pH, salt, protein, and ligand can be described very well by the extended model using meaningful thermodynamic parameters like Gibbs energy, number of ionic and hydrophobic interactions, total number of released water molecules as well as modulator interaction constant. Furthermore, the fitted model parameters based on isocratic elution data can also be used to predict protein retention in dual salt-pH gradient elution chromatography. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 101
页数:15
相关论文
共 50 条
  • [21] The benefits of mixed-mode chromatography columns for separation of peptides and protein digests
    Kadlecova, Zuzana
    Boudova, Hana
    Kalikova, Kveta
    MONATSHEFTE FUR CHEMIE, 2023, 154 (09): : 993 - 1002
  • [22] The benefits of mixed-mode chromatography columns for separation of peptides and protein digests
    Zuzana Kadlecová
    Hana Boudová
    Květa Kalíková
    Monatshefte für Chemie - Chemical Monthly, 2023, 154 : 993 - 1002
  • [23] IONIC STRENGTH DEPENDENCE OF PROTEIN RETENTION ON SUPEROSE-12 IN SEC-IEC MIXED-MODE CHROMATOGRAPHY
    CAI, CH
    ROMANO, VA
    DUBIN, PL
    JOURNAL OF CHROMATOGRAPHY A, 1995, 693 (02) : 251 - 261
  • [24] Retention characteristics of some antibiotic and anti-retroviral compounds in hydrophilic interaction chromatography using isocratic elution, and gradient elution with repeatable partial equilibration
    Heaton, James C.
    Smith, Norman W.
    McCalley, David V.
    ANALYTICA CHIMICA ACTA, 2019, 1045 : 141 - 151
  • [25] RETENTION STUDIES ON MIXED-MODE COLUMNS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WALSHE, M
    KELLY, MT
    SMYTH, MR
    RITCHIE, H
    JOURNAL OF CHROMATOGRAPHY A, 1995, 708 (01) : 31 - 40
  • [26] Mechanistic modeling, simulation, and optimization of mixed-mode chromatography for an antibody polishing step
    Hahn, Tobias
    Geng, Nora
    Petrushevska-Seebach, Katerina
    Dolan, Michael E.
    Scheindel, Marcus
    Graf, Pia
    Takenaka, Kosuke
    Izumida, Kyo
    Li, Lijuan
    Ma, Zijian
    Schuelke, Norbert
    BIOTECHNOLOGY PROGRESS, 2023, 39 (02)
  • [27] Application of a Gradient Retention Model Developed by Using Isocratic Data for the Prediction of Retention, Resolution, and Peak Asymmetry in Ion Chromatography
    Bolanca, Tomislav
    Cerjan-Stefanovic, Stefica
    Ukic, Sime
    Rogosic, Marko
    Lusa, Melita
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (10) : 1373 - 1391
  • [28] Patch controlled protein adsorption in mixed-mode chromatography with benzylamine as functional ligand
    Gao, Dong
    Lin, Dong-Qiang
    Yao, Shan-Jing
    BIOCHEMICAL ENGINEERING JOURNAL, 2008, 38 (03) : 355 - 361
  • [29] Poly(4-vinylpyridine): a polymeric ligand for mixed-mode protein chromatography
    Li, Yanying
    Sun, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1373 : 97 - 105
  • [30] Application of Solvatic Model for Prediction of Retention at Gradient Elution in Reversed-Phase Liquid Chromatography
    Ekmecic, Tina Snoj
    Cigic, Irena Kralj
    ACTA CHIMICA SLOVENICA, 2019, 66 (04) : 958 - 970