Real-time visual biofeedback during weight bearing improves therapy compliance in patients following lower extremity fractures

被引:16
|
作者
Raaben, Marco [1 ]
Holtslag, Herman R. [2 ]
Leenen, Luke P. H. [1 ]
Augustine, Robin [3 ]
Blokhuis, Taco J. [4 ]
机构
[1] Univ Med Ctr Utrecht, Dept Surg, Heidelberglaan 100, NL-3508 GA Utrecht, Netherlands
[2] Acad Med Ctr, Dept Rehabil Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] Uppsala Univ, Dept Engn Sci, Lagerhyddsv 1, SE-75121 Uppsala, Sweden
[4] Maastricht Univ, Dept Surg, Med Ctr, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
关键词
SensiStep; Gait monitoring; Biofeedback; Lower extremity; Weight-bearing; BONE;
D O I
10.1016/j.gaitpost.2017.10.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Individuals with lower extremity fractures are often instructed on how much weight to bear on the affected extremity. Previous studies have shown limited therapy compliance in weight bearing during rehabilitation. In this study we investigated the effect of real-time visual biofeedback on weight bearing in individuals with lower extremity fractures in two conditions: full weight bearing and touch-down weight bearing. Methods: 11 participants with full weight bearing and 12 participants with touch-down weight bearing after lower extremity fractures have been measured with an ambulatory biofeedback system. The participants first walked 15 m and the biofeedback system was only used to register the weight bearing. The same protocol was then repeated with real-time visual feedback during weight bearing. The participants could thereby adapt their loading to the desired level and improve therapy compliance. Results: In participants with full weight bearing, real-time visual biofeedback resulted in a significant increase in loading from 50.9 +/- 7.51% bodyweight (BW) without feedback to 63.2 +/- 6.74% BW with feedback (P=0.0016). In participants with touch-down weight bearing, the exerted lower extremity load decreased from 16.7 +/- 9.77 kg without feedback to 10.27 +/- 4.56 kg with feedback (P=0.0718). More important, the variance between individual steps significantly decreased after feedback (P=0.018). Conclusions: Ambulatory monitoring weight bearing after lower extremity fractures showed that therapy compliance is low, both in full and touch-down weight bearing. Real-time visual biofeedback resulted in significantly higher peak loads in full weight bearing and increased accuracy of individual steps in touch-down weight bearing. Real-time visual biofeedback therefore results in improved therapy compliance after lower extremity fractures.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [41] Clinical application of real-time continuous glucose monitoring system during postoperative enteral nutrition therapy in esophageal cancer patients
    Zhang, Ranran
    Wu, Ying
    Xv, Rui
    Wang, Wei
    Zhang, Lei
    Wang, Ansheng
    Li, Min
    Jiang, Wei
    Jin, Guoxi
    Hu, Xiaolei
    NUTRITION IN CLINICAL PRACTICE, 2024, 39 (04) : 837 - 849
  • [42] Real-Time Tracking of Changes in Respiratory System Impedance During and Immediately Following Methacholine Challenge in Obese Patients: Implications from Modeling
    Peters, U.
    Daphtary, N.
    Kaminsky, D. A.
    Walsh, R.
    MacLean, E.
    Kinsey, C.
    Dixon, A. E.
    Bates, H. T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [43] Efficacy of Real-Time Feedback Exercise Therapy in Patients Following Total Hip Arthroplasty: Protocol for a Pilot Cluster-Randomized Controlled Trial
    Widhalm, Klaus
    Maul, Lukas
    Durstberger, Sebastian
    Putz, Peter
    Leder-Berg, Sebastian
    Kainz, Hans
    Augat, Peter
    JMIR RESEARCH PROTOCOLS, 2024, 13
  • [44] PROSPECTIVE VALIDATION OF ENDOFASTER FOR A REAL-TIME DIAGNOSIS OF H.PYLORI INFECTION DURING UPPER ENDOSCOPY: FOCUS ON PATIENTS IN PPI THERAPY
    Battaglia, E.
    Sguazzini, C.
    Giacobbe, U.
    Niola, P.
    Verna, C.
    Grassini, M.
    DIGESTIVE AND LIVER DISEASE, 2015, 47 : E166 - E166
  • [45] Real-time Classification of Non-Weight Bearing Lower-Limb Movements Using EMG to Facilitate Phantom Motor Execution: Engineering and Case Study Application on Phantom Limb Pain
    Lendaro, Eva
    Mastinu, Enzo
    Hakansson, Bo
    Ortiz-Catalan, Max
    FRONTIERS IN NEUROLOGY, 2017, 8
  • [46] Use of Real-Time Continuous Glucose Monitoring Improves Glycemic Control and Other Clinical Outcomes in Type 2 Diabetes Patients Treated with Less Intensive Therapy
    Grace, Thomas
    Salyer, Jay
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (01) : 26 - 31
  • [47] Real-time and competitive RT-PCR quantification of BCR-ABL transcripts in CML patients during alpha-IFN therapy
    Martinelli, G
    Giannini, B
    Amabile, M
    Testoni, N
    de Vivo, A
    Bonifazi, F
    Ottaviani, E
    Saglio, G
    Terragna, C
    Buonamici, S
    Soverini, S
    Trabacchi, E
    Bassi, S
    Rosti, G
    Baccarani, M
    Tura, S
    BONE MARROW TRANSPLANTATION, 2001, 27 : S142 - S142
  • [48] Use of real-time quantitative polymerase chain reaction to monitor the evolution of Brucella melitensis DNA load during therapy and post-therapy follow-up in patients with brucellosis
    Navarro, E
    Segura, JC
    Castaño, MJ
    Solera, J
    CLINICAL INFECTIOUS DISEASES, 2006, 42 (09) : 1266 - 1273
  • [49] Detection of Circulating Tumor Cells in Peripheral Blood of Breast Cancer Patients During or After Therapy Using a Multigene Real-Time RT-PCR Assay
    Barbara K. Zehentner
    Heather Secrist
    Dawn C. Hayes
    Xinqun Zhang
    Richard C. Ostenson
    Steven Loop
    Gary Goodman
    Raymond L. Houghton
    David H. Persing
    Molecular Diagnosis & Therapy, 2006, 10 : 41 - 47
  • [50] Detection of circulating tumor cells in peripheral blood of breast cancer patients during or after therapy using a multigene real-time RT-PCR assay
    Zehentner, Barbara K.
    Secrist, Heather
    Hayes, Dawn C.
    Zhang, Xinqun
    Ostenson, Richard C.
    Loop, Steven
    Goodman, Gary
    Houghton, Raymond L.
    Persing, David H.
    MOLECULAR DIAGNOSIS & THERAPY, 2006, 10 (01) : 41 - 47