Real-time visual biofeedback during weight bearing improves therapy compliance in patients following lower extremity fractures

被引:16
|
作者
Raaben, Marco [1 ]
Holtslag, Herman R. [2 ]
Leenen, Luke P. H. [1 ]
Augustine, Robin [3 ]
Blokhuis, Taco J. [4 ]
机构
[1] Univ Med Ctr Utrecht, Dept Surg, Heidelberglaan 100, NL-3508 GA Utrecht, Netherlands
[2] Acad Med Ctr, Dept Rehabil Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] Uppsala Univ, Dept Engn Sci, Lagerhyddsv 1, SE-75121 Uppsala, Sweden
[4] Maastricht Univ, Dept Surg, Med Ctr, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
关键词
SensiStep; Gait monitoring; Biofeedback; Lower extremity; Weight-bearing; BONE;
D O I
10.1016/j.gaitpost.2017.10.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Individuals with lower extremity fractures are often instructed on how much weight to bear on the affected extremity. Previous studies have shown limited therapy compliance in weight bearing during rehabilitation. In this study we investigated the effect of real-time visual biofeedback on weight bearing in individuals with lower extremity fractures in two conditions: full weight bearing and touch-down weight bearing. Methods: 11 participants with full weight bearing and 12 participants with touch-down weight bearing after lower extremity fractures have been measured with an ambulatory biofeedback system. The participants first walked 15 m and the biofeedback system was only used to register the weight bearing. The same protocol was then repeated with real-time visual feedback during weight bearing. The participants could thereby adapt their loading to the desired level and improve therapy compliance. Results: In participants with full weight bearing, real-time visual biofeedback resulted in a significant increase in loading from 50.9 +/- 7.51% bodyweight (BW) without feedback to 63.2 +/- 6.74% BW with feedback (P=0.0016). In participants with touch-down weight bearing, the exerted lower extremity load decreased from 16.7 +/- 9.77 kg without feedback to 10.27 +/- 4.56 kg with feedback (P=0.0718). More important, the variance between individual steps significantly decreased after feedback (P=0.018). Conclusions: Ambulatory monitoring weight bearing after lower extremity fractures showed that therapy compliance is low, both in full and touch-down weight bearing. Real-time visual biofeedback resulted in significantly higher peak loads in full weight bearing and increased accuracy of individual steps in touch-down weight bearing. Real-time visual biofeedback therefore results in improved therapy compliance after lower extremity fractures.
引用
下载
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [21] Real-Time Digital Feedback for Exercise Therapy of Lower Extremity Functional Deficits: A Mixed Methods Study of User Requirements
    Widhalm K.
    Maul L.
    Durstberger S.
    Klupper C.
    Putz P.
    Studies in Health Technology and Informatics, 2023, 301 : 108 - 114
  • [22] Real-time visual feedback during training improves laypersons' CPR quality: a randomized controlled manikin study
    Baldi, Enrico
    Cornara, Stefano
    Contri, Enrico
    Epis, Francesco
    Fina, Dario
    Zelaschi, Beatrice
    Dossena, Cinzia
    Fichtner, Ferdinando
    Tonani, Michela
    DiMaggio, Marzia
    Zambaiti, Elisa
    Somaschini, Alberto
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2017, 19 (06) : 480 - 487
  • [23] Observing real-time images during ultrasound-guided procedures improves patients' experience
    Sahbudin, Ilfita
    Bell, Jason
    Kumar, Kanta
    Raza, Karim
    Filer, Andrew
    RHEUMATOLOGY, 2016, 55 (03) : 585 - 586
  • [24] Kinect-based real-time audiovisual feedback device improves CPR quality of lower-body-weight rescuers
    Wang, Jen-Chun
    Tsai, Shih-Hung
    Chen, Ying-Hsin
    Chen, Yu-Long
    Chu, Shi-Jye
    Liao, Wen-I
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (04): : 577 - 582
  • [25] WEIGHT-BEARING MRI: COMPARISON OF KNEE ANGLE SET-UP METHODS AND THE EFFECT OF REAL-TIME VISUAL FEEDBACK
    Dubowsky, Sarah R.
    Allen, Jerome
    Gade, Venkata
    Barrance, Peter J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 617 - 618
  • [26] Scintillation Dots for Real-Time Visual Tracking of the IIDR Source as a QA Process During Skin Therapy
    Huynh, E.
    Devlin, P.
    Buzurovic, I.
    Cormack, R.
    Harris, T.
    O'Farrell, D.
    Bhagwat, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E574 - E574
  • [27] Real-Time Visual Kinematic Feedback During Overground Walking Improves Gait Biomechanics in Individuals Post-Stroke
    Hinton, Erica H.
    Buffum, Russell
    Kingston, David
    Stergiou, Nick
    Kesar, Trisha
    Bierner, Samuel
    Knarr, Brian A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (02) : 355 - 363
  • [28] Real-Time Visual Kinematic Feedback During Overground Walking Improves Gait Biomechanics in Individuals Post-Stroke
    Erica H. Hinton
    Russell Buffum
    David Kingston
    Nick Stergiou
    Trisha Kesar
    Samuel Bierner
    Brian A. Knarr
    Annals of Biomedical Engineering, 2024, 52 : 355 - 363
  • [29] A Tailored Music-Motor Therapy and Real-Time Biofeedback Mobile Phone App ('GotRhythm') to Promote Rehabilitation Following Stroke: A Pilot Study
    Hankinson, Katherine
    Shaykevich, Alex
    Vallence, Ann-Maree
    Rodger, Jennifer
    Rosenberg, Michael
    Etherton-Beer, Christopher
    NEUROSCIENCE INSIGHTS, 2022, 17
  • [30] Effects of the real-time feedback and knee taping on lower-extremity function during ergometer pedaling in subjects with tibiofemoral varus alignment
    Hatefi, Mohamadreza
    Hadadnezhad, Malihe
    Shojaedin, Sadredin
    Babakhani, Farideh
    Tazji, Mehdi Khaleghi
    GAIT & POSTURE, 2022, 96 : 322 - 329