Measuring defibrillator surface potentials: The validation of a predictive defibrillation computer model

被引:5
|
作者
Tate, Jess [1 ,2 ]
Stinstra, Jeroen [1 ,2 ]
Pilcher, Thomas [3 ]
Poursaid, Ahrash [1 ,2 ]
Jolley, Matthew A. [4 ]
Saarel, Elizabeth [3 ]
Triedman, John [5 ]
MacLeo, Rob S. [1 ,2 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT USA
[3] Univ Utah, Div Pediat Cardiol, Salt Lake City, UT USA
[4] Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Philadelphia, PA 19104 USA
[5] Childrens Hosp Boston, Dept Cardiol, Boston, MA USA
基金
美国国家卫生研究院;
关键词
Defibrillation; Patient-specific modeling; Limited lead selection; Body surface mapping; Defibrillation threshold; Defibrillation modeling; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HIGH-RISK; MYOCARDIAL-INFARCTION; LEAD SELECTION; CHILDREN; INSIGHTS; DISEASE; HEART; MAPS;
D O I
10.1016/j.compbiomed.2018.08.025
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Implantable cardioverter defibrillators (ICDs) are commonly used to reduce the risk in patients with life threatening arrhythmias, however, clinicians have little systematic guidance to place the device, especially in cases of unusual anatomy. We have previously developed a computational model that evaluates the efficacy of a delivered shock as a clinical and research aid to guide ICD placement on a patient specific basis. We report here on progress to validate this model with measured ICD surface potential maps from patients undergoing ICD implantation and testing for defibrillation threshold (DFT). We obtained body surface potential maps of the defibrillation pulses by adapting a limited lead selection and potential estimation algorithm to deal with the limited space for recording electrodes. Comparison of the simulated and measured potential maps of the defibrillation shock yielded similar patterns, a typical correlation greater than 0.9, and a relative error less than 15%. Comparison of defibrillation thresholds also showed accurate prediction of the simulations. The high agreement of the potential maps and DFTs suggests that the predictive simulation generates realistic potential values and can accurately predict DFTs in patients. These validation results pave the way for use of this model in optimization studies prior to device implantation.
引用
收藏
页码:402 / 410
页数:9
相关论文
共 50 条
  • [41] Model predictive control relevant identification and validation
    Huang, B
    Malhotra, A
    Tamayo, EC
    CHEMICAL ENGINEERING SCIENCE, 2003, 58 (11) : 2389 - 2401
  • [42] Development and validation of a predictive model for the pedestal height
    Snyder, P. B.
    Groebner, R. J.
    Leonard, A. W.
    Osborne, T. H.
    Wilson, H. R.
    PHYSICS OF PLASMAS, 2009, 16 (05)
  • [43] On the problem of model validation for predictive exposure assessments
    M. B. Beck
    J. R. Ravetz
    L. A. Mulkey
    T. O. Barnwell
    Stochastic Hydrology and Hydraulics, 1997, 11 : 229 - 254
  • [44] Establishment and validation of predictive model of prostate cancer
    Zhang, Chen
    Hu, Wentao
    Li, Dengke
    Tang, Huarui
    Zhang, Lulu
    Su, Fu
    Tao, Jianping
    Zhao, Lunjie
    Gao, Yukui
    Cheng, Qingshui
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [45] EXPERIMENTAL VALIDATION OF A PREDICTIVE PYROLYSIS MODEL IN ASPENPLUS®
    Peters, Jens F.
    Banks, Scott W.
    Susmozas, Ana
    Dufour, Javier
    PAPERS OF THE 22ND EUROPEAN BIOMASS CONFERENCE: SETTING THE COURSE FOR A BIOBASED ECONOMY, 2014, : 1160 - 1163
  • [46] Validation of a predictive model for individualizing clozapine dose
    Rostami-Hodjegan, A
    Ros, JE
    van der Weide, J
    Flanagan, RJ
    Lennard, M
    Tucker, GT
    JOURNAL OF PSYCHOPHARMACOLOGY, 2003, 17 (03) : A54 - A54
  • [47] Dominant frequency maps of epicardial and body surface potentials during ventricular fibrillation - a computer model study
    Nowak, C. N.
    Wieser, L.
    Fischer, G.
    Tilg, B.
    Strohmenger, H. U.
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 47 - +
  • [48] MEASURING THE QUALITY OF COMPUTER-MODEL PERFORMANCE
    OLEARY, DE
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 1992, 56 (03) : 319 - 331
  • [49] Influence of polarity reversal on defibrillation success with biphasic shocks and a transvenous/subcutaneous defibrillator system in a porcine animal model
    Stellbrink, C
    Schauerte, P
    Loeser, H
    Rosenbaum, C
    Kuckertz, E
    Vogel, M
    Messmer, BJ
    Hanrath, P
    Schoendube, FA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07): : 1435 - 1441