Influence of polarity reversal on defibrillation success with biphasic shocks and a transvenous/subcutaneous defibrillator system in a porcine animal model

被引:1
|
作者
Stellbrink, C
Schauerte, P
Loeser, H
Rosenbaum, C
Kuckertz, E
Vogel, M
Messmer, BJ
Hanrath, P
Schoendube, FA
机构
[1] RWTH Aachen, Med Clin 1, Aachen, Germany
[2] RWTH Aachen, Dept Thorac & Cardiovasc Surg, Aachen, Germany
来源
关键词
defibrillation; polarity; implantable defibrillator;
D O I
10.1111/j.1540-8159.1998.tb00215.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Clinical studies show that polarity reversal affects defibrillation success in transvenous monophasic defibrillators. Current devices use biphasic shocks for defibrillation. We investigated in a porcine animal model whether polarity reversal influences defibrillation success with biphasic shocks. In nine anesthetized, ventilated pigs, the defibrillation efficacy of biphasic shocks (14.3 ms and 10.8 ms pulse duration) with "initial polarity" (IP, distal electrode = cathode) and "reversed polarity" (RP, distal electrode = anode) delivered via a transvenous/subcutaneous lead system was compared. Voltage and current of each defibrillating pulse were recorded on an oscilloscope and impedance calculated as voltage divided by current. Cumulative defibrillation success was significantly higher for RP than for ITP for both pulse durations (55% vs 44%, P = 0.019) for 14.3 ms (57% vs 45%, P < 0.05) and insignificantly higher for 10.8 ms (52 % vs 42 %, P = n.s.). Impedance was significantly lower with RP at the trailing edge of pulse 1 (IP: 44 +/- 8.4 vs RP: 37 +/- 9.3 with 14.3 ms, P < 0.001 and IP: 44 +/- 6.2 vs RP: 41 +/- 7.6 Ohm with 10.8 ms, P < 0.001) and the leading edge of pulse 2 (IP: 37 +/- 5 vs RP: 35 +/- 4.2 Ohm with 14.3 ms, P = 0.05 and IF: 37.5 +/- 3.7 vs RP: 36 +/- 5 Ohm with 10.8 ms, P = 0.02). In conclusion, in this animal model, internal defibrillation using the distal coil as anode results in higher defibrillation efficacy than using the distal coil as cathode. Calculated impedances show different courses throughout the shock pulses suggesting differences in current flow during the shock.
引用
收藏
页码:1435 / 1441
页数:7
相关论文
共 11 条
  • [1] Polarity reversal improves defibrillation efficacy in patients undergoing transvenous cardioverter defibrillator implantation with biphasic shocks
    Schauerte, P
    Stellbrink, C
    Schondube, FA
    Loser, H
    Haltern, G
    Messmer, BJ
    Hanrath, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02): : 301 - 306
  • [2] THE EFFECT OF POLARITY REVERSAL ON BIPHASIC DEFIBRILLATION THRESHOLD WITH AN INTEGRATED TRANSVENOUS LEAD SYSTEM
    SHOROFSKY, SR
    FOSTER, AH
    GOLD, MR
    CIRCULATION, 1994, 90 (04) : 228 - 228
  • [3] EFFECT OF FIRST-PHASE POLARITY OF BIPHASIC SHOCKS ON DEFIBRILLATION THRESHOLD WITH A SINGLE TRANSVENOUS LEAD SYSTEM
    STRICKBERGER, SA
    MAN, KC
    DAOUD, E
    NEARY, MP
    HORWOOD, LE
    NIEBAUER, M
    HUMMEL, JD
    MORADY, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) : 1605 - 1608
  • [4] Optimized pulse durations minimize the effect of polarity reversal on defibrillation efficacy with biphasic shocks
    Schauerte, P
    Schöndube, FA
    Grossmann, M
    Messmer, BJ
    Hanrath, P
    Stellbrink, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (05): : 790 - 797
  • [5] Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system
    Usui, M
    Walcott, GP
    Strickberger, SA
    Rollins, DL
    Smith, WM
    Ideker, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (01): : 65 - 71
  • [6] Atrial defibrillation success comparing a novel passive implantable atrial defibrillator with a routine transvenous atrial defibrillation system
    Manoharan, G
    Evans, N
    Allen, JD
    Anderson, J
    Adgey, AAJ
    EUROPEAN HEART JOURNAL, 2000, 21 : 558 - 558
  • [7] EFFECTS OF BIPHASIC SHOCKS ON ELECTROGRAM AMPLITUDES USING A NEW INTEGRATED BIPOLAR TRANSVENOUS DUAL-CHAMBER DEFIBRILLATOR ELECTRODE SYSTEM
    JUNG, W
    MANZ, M
    ACCORTI, P
    MOOSDORF, R
    PIEL, M
    BAUER, T
    KORTE, T
    LUDERITZ, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A420 - A420
  • [8] Current is better than energy as predictor of success for biphasic defibrillatory shocks in a porcine model of ventricular fibrillation
    Ristagno, Giuseppe
    Yu, Tao
    Quan, Weilun
    Freeman, Gary
    Li, Yongqin
    RESUSCITATION, 2013, 84 (05) : 678 - 683
  • [9] Subcutaneous cardioverter defibrillator has longer time to therapy but is less cardiotoxic than transvenous cardioverter defibrillator. Study carried out in a preclinical porcine model
    Garcia, Rodrigue
    Inal, Sofiane
    Favreau, Frederic
    Jayle, Christophe
    Hauet, Thierry
    Bruneval, Patrick
    Kerforne, Thomas
    Hajj-Chahine, Jamil
    Degand, Bruno
    EUROPACE, 2018, 20 (05): : 873 - 879
  • [10] Leakage of energy to the body surface during defibrillation shock by an implantable cardioverter-defibrillator (TCD) system - Experimental evaluation during defibrillation shocks through the right ventricular lead and the subcutaneous active-can in canines
    Niwano, S
    Kitano, Y
    Moriguchi, M
    Yoshizawa, N
    Kashiwa, T
    Suyama, M
    Toyoshima, T
    Izumi, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (03): : 219 - 225