Feasibility of using single photon counting X-ray for lung tumor position estimation based on 4D-CT

被引:6
|
作者
Aschenbrenner, Katharina P. [1 ,2 ]
Guthier, Christian V. [1 ]
Lyatskaya, Yulia [3 ,4 ]
Boda-Heggemann, Judit [5 ]
Wenz, Frederik [5 ]
Hesser, Juergen W. [1 ,2 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Dept Expt Radiat Oncol, Mannheim, Germany
[2] Heidelberg Univ, IWR, Heidelberg, Germany
[3] Brigham & Womens Ctr, Boston, MA USA
[4] Harvard Med Sch, Boston, MA USA
[5] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2017年 / 27卷 / 03期
关键词
Ultra low dose; KV imaging; Lung tumor; Maximum likelihood; Poisson distribution; Correlation coefficient; Template matching; STEREOTACTIC ABLATIVE RADIOTHERAPY; MOTION COMPENSATION; FIDUCIAL MARKERS; IMAGE DATA; TRACKING; CANCER; ALGORITHM; RECONSTRUCTION; NONLINEARITY; REGISTRATION;
D O I
10.1016/j.zemedi.2017.05.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In stereotactic body radiation therapy of lung tumors, reliable position estimation of the tumor is necessary in order to minimize normal tissue complication rate. While kV X-ray imaging is frequently used, continuous application during radiotherapy sessions is often not possible due to concerns about the additional dose. Thus, ultra low-dose (ULD) kV X-ray imaging based on a single photon counting detector is suggested. This paper addresses the lower limit of photons to locate the tumor reliably with an accuracy in the range of state-of-the-art methods, i.e. a few millimeters. Method: 18 patient cases with four dimensional CT (4D CT), which serves as a-priori information, are included in the study. ULD cone beam projections are simulated from the 4D-CTs including Poisson noise. The projections from the breathing phases which correspond to different tumor positions are compared to the ULD projection by means of Poisson log-likelihood (PML) and correlation coefficient (CC), and template matching under these metrics. Results: The results indicate that in full thorax imaging five photons per pixel suffice for a standard deviation in tumor positions of less than half a breathing phase. Around 50 photons per pixel are needed to achieve this accuracy with the field of view restricted to the tumor region. Compared to CC, PML tends to perform better for low photon counts and shifts in patient setup. Template matching only improves the position estimation in high photon counts. The quality of the reconstruction is independent of the projection angle. Conclusions: The accuracy of the proposed ULD single photon counting system is in the range of a few millimeters and therefore comparable to state-of-the-art tumor tracking methods. At the same time, a reduction in photons per pixel by three to four orders of magnitude relative to commercial systems with flatpanel detectors can be achieved. This enables continuous kV image-based position estimation during all fractions since the additional dose to the patient is negligible.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 50 条
  • [31] Single-step phase contrast x-ray imaging using photon counting detectors
    Guersoy, Doga
    Das, Mini
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [32] An X-Ray Based Capsule for Colorectal Cancer Screening incorporating Single Photon Counting Technology
    Lifshitz, Ronen
    Kimchy, Yoav
    Gelbard, Nir
    Leibushor, Avi
    Golan, Oleg
    Elgali, Avner
    Hassoon, Salah
    Kaplan, Max
    Smirnov, Michael
    Shpigelman, Boaz
    Bar-Ilan, Omer
    Rubin, Daniel
    Ovadia, Alex
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [33] An Effective Deep Learning Framework for Lung Tumor Segmentation in 4D-CT
    Momin, S.
    Lei, Y.
    Tian, Z.
    Wang, T.
    Roper, J.
    Kesarwala, A.
    Higgins, K.
    Bradley, J.
    Liu, T.
    Yang, X.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] X-ray Photon Counting and Two-Color X-ray Imaging Using Indirect Detection
    Dierickx, Bart
    Yao, Qiang
    Witvrouwen, Nick
    Uwaerts, Dirk
    Vandewiele, Stijn
    Gao, Peng
    SENSORS, 2016, 16 (06)
  • [35] Spectral response compensation for photon-counting clinical x-ray CT using sinogram restoration
    Srivastava, Somesh
    Cammin, Jochen
    Fung, George S. K.
    Tsui, Benjamin M. W.
    Taguchi, Katsuyuki
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [36] Motion correction for robot-based X-ray photon-counting CT at ultrahigh resolution
    Li, Mengzhou
    Bohacova, Jana
    Uher, Josef
    Cong, Wenxiang
    Rubinstein, Jay
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [37] A neural network-based method for spectral distortion correction in photon counting x-ray CT
    Touch, Mengheng
    Clark, Darin P.
    Barber, William
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (16): : 6132 - 6153
  • [38] Feasibility of improving image performance in photon-counting computed tomography using X-ray spectrum filtration
    Lee, Soohyun
    Lee, Minjae
    Cho, Hyosung
    JOURNAL OF INSTRUMENTATION, 2024, 19 (03):
  • [39] DETECTION OF LUNG INJURY USING 4D-CT CHEST IMAGES
    Soliman, Ahmed
    Khalifa, Fahmi
    Shaffie, Ahmed
    Dunlap, Neal
    Wang, Brian
    Elmaghraby, Adel
    El-Baz, Ayman
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1274 - 1277
  • [40] EIGER: Next generation single photon counting detector for X-ray applications
    Dinapoli, Roberto
    Bergamaschi, Anna
    Henrich, Beat
    Horisberger, Roland
    Johnson, Ian
    Mozzanica, Aldo
    Schmid, Elmar
    Schmitt, Bernd
    Schreiber, Akos
    Shi, Xintian
    Theidel, Gerd
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 79 - 83