Feasibility of using single photon counting X-ray for lung tumor position estimation based on 4D-CT

被引:6
|
作者
Aschenbrenner, Katharina P. [1 ,2 ]
Guthier, Christian V. [1 ]
Lyatskaya, Yulia [3 ,4 ]
Boda-Heggemann, Judit [5 ]
Wenz, Frederik [5 ]
Hesser, Juergen W. [1 ,2 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Dept Expt Radiat Oncol, Mannheim, Germany
[2] Heidelberg Univ, IWR, Heidelberg, Germany
[3] Brigham & Womens Ctr, Boston, MA USA
[4] Harvard Med Sch, Boston, MA USA
[5] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2017年 / 27卷 / 03期
关键词
Ultra low dose; KV imaging; Lung tumor; Maximum likelihood; Poisson distribution; Correlation coefficient; Template matching; STEREOTACTIC ABLATIVE RADIOTHERAPY; MOTION COMPENSATION; FIDUCIAL MARKERS; IMAGE DATA; TRACKING; CANCER; ALGORITHM; RECONSTRUCTION; NONLINEARITY; REGISTRATION;
D O I
10.1016/j.zemedi.2017.05.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In stereotactic body radiation therapy of lung tumors, reliable position estimation of the tumor is necessary in order to minimize normal tissue complication rate. While kV X-ray imaging is frequently used, continuous application during radiotherapy sessions is often not possible due to concerns about the additional dose. Thus, ultra low-dose (ULD) kV X-ray imaging based on a single photon counting detector is suggested. This paper addresses the lower limit of photons to locate the tumor reliably with an accuracy in the range of state-of-the-art methods, i.e. a few millimeters. Method: 18 patient cases with four dimensional CT (4D CT), which serves as a-priori information, are included in the study. ULD cone beam projections are simulated from the 4D-CTs including Poisson noise. The projections from the breathing phases which correspond to different tumor positions are compared to the ULD projection by means of Poisson log-likelihood (PML) and correlation coefficient (CC), and template matching under these metrics. Results: The results indicate that in full thorax imaging five photons per pixel suffice for a standard deviation in tumor positions of less than half a breathing phase. Around 50 photons per pixel are needed to achieve this accuracy with the field of view restricted to the tumor region. Compared to CC, PML tends to perform better for low photon counts and shifts in patient setup. Template matching only improves the position estimation in high photon counts. The quality of the reconstruction is independent of the projection angle. Conclusions: The accuracy of the proposed ULD single photon counting system is in the range of a few millimeters and therefore comparable to state-of-the-art tumor tracking methods. At the same time, a reduction in photons per pixel by three to four orders of magnitude relative to commercial systems with flatpanel detectors can be achieved. This enables continuous kV image-based position estimation during all fractions since the additional dose to the patient is negligible.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 50 条
  • [11] A high efficiency single photon counting silicon matrix for position sensitive X-ray detection
    Arfelli, F
    Bonvicini, V
    Bravin, A
    Cantatore, G
    Castelli, E
    Dalla Palma, L
    Di Michiel, M
    Longo, R
    Olivo, A
    Pani, S
    Pontoni, D
    Poropat, P
    Prest, M
    Rashevsky, A
    Tromba, G
    Vacchi, A
    Vallazza, E
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 304 - 307
  • [12] Scanning X-ray Microscopy with a Single Photon Counting 2D Detector
    Stachnik, K.
    Meents, A.
    ACTA PHYSICA POLONICA A, 2014, 125 (04) : 902 - 906
  • [13] Eiger: a single-photon counting x-ray detector
    Johnson, I.
    Bergamaschi, A.
    Billich, H.
    Cartier, S.
    Dinapoli, R.
    Greiffenberg, D.
    Guizar-Sicairos, M.
    Henrich, B.
    Jungmann, J.
    Mezza, D.
    Mozzanica, A.
    Schmitt, B.
    Shi, X.
    Tinti, G.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [14] Calibration of single-photon counting X-ray CCD
    Zhang, Shuang-Gen
    Huang, Wen-Zhong
    Gu, Yu-Qiu
    Jiang, Gang
    Xiong, Yong
    Wen, Xian-Lun
    Wang, Guang-Chang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2006, 18 (01): : 77 - 80
  • [15] Estimation of an Atomic Density with a Singular Value Decomposition Method. Using a Photon-Counting X-ray CT
    Ito, Ryo
    Ogawa, Koichi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [16] X-ray photon counting detector for x-ray pulsar-based navigation
    Hu Hui-Jun
    Zhao Bao-Sheng
    Sheng Li-Zhi
    Yan Qiu-Rong
    Chen Bao-Mei
    Wang Peng
    ACTA PHYSICA SINICA, 2012, 61 (01)
  • [17] Photon Counting X-Ray Detectors and DR and CT Imaging Methods
    Taguchi, K.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [18] Subpicosecond hard x-ray streak camera using single-photon counting
    Enquist, Henrik
    Navirian, Hengameh
    Nuske, Ralf
    Schmising, Clemens von Korff
    Jurgilaitis, Andrius
    Herzog, Marc
    Bargheer, Matias
    Sondhauss, Peter
    Larsson, Jorgen
    OPTICS LETTERS, 2010, 35 (19) : 3219 - 3221
  • [19] Quality of X-ray transmission radiography based on single photon counting pixel device
    Jakubek, J
    Vavrik, D
    Pospisil, S
    Uher, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 113 - 117
  • [20] Analysis of artifact with X-ray CT using energy band by photon counting CdTe detector
    Matsumoto, G.
    Imura, Y.
    Morii, H.
    Miyake, A.
    Aoki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 292 - 294