Q-band EPR biodosimetry in tooth enamel microsamples: Feasibility test and comparison with X-band

被引:29
|
作者
Romanyukha, A.
Mitchell, C. A.
Schauer, D. A.
Romanyukha, L.
Swartz, H. M.
机构
[1] Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
[2] Natl Council Radiat Protect & Measurements, Bethesda, MD 20814 USA
[3] Dartmouth Med Sch, Hanover, NH 03755 USA
来源
HEALTH PHYSICS | 2007年 / 93卷 / 06期
关键词
dose assessment; electromagnetic fields; detection; limits; emergency planning;
D O I
10.1097/01.HP.0000269507.08343.85
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A comparative study of electron paramagnetic resonance dosimetry in Q- and X-bands has shown that Q-band is able to provide accurate measurements of radiation doses even below 0.5 Gy with tooth enamel samples as small as 2 mg. The optimal amount of tooth enamel for dose measurements in Q-band was found to be 4 mg. This is less than 1 % of the total amount of tooth enamel in one molar tooth. Such a small amount of tooth enamel can be harmlessly obtained in an emergency requiring after-the-fact radiation dose measurement. The other important advantage of Q-band is full resolution of the radiation-induced EPR signal from the native, background signal. This separation makes dose response measurements much easier in comparison to conventional X-band measurements in which these overlapping signals necessitate special methods for doses below 0.5 Gy. The main disadvantages of Q-band measurements are a higher level of noise and lower spectral reproducibility than in X-band. The effect of these negative factors on the precision of dose measurements in Q-band could probably be reduced by improvement of sample fixation in the resonance cavity and better optimization of signal filtration to reduce high-frequency noise.
引用
收藏
页码:631 / 635
页数:5
相关论文
共 50 条
  • [41] ELECTRON-SPIN RESONANCE SPECTROSCOPY STUDY OF SOLVATED ALKALI-METAL ATOMS AT X-BAND AND Q-BAND FREQUENCIES
    GUY, SC
    EDWARDS, PP
    CATTERALL, R
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1984, 80 : 1539 - 1554
  • [42] EPR-correlated dipolar spectroscopy by Q-band chirp SIFTER
    Doll, Andrin
    Jeschke, Gunnar
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2016, 18 (33) : 23111 - 23120
  • [43] STUDIES ON HUMAN UTERINE CERVIX AND RAT UTERUS USING S-BAND, X-BAND AND Q-BAND ELECTRON-SPIN-RESONANCE SPECTROSCOPY
    TOMASI, A
    BENEDETTO, C
    NILGES, M
    SLATER, F
    SWARTZ, HM
    SYMONS, MCR
    BIOCHEMICAL JOURNAL, 1984, 224 (02) : 431 - 436
  • [44] Effect of the tooth surface water on the accuracy of dose reconstructions in the X-band in vivo EPR dosimetry
    Zou, Jierui
    Guo, Junwang
    Dong, Guofu
    Ma, Lei
    Cong, Jianbo
    Liu, Ye
    Tian, Ye
    Wu, Ke
    APPLIED RADIATION AND ISOTOPES, 2018, 139 : 86 - 90
  • [45] UNIAXIAL STRESS APPARATUS FOR AN EPR X-BAND SPECTROMETER
    SZUMOWSKI, J
    FALKOWSKI, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (02): : 252 - 253
  • [46] An X-Band Crossed-Loop EPR Resonator
    George A. Rinard
    Richard W. Quine
    Joseph McPeak
    Laura Buchanan
    Sandra S. Eaton
    Gareth R. Eaton
    Applied Magnetic Resonance, 2017, 48 : 1219 - 1226
  • [47] SURFACE DIELECTRIC RESONATORS FOR X-BAND EPR SPECTROSCOPY
    Petryakov, Sergey V.
    Schreiber, Wilson
    Kmiec, Maciej M.
    Williams, Benjamin B.
    Swartz, Harold M.
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (1-3) : 127 - 132
  • [48] X-band EPR Spectroscopic Investigation of Seborrheic Keratosis
    Kouichi Nakagawa
    Satoko Minakawa
    Daisuke Sawamura
    Analytical Sciences, 2019, 35 : 1027 - 1030
  • [49] An X-Band Crossed-Loop EPR Resonator
    Rinard, George A.
    Quine, Richard W.
    McPeak, Joseph
    Buchanan, Laura
    Eaton, Sandra S.
    Eaton, Gareth R.
    APPLIED MAGNETIC RESONANCE, 2017, 48 (11-12) : 1219 - 1226
  • [50] X-band EPR Spectroscopic Investigation of Seborrheic Keratosis
    Nakagawa, Kouichi
    Minakawa, Satoko
    Sawamura, Daisuke
    ANALYTICAL SCIENCES, 2019, 35 (09) : 1027 - 1030