Polycapillary lenses for soft x-ray transmission in ITER: Model, comparison with experiments, and potential application

被引:3
|
作者
Mazon, D. [1 ]
Liegeard, C. [2 ]
Jardin, A. [1 ]
Barnsley, R. [3 ]
Walsh, M. [3 ]
O'Mullane, M. [4 ]
Sirinelli, A. [3 ]
Dorchies, F. [5 ]
机构
[1] CEA, IRFM, F-13108 St Paul Les Durance, France
[2] Ecole Polytech Paris, Paris, France
[3] ITER Org, St Paul Les Durance, France
[4] Univ Strathclyde, Dept Phys SUPA, Glasgow G4 0NG, Lanark, Scotland
[5] Univ Bordeaux, CNRS, CEA, CELIA,UMR5107, F-33405 Talence, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 11期
基金
欧盟地平线“2020”;
关键词
OPTICS;
D O I
10.1063/1.4958942
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measuring Soft X-Ray (SXR) radiation [0.1 keV; 15 keV] in tokamaks is a standard way of extracting valuable information on the particle transport and magnetohydrodynamic activity. Generally, the analysis is performed with detectors positioned close to the plasma for a direct line of sight. A burning plasma, like the ITER deuterium-tritium phase, is too harsh an environment to permit the use of such detectors in close vicinity of the machine. We have thus investigated in this article the possibility of using polycapillary lenses in ITER to transport the SXR information several meters away from the plasma in the complex port-plug geometry. Published by AIP Publishing.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Development of Fluorescence XAFS System in Soft X-Ray Region Toward Operando Conditions Using Polycapillary X-Ray Lens
    Honda, Mitsunori
    Shimoyama, Iwao
    Baba, Yuji
    Suzuki, Shinichi
    Okamoto, Yoshihiro
    Yaita, Tsuyoshi
    [J]. E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2016, 14 : 35 - 38
  • [42] Magnetic soft X-ray transmission microscopy
    Fischer, P
    [J]. CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2003, 7 (02): : 173 - 179
  • [43] Soft x-ray multilayer beamsplitter for x-ray laser application
    Tang, H
    Yi, K
    Fan, Z
    Gu, Y
    Wang, S
    [J]. X-RAY LASERS 1998, 1999, 159 : 613 - 614
  • [44] Polycapillary x-ray lenses for single-shot, laser-driven powder diffraction
    Schollmeier, M.
    Ao, T.
    Field, E. S.
    Galloway, B. R.
    Kalita, P.
    Kimmel, M. W.
    Morgan, D. V.
    Rambo, P. K.
    Schwarz, J.
    Shores, J. E.
    Smith, I. C.
    Speas, C. S.
    Benage, J. F.
    Porter, J. L.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [45] X-ray transmission characteristics and potential communication application in plasma region
    Li Yao
    Su Tong
    Lei Fan
    Xu Neng
    Sheng Li-Zhi
    Zhao Bao-Sheng
    [J]. ACTA PHYSICA SINICA, 2019, 68 (04)
  • [46] Application of Polycapillary Optics to X-ray Fluorescence for Advanced Spectroscopy and Microscopy Studies
    Guglielmotti, V
    Hampai, D.
    Micheli, L.
    Mazzuca, C.
    Redi, M.
    Gasbarri, E.
    Dabagov, S. B.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XV, 2020, 11491
  • [47] X-ray Transmission Characteristics Measurement of a Polycapillary Lens Installed in an Analytical Electron Microscope
    Takano, Akira
    Maehata, Keisuke
    Iyomoto, Naoko
    Hara, Tom
    Mitsuda, Kazuhisa
    Yamasaki, Noriko
    Tanaka, Keiichi
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [48] Application of Confocal Technology Based on Polycapillary X-Ray Lens in Measuring Thickness
    Peng Song
    Liu Zhi-guo
    Sun Tian-xi
    Li Yu-de
    Liu He-he
    Zhao Wei-gang
    Zhao Guang-cui
    Lin Xiao-yan
    Luo Ping
    Pan Qiu-li
    Ding Xun-liang
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (08) : 2223 - 2226
  • [49] Vacuum photodiode detectors for soft x-ray ITER plasma tomography
    Gott, YV
    Stepanenko, MM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (07):
  • [50] ITER-relevant calibration technique for soft x-ray spectrometer
    Rzadkiewicz, J.
    Ksiazek, I.
    Zastrow, K-D.
    Coffey, I. H.
    Jakubowska, K.
    Lawson, K. D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):