Importance of Calibration Method in Central Blood Pressure for Cardiac Structural Abnormalities

被引:44
|
作者
Negishi, Kazuaki [1 ]
Yang, Hong [1 ]
Wang, Ying [1 ]
Nolan, Mark T. [1 ]
Negishi, Tomoko [1 ]
Pathan, Faraz [1 ]
Marwick, Thomas H. [1 ]
Sharman, James E. [1 ]
机构
[1] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
关键词
blood pressure determinations; blood vessels; cardiovascular diagnostic technique; heart function tests; hypertension; pulse wave analysis; CENTRAL AORTIC PRESSURE; ALL-CAUSE MORTALITY; ARTERIAL-PRESSURE; TASK-FORCE; MANAGEMENT; ASSOCIATION; VALIDATION;
D O I
10.1093/ajh/hpw039
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Central blood pressure (CBP) independently predicts cardiovascular risk, but calibration methods may affect accuracy of central systolic blood pressure (CSBP). Standard central systolic blood pressure (Stan-CSBP) from peripheral waveforms is usually derived with calibration using brachial SBP and diastolic BP (DBP). However, calibration using oscillometric mean arterial pressure (MAP) and DBP (MAP-CSBP) is purported to provide more accurate representation of true invasive CSBP. This study sought to determine which derived CSBP could more accurately discriminate cardiac structural abnormalities. A total of 349 community-based patients with risk factors (71 +/- 5years, 161 males) had CSBP measured by brachial oscillometry (Mobil-O-Graph, IEM GmbH, Stolberg, Germany) using 2 calibration methods: MAP-CSBP and Stan-CSBP. Left ventricular hypertrophy (LVH) and left atrial dilatation (LAD) were measured based on standard guidelines. MAP-CSBP was higher than Stan-CSBP (149 +/- 20 vs. 128 +/- 15mm Hg, P < 0.0001). Although they were modestly correlated (rho = 0.74, P < 0.001), the Bland-Altman plot demonstrated a large bias (21mm Hg) and limits of agreement (24mm Hg). In receiver operating characteristic (ROC) curve analyses, MAP-CSBP significantly better discriminated LVH compared with Stan-CSBP (area under the curve (AUC) 0.66 vs. 0.59, P = 0.0063) and brachial SBP (0.62, P = 0.027). Continuous net reclassification improvement (NRI) (P < 0.001) and integrated discrimination improvement (IDI) (P < 0.001) corroborated superior discrimination of LVH by MAP-CSBP. Similarly, MAP-CSBP better distinguished LAD than Stan-CSBP (AUC 0.63 vs. 0.56, P = 0.005) and conventional brachial SBP (0.58, P = 0.006), whereas Stan-CSBP provided no better discrimination than conventional brachial BP (P = 0.09). CSBP is calibration dependent and when oscillometric MAP and DBP are used, the derived CSBP is a better discriminator for cardiac structural abnormalities.
引用
收藏
页码:1070 / 1076
页数:7
相关论文
共 50 条
  • [41] CENTRAL VENOUS PRESSURE IN RELATION TO CARDIAC COMPETENCE BLOOD VOLUME AND EXERCISE
    LANDIS, EM
    BROWN, E
    FAUTEUX, M
    WISE, C
    JOURNAL OF CLINICAL INVESTIGATION, 1946, 25 (02): : 237 - 255
  • [42] The importance of blood resistivity in the measurement of cardiac output by the thoracic impedance method
    Hill, D.W.
    Thompson, F.D.
    1975, 13 (02): : 187 - 191
  • [43] 7.3: Microcirculation Abnormalities as Related to Arterial Stiffness and Central Blood Pressure in Hypertensive Patients
    M. L. Muiesan
    D. Rizzoni
    M. Salvetti
    A. Paini
    C. Agabiti Rosei
    C. Aggiusti
    F. Bertacchini
    F. Beschi
    A. Agazzi
    E. Porteri
    C. De Ciuceis
    E. Agabiti Rosei
    Artery Research, 2011, 5 (4) : 147 - 147
  • [44] Exenatide Attenuation of Cardiac Rhythm Abnormalities and Blood Pressure Changes Induced by Doxorubicin in Rats
    Younis, Nancy Safwat
    Al Ahmed, Anas
    Al Mulhim, Noufah
    AlGarni, Azizah Ali
    Madu, Emeka Promise
    INTERNATIONAL JOURNAL OF PHARMACOLOGY, 2017, 13 (08) : 1098 - 1102
  • [45] Obesity related changes in cardiac structure and function: role of blood pressure and metabolic abnormalities
    Di Chiara, Tiziana
    Tuttolomondo, Antonino
    Parrinello, Gaspare
    Colomba, Daniela
    Pinto, Antonio
    Scaglione, Rosario
    ACTA CARDIOLOGICA, 2020, 75 (05) : 413 - 420
  • [46] P7.16 Validation of an Oscillometric Brachial Cuff Method to Derive Central Blood Pressure Using Different Calibration Modes
    Martin Schultz
    Ahmad Qasem
    Xiaoqing Peng
    Dean Picone
    J. Andrew Black
    Nathan Dwyer
    Phillip Roberts-Thomson
    James Sharman
    Artery Research, 2015, 12 (1) : 33 - 33
  • [47] THE EFFECT OF CALIBRATION ERROR ON THE TRANSFER-FUNCTION-DERIVED CENTRAL AORTIC BLOOD PRESSURE
    Cheng, Hao-min
    Shih, Yuan-Ta
    Wang, Kang-Ling
    Sun, Yi-Jung
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Chen, Lung-Ching
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Lee, Wen-Shin
    Yu, Wen-Chung
    Hu, Wei-Chih
    Chen, Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [48] Central blood pressure monitoring method oriented to wearable devices
    Fierro G.
    Silveira F.
    Armentano R.
    Health and Technology, 2016, 6 (3) : 197 - 204
  • [49] Determination of central blood pressure by a noninvasive method (brachial blood pressure and QKD interval): a noninvasive validation
    Cremer, Antoine
    Codjo, Leopold
    Butlin, Mark
    Papaioannou, Georgios
    Yeim, Sunthareth
    Jan, Emilie
    Kiat, Hosen
    Avolio, Alberto
    Gosse, Philippe
    JOURNAL OF HYPERTENSION, 2013, 31 (09) : 1847 - 1852
  • [50] Blunted blood pressure response to central sympathoinhibition in normotensive blacks - Increased importance of nonsympathetic factors in blood pressure maintenance in blacks
    Lang, CC
    Stein, CM
    He, HB
    Belas, FJ
    Blair, IA
    Wood, M
    Wood, AJJ
    HYPERTENSION, 1997, 30 (02) : 157 - 162