Amplitude-Modulated Cavity-Enhanced Absorption Spectroscopy with Phase-Sensitive Detection: A New Approach Applied to the Fast and Sensitive Detection of NO2

被引:7
|
作者
Zhou, Jiacheng [1 ,2 ]
Zhao, Weixiong [1 ]
Zhang, Yang [1 ]
Fang, Bo [1 ]
Cheng, Feihu [1 ]
Xu, Xuezhe [1 ]
Ni, Shichuan [1 ,2 ]
Zhang, Weijun [1 ,2 ]
Ye, Chunxiang [3 ]
Chen, Weidong [4 ]
Venables, Dean S. [5 ,6 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, HFIPS, Lab Atmospher Physicochem, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Peking Univ, Coll Environm Sci & Engn, Beijing 100871, Peoples R China
[4] Univ Littoral Cote dOpale, Lab Physicochim Atmosph, F-59140 Dunkerque, France
[5] Univ Coll Cork, Sch Chem, Cork T23 XE10, Ireland
[6] Univ Coll Cork, Environm Res Inst, Cork T23 XE10, Ireland
基金
中国国家自然科学基金;
关键词
RING-DOWN SPECTROSCOPY; SPECTROMETER TD-CRDS; CHEMICAL AMPLIFICATION; DIODE-LASER; REAL-TIME; NITROGEN-DIOXIDE; PEROXY-RADICALS; MIXING RATIOS; AMBIENT NO2; IN-SITU;
D O I
10.1021/acs.analchem.1c05484
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and sensitive measurements of NO2 play an extremely important role in atmospheric studies. Increasingly, studies require NO2 measurements with parts per trillion by volume (pptv-level) detection limits. Other desirable instrument attributes include ease of use, long-term stability, and low maintenance. In this work, we report the development of an amplitude-modulated multimode-diodelaser-based cavity-enhanced absorption spectroscopy (AM-CEAS) system operating at 406 nm that uses phase-sensitive detection for extremely sensitive NO2 detection. The laser was TTL-modulated at 35 kHz. The mirror reflectivity was determined to be 99.985% based on the ring-down time measurement. The cavity base length was 47.5 cm, giving an effective absorption pathlength of similar to 3.26 km. AM-CEAS achieved a 1s detection precision of 35 pptv in a 1 s data acquisition time (4.98 x 10(-10) cm(-1)), over 4 times lower than that attained using a ringdown approach and the same optical system. The AM-CEAS precision improved to 8 pptv over a data acquisition time of 30 s (1.14 x 10(-10) cm(-1)). The AM-CEAS method with the multimode diode laser integrates the advantages of high light injection efficiency like on-axis alignment cavity ring-down spectroscopy, low cavity-mode noise like off-axis alignment CEAS, and narrow-bandwidth high-sensitivity weak signal detection of modulation spectroscopy, providing a powerful, straightforward, and general method for ultrasensitive absorption and extinction measurements.
引用
收藏
页码:3368 / 3375
页数:8
相关论文
共 40 条
  • [31] Improvement of detection system for a fast-scanning and phase-sensitive laser probe for surface acoustic wave devices in 2 GHz range
    Kashiwa, Keisuke
    Omori, Tatsuya
    Hashimoto, Ken-Ya
    Yamaguchi, Masatsune
    Japanese Journal of Applied Physics, 2008, 47 (5 PART 2): : 4108 - 4110
  • [32] VACUUM ULTRAVIOLET PHOTOELECTRON-SPECTROSCOPY OF TRANSIENT SPECIES .2. USE OF PHASE-SENSITIVE DETECTION FOR INVESTIGATING ELECTRONIC STATES OF O +/2
    JONATHAN, N
    MORRIS, A
    OKUDA, M
    ROSS, KJ
    SMITH, DJ
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1974, 70 : 1810 - 1817
  • [33] Sensitive trace gas detection with cavity enhanced absorption spectroscopy using a continuous wave external-cavity quantum cascade laser (vol 103, 131114, 2013)
    van Helden, J. H.
    Lang, N.
    Macherius, U.
    Zimmermann, H.
    Roepcke, J.
    APPLIED PHYSICS LETTERS, 2014, 104 (09)
  • [34] Improvement of Detection System for a Fast-Scanning and Phase-Sensitive Laser Probe for Surface Acoustic Wave Devices in 2GHz Range
    Kashiwa, Keisuke
    Omori, Tatsuya
    Hashimoto, Ken-ya
    Yamaguchi, Masatsune
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (05) : 4108 - 4110
  • [35] Dual-feedback mid-infrared cavity-enhanced absorption spectroscopy for H2CO detection using a radio-frequency electrically-modulated interband cascade laser
    He, Qixin
    Zheng, Chuantao
    Lou, Minhan
    Ye, Weilin
    Wang, Yiding
    Tittel, Frank K.
    OPTICS EXPRESS, 2018, 26 (12): : 15436 - 15444
  • [36] Detection of shock-heated hydrogen peroxide (H2O2) by off-axis cavity-enhanced absorption spectroscopy (OA-CEAS)
    Awad B. S. Alquaity
    Utsav KC
    Alber Popov
    Aamir Farooq
    Applied Physics B, 2017, 123
  • [37] Detection of shock-heated hydrogen peroxide - (H2O2) by off-axis cavity-enhanced absorption spectroscopy (OA-CEAS)
    Alquaity, Awad B. S.
    Utsav, K. C.
    Popov, Alber
    Farooq, Aamir
    APPLIED PHYSICS B-LASERS AND OPTICS, 2017, 123 (12):
  • [38] In situ infrared spectroscopy of catalytic solid-liquid interfaces using phase-sensitive detection:: Enantioselective hydrogenation of a pyrone over Pd/TiO2
    Bürgi, T
    Baiker, A
    JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (41): : 10649 - 10658
  • [39] Mid-infrared cavity-enhanced absorption sensor for ppb-level N2O detection using an injection-current-modulated quantum cascade laser
    Yang, Min
    Wang, Zhen
    Nie, Qinxue
    Ni, Kai
    Ren, Wei
    OPTICS EXPRESS, 2021, 29 (25): : 41634 - 41642
  • [40] Simultaneous detection of C2H6, CH4, and δ13C-CH4 using optical feedback cavity-enhanced absorption spectroscopy in the mid-infrared region: towards application for dissolved gas measurements
    Lechevallier, Loic
    Grilli, Roberto
    Kerstel, Erik
    Romanini, Daniele
    Chappellaz, Jerome
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (06) : 3101 - 3109