Amplitude-Modulated Cavity-Enhanced Absorption Spectroscopy with Phase-Sensitive Detection: A New Approach Applied to the Fast and Sensitive Detection of NO2

被引:7
|
作者
Zhou, Jiacheng [1 ,2 ]
Zhao, Weixiong [1 ]
Zhang, Yang [1 ]
Fang, Bo [1 ]
Cheng, Feihu [1 ]
Xu, Xuezhe [1 ]
Ni, Shichuan [1 ,2 ]
Zhang, Weijun [1 ,2 ]
Ye, Chunxiang [3 ]
Chen, Weidong [4 ]
Venables, Dean S. [5 ,6 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, HFIPS, Lab Atmospher Physicochem, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Peking Univ, Coll Environm Sci & Engn, Beijing 100871, Peoples R China
[4] Univ Littoral Cote dOpale, Lab Physicochim Atmosph, F-59140 Dunkerque, France
[5] Univ Coll Cork, Sch Chem, Cork T23 XE10, Ireland
[6] Univ Coll Cork, Environm Res Inst, Cork T23 XE10, Ireland
基金
中国国家自然科学基金;
关键词
RING-DOWN SPECTROSCOPY; SPECTROMETER TD-CRDS; CHEMICAL AMPLIFICATION; DIODE-LASER; REAL-TIME; NITROGEN-DIOXIDE; PEROXY-RADICALS; MIXING RATIOS; AMBIENT NO2; IN-SITU;
D O I
10.1021/acs.analchem.1c05484
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and sensitive measurements of NO2 play an extremely important role in atmospheric studies. Increasingly, studies require NO2 measurements with parts per trillion by volume (pptv-level) detection limits. Other desirable instrument attributes include ease of use, long-term stability, and low maintenance. In this work, we report the development of an amplitude-modulated multimode-diodelaser-based cavity-enhanced absorption spectroscopy (AM-CEAS) system operating at 406 nm that uses phase-sensitive detection for extremely sensitive NO2 detection. The laser was TTL-modulated at 35 kHz. The mirror reflectivity was determined to be 99.985% based on the ring-down time measurement. The cavity base length was 47.5 cm, giving an effective absorption pathlength of similar to 3.26 km. AM-CEAS achieved a 1s detection precision of 35 pptv in a 1 s data acquisition time (4.98 x 10(-10) cm(-1)), over 4 times lower than that attained using a ringdown approach and the same optical system. The AM-CEAS precision improved to 8 pptv over a data acquisition time of 30 s (1.14 x 10(-10) cm(-1)). The AM-CEAS method with the multimode diode laser integrates the advantages of high light injection efficiency like on-axis alignment cavity ring-down spectroscopy, low cavity-mode noise like off-axis alignment CEAS, and narrow-bandwidth high-sensitivity weak signal detection of modulation spectroscopy, providing a powerful, straightforward, and general method for ultrasensitive absorption and extinction measurements.
引用
收藏
页码:3368 / 3375
页数:8
相关论文
共 40 条
  • [21] Development of a new Long Path Absorption Photometer (LOPAP) instrument for the sensitive detection of NO2 in the atmosphere
    Villena, G.
    Bejan, I.
    Kurtenbach, R.
    Wiesen, P.
    Kleffmann, J.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2011, 4 (08) : 1663 - 1676
  • [22] Noise-immune cavity-enhanced optical frequency comb spectroscopy: a sensitive technique for high-resolution broadband molecular detection
    Amir Khodabakhsh
    Alexandra C. Johansson
    Aleksandra Foltynowicz
    Applied Physics B, 2015, 119 : 87 - 96
  • [23] A Demonstration of Broadband Cavity-Enhanced Absorption Spectroscopy at Deep-Ultraviolet Wavelengths: Application to Sensitive Real-Time Detection of the Aromatic Pollutants Benzene, Toluene, and Xylene
    Wang, Meng
    Varma, Ravi
    Venables, Dean S.
    Zhou, Wu
    Chen, Jun
    ANALYTICAL CHEMISTRY, 2022, 94 (10) : 4286 - 4293
  • [24] High-resolution HO2 radical detection by optical feedback linear cavity-enhanced absorption spectroscopy
    Chen, Yang
    Yang, Nana
    Fang, Bo
    Zhao, Weixiong
    Zhang, Weijun
    Li, Shuangshuang
    Cui, Weihua
    APPLIED PHYSICS B-LASERS AND OPTICS, 2024, 130 (08):
  • [25] Detection of HO2 in an atmospheric pressure plasma jet using optical feedback cavity-enhanced absorption spectroscopy
    Gianella, Michele
    Reuter, Stephan
    Aguila, Ana Lawry
    Ritchie, Grant A. D.
    van Helden, Jean-Pierre H.
    NEW JOURNAL OF PHYSICS, 2016, 18
  • [26] Sensitive trace gas detection with cavity enhanced absorption spectroscopy using a continuous wave external-cavity quantum cascade laser
    van Helden, J. H.
    Lang, N.
    Macherius, U.
    Zimmermann, H.
    Roepcke, J.
    APPLIED PHYSICS LETTERS, 2013, 103 (13)
  • [27] A new method of phase sensitive detection in modulation spectroscopy applied to temperature induced folding and unfolding of RNase A
    Baurecht, D
    Porth, I
    Fringeli, UP
    VIBRATIONAL SPECTROSCOPY, 2002, 30 (01) : 85 - 92
  • [28] Simultaneous measurement of gas absorption and path length based on the dual-sideband heterodyne phase-sensitive detection of dispersion spectroscopy
    Zou, Mingli
    Sun, Liqun
    Li, Shaomin
    OPTICS EXPRESS, 2021, 29 (08) : 11683 - 11692
  • [29] Incoherent broad-band cavity enhanced absorption spectroscopy for sensitive and rapid molecular iodine detection in the presence of aerosols and water vapour
    Bahrini, Chiheb
    Gregoire, Anne-Cecile
    Obada, Dorel
    Mun, Christian
    Fittschen, Christa
    OPTICS AND LASER TECHNOLOGY, 2018, 108 : 466 - 479
  • [30] A NEW METHOD FOR RESOLUTION OF 2-COMPONENT AND 3-COMPONENT MIXTURES OF FLUOROPHORES BY PHASE-SENSITIVE DETECTION OF FLUORESCENCE
    KEATINGNAKAMOTO, S
    CHEREK, H
    LAKOWICZ, JR
    ANALYTICAL BIOCHEMISTRY, 1985, 148 (02) : 349 - 356