Amplitude-Modulated Cavity-Enhanced Absorption Spectroscopy with Phase-Sensitive Detection: A New Approach Applied to the Fast and Sensitive Detection of NO2

被引:7
|
作者
Zhou, Jiacheng [1 ,2 ]
Zhao, Weixiong [1 ]
Zhang, Yang [1 ]
Fang, Bo [1 ]
Cheng, Feihu [1 ]
Xu, Xuezhe [1 ]
Ni, Shichuan [1 ,2 ]
Zhang, Weijun [1 ,2 ]
Ye, Chunxiang [3 ]
Chen, Weidong [4 ]
Venables, Dean S. [5 ,6 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, HFIPS, Lab Atmospher Physicochem, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Peking Univ, Coll Environm Sci & Engn, Beijing 100871, Peoples R China
[4] Univ Littoral Cote dOpale, Lab Physicochim Atmosph, F-59140 Dunkerque, France
[5] Univ Coll Cork, Sch Chem, Cork T23 XE10, Ireland
[6] Univ Coll Cork, Environm Res Inst, Cork T23 XE10, Ireland
基金
中国国家自然科学基金;
关键词
RING-DOWN SPECTROSCOPY; SPECTROMETER TD-CRDS; CHEMICAL AMPLIFICATION; DIODE-LASER; REAL-TIME; NITROGEN-DIOXIDE; PEROXY-RADICALS; MIXING RATIOS; AMBIENT NO2; IN-SITU;
D O I
10.1021/acs.analchem.1c05484
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and sensitive measurements of NO2 play an extremely important role in atmospheric studies. Increasingly, studies require NO2 measurements with parts per trillion by volume (pptv-level) detection limits. Other desirable instrument attributes include ease of use, long-term stability, and low maintenance. In this work, we report the development of an amplitude-modulated multimode-diodelaser-based cavity-enhanced absorption spectroscopy (AM-CEAS) system operating at 406 nm that uses phase-sensitive detection for extremely sensitive NO2 detection. The laser was TTL-modulated at 35 kHz. The mirror reflectivity was determined to be 99.985% based on the ring-down time measurement. The cavity base length was 47.5 cm, giving an effective absorption pathlength of similar to 3.26 km. AM-CEAS achieved a 1s detection precision of 35 pptv in a 1 s data acquisition time (4.98 x 10(-10) cm(-1)), over 4 times lower than that attained using a ringdown approach and the same optical system. The AM-CEAS precision improved to 8 pptv over a data acquisition time of 30 s (1.14 x 10(-10) cm(-1)). The AM-CEAS method with the multimode diode laser integrates the advantages of high light injection efficiency like on-axis alignment cavity ring-down spectroscopy, low cavity-mode noise like off-axis alignment CEAS, and narrow-bandwidth high-sensitivity weak signal detection of modulation spectroscopy, providing a powerful, straightforward, and general method for ultrasensitive absorption and extinction measurements.
引用
收藏
页码:3368 / 3375
页数:8
相关论文
共 40 条
  • [1] Sensitive detection of NO2 with cavity enhanced spectroscopy
    Wojtas, Jacek
    Czyzewski, Adam
    Stacewicz, Tadeusz
    Bielecki, Zbigniew
    OPTICA APPLICATA, 2006, 36 (04) : 461 - 467
  • [2] Sensitive detection of NO2 with cavity enhanced spectroscopy
    Military University of Technology, Kaliskiego 2, 00-908 Warsaw, Poland
    不详
    不详
    Opt Appl, 2006, 4 (461-467):
  • [3] High-resolution cavity enhanced absorption spectroscopy using phase-sensitive detection
    Chan, MC
    Yeung, SH
    CHEMICAL PHYSICS LETTERS, 2003, 373 (1-2) : 100 - 108
  • [4] Supercontinuum high-speed cavity-enhanced absorption spectroscopy for sensitive multispecies detection
    Werblinski, Thomas
    Laemmlein, Bastian
    Huber, Franz J. T.
    Zigan, Lars
    Will, Stefan
    OPTICS LETTERS, 2016, 41 (10) : 2322 - 2325
  • [5] SENSITIVE AMPLITUDE-MODULATED AND PHASE-MODULATED ABSORPTION-SPECTROSCOPY WITH A CONTINUOUSLY TUNABLE DIODE-LASER
    GROSSKLOSS, R
    KERSTEN, P
    DEMTRODER, W
    APPLIED PHYSICS B-LASERS AND OPTICS, 1994, 58 (02): : 137 - 142
  • [6] Sensitive Detection of Ambient Formaldehyde by Incoherent Broadband Cavity Enhanced Absorption Spectroscopy
    Liu, Jingwei
    Li, Xin
    Yang, Yiming
    Wang, Haichao
    Kuang, Cailing
    Zhu, Yuan
    Chen, Mindong
    Hu, Jianlin
    Zeng, Limin
    Zhang, Yuanhang
    ANALYTICAL CHEMISTRY, 2020, 92 (03) : 2697 - 2705
  • [7] Cavity-enhanced dual-comb spectroscopy for sensitive OH detection in a laminar premixed flame
    Sun, Haojia
    Wen, Daxin
    Cheong, Kin-Pang
    Ma, Liuhao
    Ni, Kai
    Ren, Wei
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [8] Sub-ppb NO2 detection by optical feedback cavity-enhanced absorption spectroscopy with a blue diode laser
    Courtillot, I.
    Morville, J.
    Motto-Ros, V.
    Romanini, D.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 407 - 412
  • [9] Sub-ppb NO2 detection by optical feedback cavity-enhanced absorption spectroscopy with a blue diode laser
    I. Courtillot
    J. Morville
    V. Motto-Ros
    D. Romanini
    Applied Physics B, 2006, 85 : 407 - 412
  • [10] Sensitive CH4 detection applying quantum cascade laser based optical feedback cavity-enhanced absorption spectroscopy
    Lang, N.
    Macherius, U.
    Wiese, M.
    Zimmermann, H.
    Roepcke, J.
    van Helden, J. H.
    OPTICS EXPRESS, 2016, 24 (06): : A536 - A543