Derivatization enhances analysis of estrogens and their bioactive metabolites in human plasma by liquid chromatography tandem mass spectrometry

被引:36
|
作者
Denver, Nina [1 ,2 ]
Khan, Shazia [1 ]
Stasinopoulos, Ioannis [1 ]
Church, Colin [3 ]
Homer, Natalie Z. M. [1 ]
MacLean, Margaret R. [2 ]
Andrew, Ruth [1 ]
机构
[1] Queens Med Res Inst, Edinburgh Clin Res Facil, Mass Spectrometry Core, 47 Little France Crescent, Edinburgh EH16 4TJ, Midlothian, Scotland
[2] Univ Glasgow, Coll Med Vet & Life Sci, Inst Cardiovasc & Med Sci, Univ Ave, Glasgow G12 8QQ, Lanark, Scotland
[3] Golden Jubilee Natl Hosp, Scottish Pulm Vasc Unit, Agamemnon St, Clydebank G81 4DY, Scotland
基金
英国惠康基金; 英国生物技术与生命科学研究理事会;
关键词
Derivatization; Estrogen; Liquid chromatography tandem mass spectrometry; Estrogen metabolites; Methylpiperazine; LC-MS/MS METHOD; POSTMENOPAUSAL WOMEN; HUMAN SERUM; QUANTIFICATION; ESTRADIOL; ESTRONE; TESTOSTERONE; HYPERTENSION; SENSITIVITY; STEROIDS;
D O I
10.1016/j.aca.2018.12.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Estrogens regulate many diverse biological processes in health and disease. They circulate at a wide range of concentrations in females generating several active metabolites (hydroxy and methoxyestrogens). The metabolites are assumed to be present in much lower levels and are thought to contribute to diseases such as pulmonary arterial hypertension (PAH). Estrogen metabolites are challenging to quantify in plasma and currently available immunoassays are non-specific. Here we have developed and validated a novel assay to simultaneously quantify parent estrogens and their metabolites by mass spectrometry (MS). Estrogens were extracted from human plasma using solid phase extraction and derivatized using 1-(5-fluoro-2, 4-dinitrophenyl)-4-methylpiperazine (PPZ) before quaternization by methylation ("MPPZ"). MPPZ derivatives were separated and quantified by liquid chromatography tandem MS (LC-MS/MS) in positive electrospray ionization mode, using a QTrap 6500 + coupled to a Shimadzu Nexera X2. Separation was achieved using an ACE Excel 2 C18-PFP column (2 mm, 2.1 mm x 150 mm). The limits of quantification (LOQ) were 0.43-2.17 pg on column with a linear range from 2 or 10 - 2000 pg mL(-1). Intra and inter-day precision and accuracy were acceptable (< 20% at LOQ and < 15% above). These derivatives demonstrated minimal degradation upon short-term storage at 15 degrees C (< 20%) and longer term at -20 degrees C (< 20%). Using this approach, estrone (E1) and estradiol (E2) were detected in plasma (0.5 mL) from healthy women and those with PAH but downstream metabolites 16-hydroxy-E1, 16-hydroxy-E2, 2-methoxy-E1 and 4-methoxy-E1 were only detected in plasma from diseased patients. These findings will next be tested robustly in large patient cohorts. This novel LC-MS/MS analysis of estrogens and their bioactive metabolites, using MPPZ derivatization, opens doors for the simultaneous analysis of a panel of estrogens in human plasma, across the endogenous range of concentrations encountered in health and disease. (C) 2019 The Authors. Published by Elsevier B.V.
引用
收藏
页码:84 / 94
页数:11
相关论文
共 50 条
  • [21] Liquid chromatography-tandem mass spectrometry analysis for azaspiracids and their metabolites
    Wu Haiyan
    Guo Mengmeng
    Zhao Chunxia
    Tan Zhijun
    Gu Haifeng
    Zhai Yuxiu
    Lu Lina
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (04) : 401 - 406
  • [22] Determination of phenethyl isothiocyanate in human plasma and urine by ammonia derivatization and liquid chromatography-tandem mass spectrometry
    Ji, Y
    Morris, ME
    ANALYTICAL BIOCHEMISTRY, 2003, 323 (01) : 39 - 47
  • [23] A simple and sensitive assay for the quantitative analysis of paclitaxel and metabolites in human plasma using liquid chromatography/tandem mass spectrometry
    Vainchtein, LD
    Thijssen, B
    Stokvis, E
    Rosing, H
    Schellens, JHM
    Beijnen, JH
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (01) : 139 - 148
  • [24] Simultaneous analysis of flunitrazepam and its major metabolites in human plasma by high performance liquid chromatography tandem mass spectrometry
    Kollroser, M
    Schober, C
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) : 1173 - 1182
  • [25] Simultaneous determination of triazolam and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pan, Ryh-Nan
    Lin, Chang-Ching
    Huang, Pei-Wei
    Hsiong, Cheng-Huei
    Pao, Li-Heng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 58 - 62
  • [26] Simultaneous determination of glimepiride and its metabolites in human plasma by liquid chromatography coupled to a tandem mass spectrometry
    Kyeumhan Noh
    Eunyoung Kim
    Taecheon Jeong
    MinKyun Na
    Moon-Chang Baek
    Kwang-Hyeon Liu
    Pil-Hoon Park
    Beom Soo Shin
    Wonku Kang
    Archives of Pharmacal Research, 2011, 34 : 2073 - 2078
  • [27] Measurement of homocysteine and related metabolites in human plasma and urine by liquid chromatography electrospray tandem mass spectrometry
    Rafii, Mahroukh
    Elango, Rajavel
    House, James D.
    Courtney-Martin, Glenda
    Darling, Pauline
    Fisher, Lawrence
    Pencharz, Paul B.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (28): : 3282 - 3291
  • [28] Simultaneous Determination of Glimepiride and its Metabolites in Human Plasma by Liquid Chromatography Coupled to a Tandem Mass Spectrometry
    Noh, Kyeumhan
    Kim, Eunyoung
    Jeong, Taecheon
    Na, MinKyun
    Baek, Moon-Chang
    Liu, Kwang-Hyeon
    Park, Pil-Hoon
    Shin, Beom Soo
    Kang, Wonku
    ARCHIVES OF PHARMACAL RESEARCH, 2011, 34 (12) : 2073 - 2078
  • [29] Simultaneous determination of ivabradine and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    François-Bouchard, M
    Simonin, G
    Bossant, MJ
    Boursier-Neyret, C
    JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02): : 261 - 269
  • [30] Determination of tocopherols and their metabolites by liquid-chromatography coupled with tandem mass spectrometry in human plasma and serum
    Giusepponi, Danilo
    Torquato, Pierangelo
    Bartolini, Desiree
    Piroddi, Marta
    Birringer, Marc
    Lorkowski, Stefan
    Libetta, Carmelo
    Cruciani, Gabriele
    Moretti, Simone
    Saluti, Giorgio
    Galli, Francesco
    Galarini, Roberta
    TALANTA, 2017, 170 : 552 - 561