Discussion on electromagnetic environment of 1000 kV AC overhead transmission lines in China

被引:0
|
作者
Huang, Daochun [1 ]
Ruan, Jiangjun [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hubei, Peoples R China
关键词
altitude above sea level; alternating current (AC); audible noise (AN); control criteria; corona loss (CL); corridor width (CW); electromagnetic environment; electric field intensity (EFI); radio interference (RI); successive images method; surface voltage gradient; subconductor; transmission tines; ultra high voltage (UHV);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Typical proposed 1000 kV single circuit of cup-shaped and compact tower, double-circuit on the same tower AC transmission lines electromagnetic environment problems were analyzed in this paper. Successive images method was applied to calculate conductor surface voltage gradient and power frequency electric field intensity (EFI) at the level of 1 m above ground surface. Corona loss (CL), radio interference (RI) and audible noise (AN) were calculated and the values of typical altitude above sea level were given and discussed. Calculation and discussion results show that three typical tower lines can satisfy electromagnetic environment control criteria by selecting suitable tine parameters. Although there is no measured data in this paper, this can be a reference to the former research work of China UHV AC transmission line design. More suitable CL, RI, AN predicting methods and control criteria in China are needed to be discussed and determined by considering the future demonstration line operating experience and live line measured data, as well as the testing results of UHV AC test base station.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [31] Analysis of Corona on Hybrid DC and AC Overhead Transmission Lines
    El-Deen, Seham Kamal
    Abdel-Salam, Mazen
    El-Mohandes, Mohamed Th.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (10) : 2926 - 2941
  • [32] ELECTROMAGNETIC IMPACT OF TRANSMISSION LINES ON THE ENVIRONMENT
    Ristovski, Leko
    Delipetrov, Todor
    Blazev, Krsto
    Serafimovski, Toni
    GEOCONFERENCE ON SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, SGEM 2013, VOL II, 2013, : 749 - 755
  • [34] Development of Exposed Environment of Overhead Transmission Lines on Mice
    Geng, Duyan
    Xu, Guizhi
    Yu, Hongli
    Li, Cuihuan
    Yang, Qingxin
    Yan, Weili
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 166 - 169
  • [35] Study on lightning performance of 1000 kV AC transmission project
    Wuhan High Voltage Research Institute of SGCC, Wuhan 430074, China
    Gaodianya Jishu, 2006, 12 (40-44):
  • [36] On Nonuniform Transient Electromagnetic Field Coupling to Overhead Transmission Lines
    Guo, Jun
    Xie, Yan-Zhao
    Rachidi, Farhad
    Li, Ke-Jie
    Wang, Shao-Fei
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2018, 66 (06) : 3087 - 3096
  • [37] Research on Helicopter Live-Line Work by Platform Method on 1000 kV UHV AC Transmission Lines
    Liao, Caibo
    Ruan, Jiangjun
    Du, Zhiye
    Liu, Chao
    Wen, Wu
    Zhou, Taotao
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (03)
  • [38] Simulation of electromagnetic induction on DC transmission lines from parallel AC transmission lines
    Lu, Tiebing
    Zhao, Songtao
    Cui, Xiang
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 114 - +
  • [39] Weather dependency of corona losses on 330 kV overhead transmission lines
    Gupta, Pradeep Kumar
    Tuttelberg, Kaur
    Kilter, Jako
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [40] Loadability of 400 kV Four-Bundled Overhead Transmission Lines
    Lauria, D.
    Quaia, S.