Development of Exposed Environment of Overhead Transmission Lines on Mice

被引:0
|
作者
Geng, Duyan [1 ]
Xu, Guizhi [1 ]
Yu, Hongli [1 ]
Li, Cuihuan [1 ]
Yang, Qingxin [1 ]
Yan, Weili [1 ]
机构
[1] Hebei Univ Technol, Key Lab Electromagnet Field & Elect Apparat Relia, Tianjin 300130, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to study the responses that occur in mice chronically exposed to power frequency electromagnetic fields of transmission lines, an exposed environment was constructed in laboratory. Charge simulation method and Biot-Savart law have respectively been adopted to compute the three-dimensional electric and magnetic fields of the exposed environment. Both methods are programmed using the MATLAB software. Simulations indicate that the maximum intensity of electric field, found at the level of 4 centimeters above ground (the height of white mice), can reach up to 0.85 kilometer voltage per meter (kV/m) at ground level, and the magnetic flux density can amount to 58 milli-Gauss (mG). Compared with typical overhead transmission lines, the paper concluded that the exposed condition for mice exposed to has been approached effectively and closely.
引用
收藏
页码:166 / 169
页数:4
相关论文
共 50 条
  • [1] Electromagnetic environment of the overhead transmission lines and electromagnetic pollution
    Wu, Xiong
    Nie, Dingzhen
    Wan, Baoquan
    Zhang, Guangzhou
    Gaodianya Jishu/High Voltage Engineering, 2000, 26 (05): : 24 - 26
  • [2] DEVELOPMENT OF OVERHEAD TRANSMISSION-LINES IN GDR
    BEHREND, G
    DOOR, H
    ENERGIETECHNIK, 1978, 28 (08): : 281 - 284
  • [3] OVERHEAD TRANSMISSION-LINES - REFURBISHMENT AND DEVELOPMENT
    LOUNSBACH, AG
    POWER ENGINEERING JOURNAL, 1994, 8 (04): : 169 - 169
  • [4] Electromagnetic environment of the overhead transmission lines in low and high frequency
    Ungureanu, Marilena
    Rusu, Adrian Constantin
    EEESD '07: PROCEEDINGS OF THE 3RD IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT, ECOSYSTEMS AND SUSTAINABLE DEVELOPMENT, 2007, : 531 - 536
  • [5] DEVELOPMENT OF BOLTLESS SPACERS FOR OVERHEAD TRANSMISSION LINES.
    Kato, J.
    Suzuki, K.
    Katsuoka, N.
    Wauke, T.
    Koyanagi, H.
    Munakata, T.
    Furukawa Denko Jiho/ Furukawa Electric Review, 1981, (71): : 99 - 105
  • [6] PROTECTIO OF OVERHEAD TRANSMISSION LINES
    Chladny, Vladimir
    PROCEEDINGS OF THE 6TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2005, 2005, : 221 - 228
  • [7] Method for the Development of Galloping Distribution Maps for Overhead Transmission Lines
    Yang, Jialun
    Liu, Bin
    Zhao, Bin
    Liu, Yaduo
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) : 5956 - 5958
  • [8] The Development of Cost Assessment Models for Overhead Power Transmission Lines
    Cherepanov, V. V.
    Bakshaeva, N. S.
    Suvorova, I. A.
    ADVANCES IN AUTOMATION, 2020, 641 : 596 - 605
  • [9] Monitoring of overhead transmission lines
    Wilson, M. S.
    Hurlebaus, S.
    STRUCTURAL HEALTH MONITORING 2007: QUANTIFICATION, VALIDATION, AND IMPLEMENTATION, VOLS 1 AND 2, 2007, : 443 - 450
  • [10] Overhead Lines and the Environment.
    Kiessling, Friedrich