Performance of concrete-filled stainless steel tubular (CFSST) columns after exposure to fire

被引:25
|
作者
Tan, Qing-Hua [1 ]
Gardner, Leroy [2 ]
Han, Lin-Hai [3 ]
Song, Tian-Yi [4 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, London, England
[3] Tsinghua Univ, Dept Civil Engn, Beijing, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Concrete-filled stainless steel tubular (CFSST) columns; Post-fire; Finite element analysis (FEA) modelling; Residual strength; Fire safety engineering; COOLING BEHAVIOR; STUB COLUMNS; DESIGN; STRENGTH;
D O I
10.1016/j.tws.2020.106629
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of concrete-filled stainless steel tubular (CFSST) columns subjected to an entire loading-fire history, including four characteristic phases: (i) ambient temperature loading, (ii) heating, (iii) cooling with constant external loads, and (iv) post-fire loading, is investigated in this paper. Sequentially coupled thermal-stress analyses are performed using ABAQUS to establish the temperature field and structural response of CFSST columns. To improve the precision of the finite element analysis (FEA) models, the influence of moisture on the thermal conductivity and specific heat of the concrete in the heating and cooling phases is considered by using subroutines. Existing fire and post-fire test data on CFSST columns are used to validate the FEA modelling. Comparisons between FEA and test results indicate that the accuracy of the model is acceptable; the FEA model is then extended to simulate CFSST columns subjected to the four characteristic phases. The behaviour of the CFSST columns during the four characteristic phases is explained by analysis of the temperature distribution, load versus axial deformation relations, failure modes and internal force redistribution. The excellent post-fire performance of CFSST columns is examined in comparison with traditional concrete-filled carbon steel tubular (CFST) columns with the same total cross-sectional area. The residual strength index is studied with respect to a series of parametric analyses. It is found that the residual strength of CFSST columns is higher than that of CFST columns after the same fire exposure, and that the diameter of the stainless steel tube, slenderness, heating time ratio and load ratio have a significant influence on the residual strength index.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Fire protection thickness of concrete-filled fire-resistant steel tubular columns
    Liu, Yi-Xiang
    Tong, Gen-Shu
    Zhang, Lei
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (12): : 2387 - 2396
  • [42] Finite Element Modeling of Concrete-Filled Steel Tubular Column After Exposure to Fire
    Huo, Jing-si
    Qu, Hui
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 775 - +
  • [43] Near-field blast test on reactive powder concrete-filled steel tubular columns after exposure to fire
    Chen, Wanxiang
    Guo, Zhikun
    Zhang, Tao
    Zou, Huihui
    Gu, Juan
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2016, 7 (02) : 193 - 212
  • [44] Hysteresis behaviours of circular steel reinforced concrete-filled stainless steel tubular columns
    Wang, Zhibin
    Huang, Shutian
    Peng, Guihan
    Lin, Wanfu
    Li, Xinlei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (12): : 97 - 110
  • [45] Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire
    Liu, Wenchao
    Cao, Wanlin
    Zhang, Jianwei
    Wang, Ruwei
    Ren, Lele
    MATERIALS, 2017, 10 (03):
  • [46] ENHANCEMENT OF THE FIRE RESISTANCE OF CONCRETE-FILLED STEEL TUBULAR COLUMNS BY USING HIGH PERFORMANCE STEELS
    Espinos, Ana
    Ibanez, Carmen
    Lapuebla-Ferri, Andres
    Romero, Manuel L.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1470 - 1481
  • [47] Numerical modelling of fibre reinforced concrete-filled stainless steel tubular columns
    Ellobody, Ehab
    THIN-WALLED STRUCTURES, 2013, 63 : 1 - 12
  • [48] Confinement coefficient of concrete-filled square stainless steel tubular stub columns
    Ding, Fa-xing
    Yin, Yi-xiang
    Wang, Liping
    Yu, Yujie
    Luo, Liang
    Yu, Zhi-wu
    STEEL AND COMPOSITE STRUCTURES, 2019, 30 (04): : 337 - 350
  • [49] Tests on sea sand concrete-filled stainless steel tubular stub columns
    Liao, F. Y.
    Hou, C.
    Zhang, W. J.
    Ren, J.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 379 - 384
  • [50] Experimental investigation on concrete-filled stainless steel stiffened tubular stub columns
    Dabaon, M. A.
    El-Boghdadi, M. H.
    Hassanein, M. F.
    ENGINEERING STRUCTURES, 2009, 31 (02) : 300 - 307