Performance of concrete-filled stainless steel tubular (CFSST) columns after exposure to fire

被引:25
|
作者
Tan, Qing-Hua [1 ]
Gardner, Leroy [2 ]
Han, Lin-Hai [3 ]
Song, Tian-Yi [4 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, London, England
[3] Tsinghua Univ, Dept Civil Engn, Beijing, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Concrete-filled stainless steel tubular (CFSST) columns; Post-fire; Finite element analysis (FEA) modelling; Residual strength; Fire safety engineering; COOLING BEHAVIOR; STUB COLUMNS; DESIGN; STRENGTH;
D O I
10.1016/j.tws.2020.106629
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of concrete-filled stainless steel tubular (CFSST) columns subjected to an entire loading-fire history, including four characteristic phases: (i) ambient temperature loading, (ii) heating, (iii) cooling with constant external loads, and (iv) post-fire loading, is investigated in this paper. Sequentially coupled thermal-stress analyses are performed using ABAQUS to establish the temperature field and structural response of CFSST columns. To improve the precision of the finite element analysis (FEA) models, the influence of moisture on the thermal conductivity and specific heat of the concrete in the heating and cooling phases is considered by using subroutines. Existing fire and post-fire test data on CFSST columns are used to validate the FEA modelling. Comparisons between FEA and test results indicate that the accuracy of the model is acceptable; the FEA model is then extended to simulate CFSST columns subjected to the four characteristic phases. The behaviour of the CFSST columns during the four characteristic phases is explained by analysis of the temperature distribution, load versus axial deformation relations, failure modes and internal force redistribution. The excellent post-fire performance of CFSST columns is examined in comparison with traditional concrete-filled carbon steel tubular (CFST) columns with the same total cross-sectional area. The residual strength index is studied with respect to a series of parametric analyses. It is found that the residual strength of CFSST columns is higher than that of CFST columns after the same fire exposure, and that the diameter of the stainless steel tube, slenderness, heating time ratio and load ratio have a significant influence on the residual strength index.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Flexural buckling of circular concrete-filled stainless steel tubular columns
    Hassanein, M. F.
    Shao, Yong-Bo
    Elchalakani, M.
    El Hadidy, A. M.
    MARINE STRUCTURES, 2020, 71
  • [32] Residual Strength of Concrete-Filled Double-Skin Steel Tubular Stub Columns after Exposure to Fire
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 483 - 488
  • [33] Behavior of cross-shaped stiffened concrete-filled steel tubular stub columns after fire exposure
    Wang, Weiwei
    Lyu, Xuetao
    Liu, Xin
    Zheng, Jun
    Gao, Han
    Yu, Yang
    STRUCTURES, 2024, 68
  • [34] Fire resistance of concrete-filled high strength steel tubular columns
    Wang, Ke
    Young, Ben
    THIN-WALLED STRUCTURES, 2013, 71 : 46 - 56
  • [35] Impact and post-impact behaviours of steel-reinforced concrete-filled steel tubular columns after exposure to fire
    Ji, Sun-Hang
    Wang, Wen-Da
    Xian, Wei
    STRUCTURES, 2022, 44 : 680 - 697
  • [36] Cyclic performance of concrete filled steel tubular columns after exposure to fire: Analysis and simplified model
    Han, Lin Hai
    Lin, Xiao Kang
    Yang, You Fu
    ADVANCES IN STRUCTURAL ENGINEERING, 2008, 11 (04) : 455 - 473
  • [37] Behavior of steel beam to concrete-filled steel tubular column connections after exposure to fire
    Han, Lin-Hai
    Huo, Jing-Si
    Wang, Yong-Chang
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (06): : 800 - 814
  • [38] Recycled concrete-filled steel tubular columns
    Yang, You-Fu
    Han, Lin-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1508 - 1515
  • [39] Axial compression performance of rubberized concrete-filled steel tubular stub columns after fire exposure: Experimental investigation and calculation models
    Wang, Yu-Hang
    Zeng, Wenyan
    Ayough, Pouria
    Ren, Wei
    Wang, Weiyong
    Loganathan, Loginy
    Yap, Soon Poh
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 438
  • [40] Structural performance of CFRP-strengthened concrete-filled stainless steel tubular short columns
    Sharif, Alfarabi M.
    Al-Mekhlafi, Galal M.
    Al-Osta, Mohammed A.
    ENGINEERING STRUCTURES, 2019, 183 : 94 - 109