Comparing the mechanical strength of hip spica cast between a conventional and a new method of application

被引:4
|
作者
Wan, Kwong-Lee [1 ]
Shanmugam, Rukmanikanthan [1 ]
Lee, Kun-Yun [2 ]
Saw, Aik [1 ]
机构
[1] Univ Malaya, Dept Orthopaed Surg, NOCERAL, Kuala Lumpur 59100, Federal Territo, Malaysia
[2] Univ Malaya, Dept Social & Prevent Med, Kuala Lumpur, Malaysia
关键词
Cast breakage; Load to failure; Cast stiffness; Developmental dysplasia of the hip (DDH); Plaster of Paris (POP); OSTEOTOMIES; FRACTURES; STABILITY; FIXATION; CHILDREN;
D O I
10.1007/s11832-016-0770-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The current technique of hip spica application is mostly based on a publication by Kumar (J Pediatr Orthop 1(1):97-99, 1981). We modified the technique of hip spica application in order to reduce the rate of breakage across the hip joint and designed this study to compare the strength between hip spica applied according to Kumar's technique and the new technique. We created 12 hip spica casts with 24 hips according to Kumar's technique, and another 12 casts according to a new technique. The two types of spica were tested with a mechanical testing machine (Instron 3365 series) by using compression loading to failure in flexion, extension, abduction and adduction. Data were analysed in SPSS version 20.0. Comparison of means was done with an independent T test for normally distributed data and the Mann-Whitney test for skewed data. The new technique involved the creation of three slabs, instead of 14 slabs as described by Kumar. The loads to failure for hip spica cast applied according to the new technique were higher than those applied according to Kumar's technique, and the differences were statistically significant. The stiffness was also higher in spica casts applied with the new technique; the difference was not statistically significant under extension force. Hip spica applied with the new technique was stronger than that applied according to Kumar's technique based on load to failure testing. The new technique of application would potentially reduce the risk of cast breakage during the management of developmental dysplasia of the hip (DDH) and femur fracture in children.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [31] Relationship between mechanical and metallurgical properties with machinability when drilling high-strength cast irons
    da Silva, Aline Elias
    da Silva, Leonardo Rosa Ribeiro
    dos Reis, Alcione
    Machado, Alisson Rocha
    Guesser, Wilson Luiz
    Ezugwu, Emmanuel Okechukwu
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2020, 106 (7-8): : 3389 - 3407
  • [32] Relationship between mechanical and metallurgical properties with machinability when drilling high-strength cast irons
    Aline Elias da Silva
    Leonardo Rosa Ribeiro da Silva
    Alcione dos Reis
    Álisson Rocha Machado
    Wilson Luiz Guesser
    Emmanuel Okechukwu Ezugwu
    The International Journal of Advanced Manufacturing Technology, 2020, 106 : 3389 - 3407
  • [33] Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength
    Leao Almeida, Gabriel Peixoto
    das Neves Rodrigues, Helena Larissa
    de Freitas, Bruno Wesley
    de Paula Lima, Pedro Olavo
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2017, 47 (12): : 906 - 913
  • [34] Comparing Conventional and New Policy Approaches for Carnivore Conservation: Theoretical Results and Application to Tiger Conservation
    Zabel, Astrid
    Pittel, Karen
    Bostedt, Goran
    Engel, Stefanie
    ENVIRONMENTAL & RESOURCE ECONOMICS, 2011, 48 (02): : 287 - 301
  • [35] Comparing Conventional and New Policy Approaches for Carnivore Conservation: Theoretical Results and Application to Tiger Conservation
    Astrid Zabel
    Karen Pittel
    Göran Bostedt
    Stefanie Engel
    Environmental and Resource Economics, 2011, 48 : 287 - 301
  • [36] New Approaches to Estimation of Correlation Between Strength, Ductility, and Mechanical Stability
    Kotrechko, S. O.
    Meshkov, Yu Ya
    Shiyan, A. V.
    Stetsenko, N. M.
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2011, 33 (09): : 1277 - 1290
  • [37] Observational Application Comparing Problem-Based Learning with the Conventional Teaching Method for Clinical Acupuncture Education
    Kim, Yun Jin
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2019, 2019
  • [38] Comparing a New Power System Preventive Operation Method with a Conventional Industry Practice during Hurricanes
    Sang, Yuanrui
    Sahraei-Ardakani, Mostafa
    Xue, Jiayue
    Ou, Ge
    2019 51ST NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2019,
  • [40] Comparison between a conventional IMRT planning method and a new automated planning method.
    MicheL, M.
    Bertaut, C.
    Castelli, J.
    De Crevoisier, R.
    Lafond, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S767 - S767