Comparing the mechanical strength of hip spica cast between a conventional and a new method of application

被引:4
|
作者
Wan, Kwong-Lee [1 ]
Shanmugam, Rukmanikanthan [1 ]
Lee, Kun-Yun [2 ]
Saw, Aik [1 ]
机构
[1] Univ Malaya, Dept Orthopaed Surg, NOCERAL, Kuala Lumpur 59100, Federal Territo, Malaysia
[2] Univ Malaya, Dept Social & Prevent Med, Kuala Lumpur, Malaysia
关键词
Cast breakage; Load to failure; Cast stiffness; Developmental dysplasia of the hip (DDH); Plaster of Paris (POP); OSTEOTOMIES; FRACTURES; STABILITY; FIXATION; CHILDREN;
D O I
10.1007/s11832-016-0770-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The current technique of hip spica application is mostly based on a publication by Kumar (J Pediatr Orthop 1(1):97-99, 1981). We modified the technique of hip spica application in order to reduce the rate of breakage across the hip joint and designed this study to compare the strength between hip spica applied according to Kumar's technique and the new technique. We created 12 hip spica casts with 24 hips according to Kumar's technique, and another 12 casts according to a new technique. The two types of spica were tested with a mechanical testing machine (Instron 3365 series) by using compression loading to failure in flexion, extension, abduction and adduction. Data were analysed in SPSS version 20.0. Comparison of means was done with an independent T test for normally distributed data and the Mann-Whitney test for skewed data. The new technique involved the creation of three slabs, instead of 14 slabs as described by Kumar. The loads to failure for hip spica cast applied according to the new technique were higher than those applied according to Kumar's technique, and the differences were statistically significant. The stiffness was also higher in spica casts applied with the new technique; the difference was not statistically significant under extension force. Hip spica applied with the new technique was stronger than that applied according to Kumar's technique based on load to failure testing. The new technique of application would potentially reduce the risk of cast breakage during the management of developmental dysplasia of the hip (DDH) and femur fracture in children.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [21] Comparison of fracture strength after thermo-mechanical aging between provisional crowns made with CAD/CAM and conventional method
    Reeponmaha, Tanapon
    Angwaravong, Onauma
    Angwarawong, Thidarat
    JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (04): : 218 - 224
  • [22] SELECTING THE METHOD OF NONDESTRUCTIVE INSPECTION OF THE MECHANICAL PROPERTIES OF HIGH-STRENGTH CAST IRON.
    Burtseva, V.A.
    Pravdin, L.S.
    Shcherbinin, V.E.
    Yakovlev, S.G.
    The Soviet journal of nondestructive testing, 1986, 22 (11): : 772 - 779
  • [23] CONTROL OF THE MECHANICAL-PROPERTIES OF HIGH-STRENGTH CAST-IRON BY THE MAGNETOELASTOACOUSTIC METHOD
    BURTSEVA, VA
    PRAVDIN, LS
    SHCHERBININ, VE
    YAKOVLEV, SG
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1987, 23 (02): : 75 - 81
  • [24] Preliminary results of rigid fixation (locking plate/screw) after triple pelvic osteotomy without a hip spica cast: A modified fixation method in 21 patients
    Kamaci, Saygin
    Kaymakoglu, Mehmet
    Ramazanov, Rafik
    Aksoy, Mehmet Cemalettin
    Yilmaz, Guney
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (02): : 454 - 460
  • [25] An adhesive joint strength evaluation method and its application in mechanical engineering
    Na, Jingxin
    Liu, Yu
    Cai, Liang
    Tao, Shizhen
    Yan, Yakun
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2016, 30 (02) : 131 - 144
  • [26] Comparing a new double reduction method to classic strength reduction method for slope stability analysis
    Bai Bing
    Yuan Wei
    Shi Lu
    Li Jun
    Li Xiao-chun
    ROCK AND SOIL MECHANICS, 2015, 36 (05) : 1275 - 1281
  • [27] A new method for comparing migration abilities of conductor systems based on conventional electroanalytical techniques
    Harsányi, G
    Inzelt, G
    50TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE - 2000 PROCEEDINGS, 2000, : 1666 - 1673
  • [28] Operational Determination of Physical and Mechanical Properties of Cast Samples of High-Strength Iron by Means of a Magnetic-Mechanical Method
    Yu. K. Slyusarev
    A. V. Braga
    I. Yu. Slyusarev
    Metal Science and Heat Treatment, 2017, 59 : 334 - 340
  • [29] SELECTING THE METHOD OF NONDESTRUCTIVE INSPECTION OF THE MECHANICAL-PROPERTIES OF HIGH-STRENGTH CAST-IRON
    BURTSEVA, VA
    PRAVDIN, LS
    SHCHERBININ, VE
    YAKOVLEV, SG
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1986, 22 (11): : 772 - 779
  • [30] Operational Determination of Physical and Mechanical Properties of Cast Samples of High-Strength Iron by Means of a Magnetic-Mechanical Method
    Slyusarev, Yu. K.
    Braga, A. V.
    Slyusarev, I. Yu.
    METAL SCIENCE AND HEAT TREATMENT, 2017, 59 (5-6) : 334 - 340