Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry

被引:7
|
作者
Tolli, H [1 ]
Johansson, KA [1 ]
机构
[1] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Radiat Phys, S-41345 Gothenburg, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 11期
关键词
D O I
10.1088/0031-9155/43/11/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents experimentally determined correction factors for Farmer-type chambers for absorbed dose determination in Co-60 and Ir-192 brachytherapy dosimetry. The correction factors were determined from measurements made in a PMMA phantom and calculation of ratios of measured charges. The ratios were corrected for the different volumes of the ionization chambers, determined in external high-energy electron beams. The correction factors for the central electrode effect and the wall material dependency in Co-60 brachytherapy dosimetry agree with those used in external Co-60 beam dosimetry. In Ir-192 dosimetry, the central aluminium electrode increases the response of an NE2571 chamber compared with that of a chamber with a central graphite electrode. The increase is 1.1 and 2.1% at 1.5 and 5.0 g cm(-2) distance, respectively. Similar values are obtained with an NE2577 chamber. The wall correction factor in Ir-192 dosimetry for a chamber with an A-150 wall has been determined to be 1.018, independent of the measurement distance. For a graphite walled chamber, the correction factor is 0.996 and 1.001 at 1.5 and 5.0 g cm(-2) distance, respectively. The values of the wall correction factors are evaluated by a theory presented. If the chamber is used according to the 'large cavity' principle, the correction factor to account for the replacement of the phantom material by the ionization chamber was determined to be 0.982 for an NE2571 chamber when used with a Delrin cap, and 0.978 for an NE2581 when used with a polystyrene cap. The correction factors for the 'large cavity' principle are valid at both Co-60 and Ir-192 qualities.
引用
收藏
页码:3171 / 3181
页数:11
相关论文
共 50 条
  • [31] NPL's new absorbed dose standard for the calibration of HDR 192Ir brachytherapy sources
    Sander, T.
    Duane, S.
    Lee, N. D.
    Thomas, C. G.
    Owen, P. J.
    Bailey, M.
    Palmans, H.
    METROLOGIA, 2012, 49 (05) : S184 - S188
  • [32] Experimental Determination of Ionization Chamber Correction Factors for In-Phantom Measurements of Reference Air Kerma Rate and Absorbed Water Dose Rate of Brachytherapy 192Ir Source
    Chan, M.
    Lee, V.
    Wong, M.
    Leung, R.
    Law, G.
    Lee, K.
    Cheung, S.
    Tung, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3465 - 3465
  • [33] A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources
    deAlmeida, Carlos Eduardo
    Ochoa, Ricardo
    de Lima, Marilene Coelho
    David, Mariano Gazineu
    Pires, Evandro Jesus
    Peixoto, Jose Guilherme
    Salata, Camila
    Bernal, Mario Antonio
    PLOS ONE, 2014, 9 (12):
  • [34] Monte Carlo-based beam quality and phantom scatter corrections for solid-state detectors in 60Co and 192Ir brachytherapy dosimetry
    Subhalaxmi, Mishra
    Selvam, T. Palani
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 295 - 305
  • [35] Radiobiological and dosimetric comparison of 60Co versus 192Ir high-dose-rate intracavitary-interstitial brachytherapy for cervical cancer
    Wen, Aiping
    Wang, Xianliang
    Wang, Bingjie
    Yan, Chuanjun
    Luo, Jingyue
    Wang, Pei
    Li, Jie
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [36] Radiobiological and dosimetric comparison of 60Co versus 192Ir high-dose-rate intracavitary-interstitial brachytherapy for cervical cancer
    Aiping Wen
    Xianliang Wang
    Bingjie Wang
    Chuanjun Yan
    Jingyue Luo
    Pei Wang
    Jie Li
    Radiation Oncology, 17
  • [37] Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
    Rossi, Giulio
    Gainey, Mark
    Thomann, Benedikt
    Kollefrath, Michael
    Wuerfel, Jan
    Allgaier, Bernd
    Baltas, Dimos
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 272 - 281
  • [38] Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with 192Ir
    Ruiz-Arrebola, Samuel
    Fabregat-Borras, Rosa
    Rodriguez, Eduardo
    Fernandez-Montes, Manuel
    Perez-Macho, Mercedes
    Ferri, Maria
    Garcia, Ana
    Cardenal, Juan
    Pacheco, Maria T.
    Anchuelo, Javier
    Tornero-Lopez, Ana M.
    Prada, Pedro J.
    Guirado, Damian
    MEDICAL PHYSICS, 2020, 47 (05) : 2242 - 2253
  • [39] Erratum to: Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Akbar Sarabiasl
    Navid Ayoobian
    Hossein Poorbaygi
    Iraj Jabbari
    Mohammad Reza Javanshir
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 591 - 591
  • [40] Film dosimetry calibration method for pulsed-dose-rate brachytherapy with an 192Ir source
    Schwob, Nathan
    Orion, Itzhak
    MEDICAL PHYSICS, 2007, 34 (05) : 1678 - 1683