Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry

被引:7
|
作者
Tolli, H [1 ]
Johansson, KA [1 ]
机构
[1] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Radiat Phys, S-41345 Gothenburg, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 11期
关键词
D O I
10.1088/0031-9155/43/11/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents experimentally determined correction factors for Farmer-type chambers for absorbed dose determination in Co-60 and Ir-192 brachytherapy dosimetry. The correction factors were determined from measurements made in a PMMA phantom and calculation of ratios of measured charges. The ratios were corrected for the different volumes of the ionization chambers, determined in external high-energy electron beams. The correction factors for the central electrode effect and the wall material dependency in Co-60 brachytherapy dosimetry agree with those used in external Co-60 beam dosimetry. In Ir-192 dosimetry, the central aluminium electrode increases the response of an NE2571 chamber compared with that of a chamber with a central graphite electrode. The increase is 1.1 and 2.1% at 1.5 and 5.0 g cm(-2) distance, respectively. Similar values are obtained with an NE2577 chamber. The wall correction factor in Ir-192 dosimetry for a chamber with an A-150 wall has been determined to be 1.018, independent of the measurement distance. For a graphite walled chamber, the correction factor is 0.996 and 1.001 at 1.5 and 5.0 g cm(-2) distance, respectively. The values of the wall correction factors are evaluated by a theory presented. If the chamber is used according to the 'large cavity' principle, the correction factor to account for the replacement of the phantom material by the ionization chamber was determined to be 0.982 for an NE2571 chamber when used with a Delrin cap, and 0.978 for an NE2581 when used with a polystyrene cap. The correction factors for the 'large cavity' principle are valid at both Co-60 and Ir-192 qualities.
引用
收藏
页码:3171 / 3181
页数:11
相关论文
共 50 条
  • [21] WP21 BRAPHYQS survey of differences in 192Ir and 60Co brachytherapy RAKR determinations
    Vijande, J.
    Tedgren, A. Carlsson
    Ballester, F.
    Baltas, D.
    Papagiannis, P.
    Rivard, M. J.
    Siebert, F.
    DeWerd, L.
    Perez-Calatayud, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S96 - S97
  • [22] PREPARATION OF VERY HIGH SPECIFIC ACTIVITY 60CO AND 192IR
    CASE, FN
    ACREE, EH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 51 - &
  • [23] Comparison of 192Ir, 169Yb, and 60Co high-dose rate brachytherapy sources for skin cancer treatment
    Safigholi, Habib
    Meigooni, Ali S.
    Song, William Y.
    MEDICAL PHYSICS, 2017, 44 (09) : 4426 - 4436
  • [24] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 413 - 422
  • [25] A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate 192Ir sources
    Guerra, A. S.
    Loreti, S.
    Pimpinella, M.
    Quini, M.
    D'Arienzo, M.
    Astefanoaei, I.
    Caporali, C.
    Bolzan, C.
    Pagliari, M.
    METROLOGIA, 2012, 49 (05) : S179 - S183
  • [26] Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, Vaiva
    Malusek, Alexandr
    Benmakhlouf, Hamza
    Carlsson, Gudrun Alm
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2018, 45 (01) : 429 - 437
  • [27] A novel absorbed dose standard for the calibration of 192Ir sources used in high dose rate brachytherapy
    D'Arienzo, M.
    Guerra, A. S.
    Loreti, S.
    Caporali, C.
    Pimpinella, M.
    Bolzan, C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S146 - S147
  • [28] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [29] A User-Friendly System for Mailed Dosimetric Audits of 192Ir or 60Co HDR Brachytherapy Sources
    Oliver-Canamas, Laura
    Vijande, Javier
    Candela-Juan, Cristian
    Gimeno-Olmos, Jose
    Carmen Pujades-Claumarchirant, Ma
    Rovira-Escutia, Juan J.
    Ballester, Facundo
    Perez-Calatayud, Jose
    CANCERS, 2023, 15 (09)
  • [30] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16