Pilot Study: Comparison of Artifacts of Brackets Using Dual-Energy CT

被引:0
|
作者
Kasslatter, Manuel [1 ]
Glodny, Bernhard [2 ]
Grams, Astrid [2 ]
Crismani, Adriano [1 ]
Schieffer, Lisa [1 ]
机构
[1] Med Univ Innsbruck, Univ Klin Kieferorthopadie, Anichstr 35-G1, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Univ Klin Radiol & Neuroradiol, Innsbruck, Austria
关键词
brackets; dual-energy CT; artifact reduction; monochromatic reconstruction; GOVERNING BODY DONATION; COMPUTED-TOMOGRAPHY; METAL ARTIFACTS; INTRACEREBRAL HEMORRHAGE; IODINATED CONTRAST; MULTIDETECTOR CT; REDUCTION; ANGIOGRAPHY; DIFFERENTIATION; OPTIMIZATION;
D O I
10.1055/a-0966-5829
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Studies on the use of monochrome (MC) imaging after implantation of metallic materials on the extremities or spine have shown that artifacts can be significantly reduced. Due to the high atomic numbers and high density of materials used in orthodontics, maxillofacial surgery and tooth preservation, hardening artifacts present a major problem in computed tomography (CT) imaging of the teeth, and jaw. The limitations of the image quality caused by the visualization of the jaw, and conceivable possibilities for improvement have not been adequately investigated. The aim of this work was to investigate the above artifacts and reduce them by creating monochromes in the jaw area. Dual energy CTs (DECTs) were performed on 10 corpse heads with and without orthodontic appliances. Subsequently, MCs of 80 to 160 kV were produced. The artifacts were assessed qualitatively and quantitatively using established methods. On anatomical structures such as the floor of the mouth and the soft palate, which are not in the same axial plane with high artefact producing objects of high atomic number, an increase of the Hunsfield units (HU) could be observed with increasing kV number of MC. On structures in the same plane with artifact-producing objects, a decrease of the HU could be observed with increasing kV number of MC. This study shows that it is also possible to reduce artifacts in the jaw area using MC. In all investigations no significantly increased artifacts were found in the setting with orthodontic appliances compared to the setting without orthodontic appliances.
引用
收藏
页码:17 / 28
页数:12
相关论文
共 50 条
  • [21] Dual-energy CT of the abdomen
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (01): : 108 - 134
  • [22] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [23] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [24] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [25] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [26] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [27] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [28] A comparison of material decomposition techniques for dual-energy CT colonography
    Nasirudin, Radin A.
    Tachibana, Rie
    Naeppi, Janne J.
    Mei, Kai
    Kopp, Felix K.
    Rummeny, Ernst J.
    Yoshida, Hiroyuki
    Noel, Peter B.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [29] Using Dual-Energy CT for Painful Hip Arthroplasties
    Lutz, Amelie M.
    RADIOLOGY, 2021, 300 (03) : 650 - 651
  • [30] Quantification of Nanoparticle Radiosensitizers Using Dual-Energy CT
    Harris, T.
    Jacobson, M.
    Bennett, S.
    Myronakis, M.
    Ozoemelam, I.
    Hu, Y.
    Sudhyadhom, A.
    Lux, F.
    Tillement, O.
    Berbeco, R.
    MEDICAL PHYSICS, 2022, 49 (06) : E270 - E270