Pilot Study: Comparison of Artifacts of Brackets Using Dual-Energy CT

被引:0
|
作者
Kasslatter, Manuel [1 ]
Glodny, Bernhard [2 ]
Grams, Astrid [2 ]
Crismani, Adriano [1 ]
Schieffer, Lisa [1 ]
机构
[1] Med Univ Innsbruck, Univ Klin Kieferorthopadie, Anichstr 35-G1, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Univ Klin Radiol & Neuroradiol, Innsbruck, Austria
关键词
brackets; dual-energy CT; artifact reduction; monochromatic reconstruction; GOVERNING BODY DONATION; COMPUTED-TOMOGRAPHY; METAL ARTIFACTS; INTRACEREBRAL HEMORRHAGE; IODINATED CONTRAST; MULTIDETECTOR CT; REDUCTION; ANGIOGRAPHY; DIFFERENTIATION; OPTIMIZATION;
D O I
10.1055/a-0966-5829
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Studies on the use of monochrome (MC) imaging after implantation of metallic materials on the extremities or spine have shown that artifacts can be significantly reduced. Due to the high atomic numbers and high density of materials used in orthodontics, maxillofacial surgery and tooth preservation, hardening artifacts present a major problem in computed tomography (CT) imaging of the teeth, and jaw. The limitations of the image quality caused by the visualization of the jaw, and conceivable possibilities for improvement have not been adequately investigated. The aim of this work was to investigate the above artifacts and reduce them by creating monochromes in the jaw area. Dual energy CTs (DECTs) were performed on 10 corpse heads with and without orthodontic appliances. Subsequently, MCs of 80 to 160 kV were produced. The artifacts were assessed qualitatively and quantitatively using established methods. On anatomical structures such as the floor of the mouth and the soft palate, which are not in the same axial plane with high artefact producing objects of high atomic number, an increase of the Hunsfield units (HU) could be observed with increasing kV number of MC. On structures in the same plane with artifact-producing objects, a decrease of the HU could be observed with increasing kV number of MC. This study shows that it is also possible to reduce artifacts in the jaw area using MC. In all investigations no significantly increased artifacts were found in the setting with orthodontic appliances compared to the setting without orthodontic appliances.
引用
收藏
页码:17 / 28
页数:12
相关论文
共 50 条
  • [1] Frequently Encountered Artifacts in Novel Application of Dual-Energy CT to Vascular Imaging: A Pilot Study
    Yokose, Chio
    Eide, Sterling
    Simeone, F. Joseph
    Shojania, Kam
    Nicolaou, Savvas
    Becce, Fabio
    Choi, Hyon K.
    ARTHRITIS & RHEUMATOLOGY, 2019, 71
  • [2] Dual-Energy CT: Too Many Artifacts?
    Fraioli, Francesco
    Ciarlo, Giuseppe
    Anzidei, Michele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) : W783 - W783
  • [3] Recognizing and Minimizing Artifacts at Dual-Energy CT
    Parakh, Anushri
    An, Chansik
    Lennartz, Simon
    Rajiah, Prabhakar
    Yeh, Benjamin M.
    Simeone, Frank J.
    Sahani, Dushyant, V
    Kambadakone, Avinash R.
    RADIOGRAPHICS, 2021, 41 (02) : 509 - 523
  • [4] Fat quantification of the rotator cuff musculature using dual-energy CT-A pilot study
    Baillargeon, Amanda M.
    Baffour, Francis I.
    Yu, Lifeng
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Glazebrook, Katrina N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [5] Pulmonary nodule enhancement in subtraction CT and dual-energy CT: A comparison study
    Grob, Dagmar
    Oostveen, Luuk J.
    Jacobs, Colin
    Scholten, Ernst
    Prokop, Mathias
    Schaefer-Prokop, Cornelia M.
    Sechopoulos, Ioannis
    Brink, Monique
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [6] Evaluation of hepatic steatosis using dual-energy CT with MR comparison
    Sun, Taotao
    Lin, Xiaozhu
    Chen, Kemin
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2014, 19 : 1377 - 1385
  • [7] Recognizing and Minimizing Artifacts at Dual-Energy CT (vol 41, 509, 2021)
    Parakh, Anushri
    An, Chansik
    Lennartz, Simon
    Rajiah, Prabhakar
    Yeh, Benjamin M.
    Simeone, Frank J.
    Sahani, Dushyant V.
    Kambadakone, Avinash R.
    RADIOGRAPHICS, 2021, 41 (03) : E96 - E96
  • [8] Dual-energy CT arthrography: a feasibility study
    Rashpal Sandhu
    Mercan Aslan
    Nancy Obuchowski
    Andrew Primak
    Wadih Karim
    Naveen Subhas
    Skeletal Radiology, 2021, 50 : 693 - 703
  • [9] Dual-energy CT arthrography: a feasibility study
    Sandhu, Rashpal
    Aslan, Mercan
    Obuchowski, Nancy
    Primak, Andrew
    Karim, Wadih
    Subhas, Naveen
    SKELETAL RADIOLOGY, 2021, 50 (04) : 693 - 703
  • [10] Sensitivity of Dual-Energy CT, Ultrasound, and X-Ray for Pseudogout: A Pilot Study
    Tedeschi, Sara K.
    Solomon, Daniel
    Vanni, Kathleen
    Suh, Dong
    Smith, Stacy
    ARTHRITIS & RHEUMATOLOGY, 2019, 71