With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [31] 2 NEW X-RAY SOURCES IN SMC AND HIGH LUMINOSITIES OF MAGELLANIC X-RAY SOURCES
    CLARK, G
    DOXSEY, R
    LI, F
    JERNIGAN, JG
    VANPARADIJS, J
    ASTROPHYSICAL JOURNAL, 1978, 221 (02): : L37 - &
  • [32] X-RAY REFRACTION EFFECT AND DENSITY DETERMINATION OF STEEP-GRADIENT, HIGH-DENSITY PLASMA
    MIYANAGA, N
    KATO, Y
    YAMANAKA, C
    OPTICS COMMUNICATIONS, 1982, 44 (01) : 48 - 52
  • [33] SOFT-X-RAY AND X-RAY ULTRAVIOLET-RADIATION FROM HIGH-DENSITY ALUMINUM PLASMAS
    DUSTON, D
    DAVIS, J
    PHYSICAL REVIEW A, 1981, 23 (05): : 2602 - 2621
  • [34] Novel microfocus x-ray sources for high-pressure crystallography
    Graf, Juergen
    Hasse, Bernd
    Fabbiani, Francesca P. A.
    Probert, Mike. R.
    Goeta, Andres. E.
    Howard, Judith. A. K.
    Michaelsen, Carsten
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C528 - C528
  • [35] Dynamic Hohlraums as x-ray sources in high-energy density science
    Hansen, J. F.
    Glendinning, S. G.
    Heeter, R. F.
    Brockington, S. J. E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (01):
  • [36] A rapid noninvasive characterization of CT x-ray sources
    Randazzo, Matt
    Tambasco, Mauro
    MEDICAL PHYSICS, 2015, 42 (07) : 3960 - 3968
  • [37] X-ray Sources of Nanosecond Pulses Based on Semiconductor Opening Switch for CT
    Komarskiy, A. A.
    Korzhenevskiy, S. R.
    Komarov, N. A.
    6TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE, 2020, 2250
  • [38] 3D printing in X-ray and gamma-ray imaging: A novel method for fabricating high-density imaging apertures
    Miller, Brian W.
    Moore, Jared W.
    Barrett, Harrison H.
    Frye, Teresa
    Adler, Steven
    Sery, Joe
    Furenlid, Lars R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 659 (01): : 262 - 268
  • [39] X-ray transmission effects in a high-density dynamic-dusty plasma environment
    Li, Yao
    Yang, Zhiqiang
    Zhang, Yingjun
    Chen, Mingde
    Xia, Fangyuan
    Yang, Lihong
    Zhang, Furui
    Wu, Yinhua
    Tan, Zhenkun
    Yang, Chen
    Su, Tong
    VACUUM, 2023, 212
  • [40] Evaluation of electrical crosstalk in high-density photodiode arrays for X-ray imaging applications
    Ji, Fan
    Juntunen, Mikko
    Hietanen, Iiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 28 - 30