A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device

被引:11
|
作者
Duan, Yiting [1 ]
Cheng, Haitao [1 ]
Wang, Kai [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect & Informat Engn, Xian 710049, Peoples R China
关键词
Computed tomography; Detectors; Image reconstruction; X-ray imaging; Reconstruction algorithms; Iterative methods; Zinc oxide; Stationary CT scheme; high-density X-ray sources devices; source-detector plate; iterative reconstruction; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CARBON NANOTUBES;
D O I
10.1109/ACCESS.2020.3003308
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [21] Development of highly accurate X-ray mask with high-density patterns
    Shimada, Masaru
    Tsuchizawa, Tai
    Uchiyama, Shingo
    Ohkubo, Takashi
    Itabashi, Seiichi
    Okada, Ikuo
    Ono, Toshiro
    Oda, Masatoshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (12 B): : 7071 - 7075
  • [22] X-RAY AND PARTICLE DIAGNOSTICS OF A HIGH-DENSITY PLASMA BY LASER IMPLOSION
    NAKAI, M
    YAMANAKA, M
    AZECHI, H
    CHEN, YW
    JITSUNO, T
    KATAYAMA, M
    MIMA, M
    MIYANAGA, N
    NAKAISHI, H
    NAKATSUKA, M
    NISHIGUCHI, A
    NORREYS, PA
    SETSUHARA, Y
    TAKAGI, M
    NORIMATSU, T
    YAMANAKA, T
    YAMANAKA, C
    NAKAI, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 3235 - 3240
  • [23] A soft X-ray laser interferogram of a high-density colliding plasma
    Wan, AS
    Barbee, TW
    Cauble, R
    Celliers, P
    Da Silva, LB
    Moreno, JC
    Rambo, PW
    Stone, GF
    Trebes, JE
    Weber, F
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (01) : 120 - 121
  • [24] Numerical simulation of density logging based on X-ray and gamma ray sources
    Zhang F.
    Li Y.
    Xin Y.
    Su B.
    Wu H.
    Zhang Q.
    Liu J.
    2018, University of Petroleum, China (42): : 60 - 66
  • [25] A novel X-ray targeting device
    Butler, M.
    Regan, M. W.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (02) : 179 - 179
  • [26] Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy
    Baissalov, R
    Sandison, GA
    Donnelly, BJ
    Saliken, JC
    McKinnon, JG
    Muldrew, K
    Rewcastle, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : N53 - N59
  • [27] Towards brilliant, compact x-ray sources: A new x-ray photonic device
    Scherer, Brian
    Mandal, Sudeep
    Salisbury, Joshua
    Edic, Peter
    Hopkins, Forrest
    Lee, Susanne M.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) II, 2017, 10187
  • [28] Fabrication of high-aspect-ratio and high-density X-ray transmission grating
    National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
    Guangxue Jingmi Gongcheng, 2009, 1 (72-77):
  • [29] POINT-SOURCE X-RAY BACKLIGHTING FOR HIGH-DENSITY PLASMA DIAGNOSTICS
    MIYANAGA, M
    KATO, Y
    YAMANAKA, C
    APPLIED PHYSICS LETTERS, 1983, 42 (02) : 160 - 162
  • [30] HIGH-DENSITY GLASS SCINTILLATOR FOR REAL-TIME X-RAY INSPECTION
    PLACIOUS, RC
    POLANSKY, D
    BERGER, H
    BUENO, C
    VOSBERG, CL
    BETZ, RA
    ROGERSON, DJ
    MATERIALS EVALUATION, 1991, 49 (11) : 1419 - 1421