A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device

被引:11
|
作者
Duan, Yiting [1 ]
Cheng, Haitao [1 ]
Wang, Kai [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect & Informat Engn, Xian 710049, Peoples R China
关键词
Computed tomography; Detectors; Image reconstruction; X-ray imaging; Reconstruction algorithms; Iterative methods; Zinc oxide; Stationary CT scheme; high-density X-ray sources devices; source-detector plate; iterative reconstruction; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CARBON NANOTUBES;
D O I
10.1109/ACCESS.2020.3003308
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the introduction of cold electron sources such as nanotubes, X-ray sources became small in size so that many sources are installed in array to form stationary CT, which brings benefits of simplicity in mechanism and fast response. However, the nanotube-based X-ray source is still singly packaged and hence density of X-ray sources is limited, which introduces severe sparse-view artifacts and could not be used in practice. With the invention of X-ray sources device based on ZnO nanowires as cold electron emitters, a large amount of X-ray sources is first integrated in a flat panel device. In this study, we design a stationary CT architecture using high-density sources devices, called HD-SCT, and develop corresponding reconstruction algorithm. Specifically, several flat panel detectors and X-ray sources devices are spliced together to form a source-detector plate. Multiple source-detector plates are organized as a polygon that encloses object to complete CT scanning. In HD-SCT, X-ray sources are close to object which can significantly decrease CT device volume. The X-ray beam emitted by each source just cover part of object and the spot sources alternately light to completely scan object. Simultaneously, we propose a reconstruction method for the specific configuration which adopts an iterative algorithm to resolve the reconstruction based on alterative part projections, as well as a novel correction process of projection completion for the shadowed area of placing X-ray source devices. To validate the design of the proposed HD-SCT, we execute a series of simulation experiments, which show that the proposed HD-SCT and corresponding reconstruction method effectively remove the artifacts caused by the embed X-ray source device. The results also disclose that with the increase of density of X-ray sources, the resolution of reconstruction has been dramatically improved, which demonstrates the practical value of introducing high-density X-ray sources device into stationary CT design.
引用
收藏
页码:112910 / 112921
页数:12
相关论文
共 50 条
  • [1] X-ray CT high-density artefact suppression in cryosurgery
    Wei, JK
    Sandison, GA
    Chen, LG
    Liang, Y
    Xu, LX
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (24): : N319 - N326
  • [2] A new CT architecture with stationary x-ray sources
    Cao, Guohua
    Liu, Baodong
    Yu, Hengyong
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [3] X-ray CT high-density artefact suppression in the presence of bones
    Wei, JK
    Chen, LG
    Sandison, GA
    Liang, Y
    Xu, LX
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24): : 5407 - 5418
  • [4] X-RAY STUDY OF HIGH-DENSITY AMORPHOUS WATER
    BOSIO, L
    JOHARI, GP
    TEIXEIRA, J
    PHYSICAL REVIEW LETTERS, 1986, 56 (05) : 460 - 463
  • [5] HIGH-DENSITY PLASMAS FOR RECOMBINATION X-RAY LASERS
    SMITH, RA
    BARROW, V
    EDWARDS, J
    KIEHN, G
    WILLI, O
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1990, 50 (03): : 187 - 192
  • [6] High-density arrays of x-ray microcalorimeters for Constellation-X
    Kilbourne, Caroline A.
    Bandler, Simon R.
    Brown, Ari D.
    Chervenak, James A.
    Figueroa-Feliciano, Enectali
    Finkbeiner, Fred M.
    Iyomoto, Naoko
    Kelley, Richard L.
    Porter, F. Scott
    Saab, Tarek
    Sadleir, John
    White, Jennifer
    SPACE TELESCOPES AND INSTRUMENTATION II: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2006, 6266
  • [7] Note: A novel normalization scheme for laser-based plasma x-ray sources
    Zhang, B. B.
    Sun, S. S.
    Sun, D. R.
    Tao, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09):
  • [9] LOCALIZING DEVICE FOR X-RAY SOURCES
    BENINK, RJ
    RADIOLOGY, 1978, 128 (02) : 508 - 509
  • [10] BIREFRINGENCE AND X-RAY RELAXATION STUDIES OF HIGH-DENSITY POLYETHYLENE
    ANDERSON, D
    CEMBROLA, RJ
    YOUNG, P
    STEIN, RS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (03): : 251 - 251