Patient-specific dose correction for prostate postimplant evaluation with flexible timing of postimplant imaging

被引:0
|
作者
Luo, Wei [1 ]
Cheek, Denise [1 ]
St Clair, William [1 ]
Washington, Brien [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Lexington, KY 40536 USA
关键词
edema; flexible timing; optimal time; patient-specific dose correction; postimplant CT; COMPUTED-TOMOGRAPHY; SEED IMPLANT; INTERSTITIAL BRACHYTHERAPY; AMERICAN-ASSOCIATION; EDEMA; I-125; DOSIMETRY; RECOMMENDATIONS; PD-103; IMPACT;
D O I
10.1002/mp.15968
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The dosimetric effect of edema on prostate implants have long been realized, but large uncertainties still exist in the estimation of dose actually received by the prostate. This study attempted to develop a new method to accurately estimate dose delivered to the prostate accounting for the variation of prostate volume and seed distribution, edema half-lives, and times for postimplant evaluation. Methods and materials A series of prostate seed implants for Cs-131, Pd-103, and I-125 with various prostate volumes were simulated in a water phantom using the TG-43 algorithm on the Varian Eclipse treatment planning system. Dose analysis was performed to derive a quantitative relationship between the prostate peripheral dose and the prostate radius with the variation of prostate volume and seed distribution. Using this relationship to calculate dynamically, the total dose accumulated in the prostate (D-T) accounting for the variation of prostate volume and seed distribution and edema half-lives. Moreover, the total dose can be estimated statically based on the prostate volume that can be determined in a computerized tomography (CT) image taken at a time after implantation. The statically estimated total dose (D-CT) was compared with D-T to determine optimal imaging times as well as dose correction factors for other imaging times. Results An inverse power law was established between the prostate peripheral dose and prostate radius. The value of the power was 1.3 for Cs-131 and I-125, and 1.5 for Pd-103, respectively. D-T was derived dynamically using the inverse power law. Given the edema half-lives, T-E, of 4, 9.3, and 25 days and the volume expansion of 1.1 and 2.0 times of the prostate without edema, the optimal times for postimplant imaging were: 7, 9, and 16 days for T-E = 4 days; 10, 14, and 28 days for T-E = 9.3 days; and 12, 19, 45 days T-E = 25 days, for Cs-131, Pd-103, and I-125, respectively. D-CT calculated using the prostate volume determined on the optimal days agreed with D-T to 0.0%-1.8% and within 0.3% for most cases. For various prostate volumes, edema half-lives, and nonoptimal times, D-CT was able to achieve a 1% accuracy. Conclusion The postimplant dose calculation based on the proposed inverse power law for prostate seed implants with edema has improved the accuracy of postimplant dosimetry with accurate and patient-specific dose corrections accounting for prostate size, edema half-life, and postimplant imaging times. Optimal times for postimplant imaging have been accurately determined, and the high accuracy of postimplant dose calculation can be achieved for both optimal imaging times and nonoptimal imaging times.
引用
收藏
页码:6802 / 6812
页数:11
相关论文
共 50 条
  • [41] Evaluation of Delivered Dose Distributions and Metrics: A New Patient-specific QA Protocol
    Klaers, J.
    Saito, A.
    Goddu, S. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S810 - S811
  • [42] Effects of the Time Interval Between Prostate Brachytherapy and Postimplant Dosimetric Evaluation in Community Practice Analysis of the Pro-Qura Database
    Orio, Peter F., III
    Merick, Gregory S.
    Grimm, Peter
    Blasko, John
    Sylvester, John
    Allen, Zachariah A.
    Butler, Wayne M.
    Chaudhry, Usman-ul-Haq
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (06): : 523 - 531
  • [43] Live implant dosimetry may be an effective replacement for postimplant computed tomography in localized prostate cancer patients receiving low dose rate brachytherapy
    Roshan, Davood
    Joyce, Kieran
    Woulfe, Peter
    Gorakati, Pradeep Reddy
    Stock, Richard
    Sullivan, Francis J.
    BRACHYTHERAPY, 2021, 20 (04) : 873 - 882
  • [44] Minimizing Patient-Specific Tracer Dose in Myocardial Perfusion Imaging Using CZT SPECT
    van Dijk, Joris D.
    Jager, Pieter L.
    Ottervanger, Jan Paul
    Slump, Cornelis H.
    de Boer, Jaep
    Oostdijk, Adrianus H. J.
    van Dalen, Jorn A.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2015, 43 (01) : 36 - 40
  • [45] Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation
    Jia, Xun
    Yan, Hao
    Gu, Xuejun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03): : 577 - 590
  • [46] Use of patient-specific estimates in patient evaluation and rehabilitation
    Stephens, D
    Jaworski, A
    Kerr, P
    Zhao, F
    SCANDINAVIAN AUDIOLOGY, 1998, 27 : 61 - 68
  • [47] Patient-specific skin dose evaluation in breast cancer radiotherapy: A Monte Carlo study
    Atarod, Maryam
    Shami, Nahid
    Pourmoghaddas, Amir
    Saeb, Mohsen
    RADIATION PHYSICS AND CHEMISTRY, 2025, 231
  • [48] THE IMPORTANCE OF PATIENT-SPECIFIC DOSE CALCULATIONS IN NUCLEAR MEDICINE
    Stabin, Michael G.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2008, 40 (07) : 527 - 532
  • [49] Patient-specific dose escalation with, consideration of radiobiological factors
    Hood, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S211 - S211
  • [50] Patient-specific dose estimation for pediatric chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    MEDICAL PHYSICS, 2008, 35 (12) : 5821 - 5828