Patient-specific dose correction for prostate postimplant evaluation with flexible timing of postimplant imaging

被引:0
|
作者
Luo, Wei [1 ]
Cheek, Denise [1 ]
St Clair, William [1 ]
Washington, Brien [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Lexington, KY 40536 USA
关键词
edema; flexible timing; optimal time; patient-specific dose correction; postimplant CT; COMPUTED-TOMOGRAPHY; SEED IMPLANT; INTERSTITIAL BRACHYTHERAPY; AMERICAN-ASSOCIATION; EDEMA; I-125; DOSIMETRY; RECOMMENDATIONS; PD-103; IMPACT;
D O I
10.1002/mp.15968
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The dosimetric effect of edema on prostate implants have long been realized, but large uncertainties still exist in the estimation of dose actually received by the prostate. This study attempted to develop a new method to accurately estimate dose delivered to the prostate accounting for the variation of prostate volume and seed distribution, edema half-lives, and times for postimplant evaluation. Methods and materials A series of prostate seed implants for Cs-131, Pd-103, and I-125 with various prostate volumes were simulated in a water phantom using the TG-43 algorithm on the Varian Eclipse treatment planning system. Dose analysis was performed to derive a quantitative relationship between the prostate peripheral dose and the prostate radius with the variation of prostate volume and seed distribution. Using this relationship to calculate dynamically, the total dose accumulated in the prostate (D-T) accounting for the variation of prostate volume and seed distribution and edema half-lives. Moreover, the total dose can be estimated statically based on the prostate volume that can be determined in a computerized tomography (CT) image taken at a time after implantation. The statically estimated total dose (D-CT) was compared with D-T to determine optimal imaging times as well as dose correction factors for other imaging times. Results An inverse power law was established between the prostate peripheral dose and prostate radius. The value of the power was 1.3 for Cs-131 and I-125, and 1.5 for Pd-103, respectively. D-T was derived dynamically using the inverse power law. Given the edema half-lives, T-E, of 4, 9.3, and 25 days and the volume expansion of 1.1 and 2.0 times of the prostate without edema, the optimal times for postimplant imaging were: 7, 9, and 16 days for T-E = 4 days; 10, 14, and 28 days for T-E = 9.3 days; and 12, 19, 45 days T-E = 25 days, for Cs-131, Pd-103, and I-125, respectively. D-CT calculated using the prostate volume determined on the optimal days agreed with D-T to 0.0%-1.8% and within 0.3% for most cases. For various prostate volumes, edema half-lives, and nonoptimal times, D-CT was able to achieve a 1% accuracy. Conclusion The postimplant dose calculation based on the proposed inverse power law for prostate seed implants with edema has improved the accuracy of postimplant dosimetry with accurate and patient-specific dose corrections accounting for prostate size, edema half-life, and postimplant imaging times. Optimal times for postimplant imaging have been accurately determined, and the high accuracy of postimplant dose calculation can be achieved for both optimal imaging times and nonoptimal imaging times.
引用
收藏
页码:6802 / 6812
页数:11
相关论文
共 50 条
  • [31] Construction of patient-specific computational models for organ dose estimation in radiological imaging
    Xie, Tianwu
    Akhavanallaf, Azadeh
    Zaidi, Habib
    MEDICAL PHYSICS, 2019, 46 (05) : 2403 - 2411
  • [32] Sensitivity of clinically relevant dosimetric parameters to contouring uncertainty in postimplant dosimetry of low-dose-rate prostate permanent seed brachytherapy
    Mashouf, Shahram
    Safigholi, Habib
    Merino, Tomas
    Soliman, Abraam
    Ravi, Ananth
    Morton, Gerard
    Song, William Y.
    BRACHYTHERAPY, 2016, 15 (06) : 774 - 779
  • [33] Feasibility of an MRI-only workflow for postimplant dosimetry of low-dose-rate prostate brachytherapy: Transition from phantoms to patients
    Nosrati, Reyhaneh
    Song, William Y.
    Wronski, Matthew
    Pejovic-Milic, Ana
    Morton, Gerard
    Stanisz, Greg J.
    BRACHYTHERAPY, 2019, 18 (06) : 863 - 874
  • [34] Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy
    Takahashi Y.
    Mori S.
    Kozuka T.
    Gomi K.
    Nose T.
    Tahara T.
    Oguchi M.
    Yamashita T.
    Radiation Medicine, 2006, 24 (2): : 133 - 138
  • [35] Establishment and Evaluation of Patient-Specific Virtual Ureteroscopy in Assisting Flexible Ureteroscopy for Urolithiasis
    Zhang, Yi
    Yu, Cheng-fan
    Zhang, Jun-hui
    Qiao, Lu-dong
    Yan, Wei
    Qin, Cai-peng
    SURGICAL INNOVATION, 2017, 24 (05) : 440 - 445
  • [36] A patient-specific scatter artifacts correction method
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [37] Quality indicators and technique for analyzing permanent I-125 prostate seed implants: Seven years postimplant dosimetry evaluation
    Marcu, Loredana G.
    Lawson, John M.
    Rutten, Thomas
    Gowda, Raghu
    MEDICAL PHYSICS, 2012, 39 (07) : 4123 - 4131
  • [38] Impact of neoadjuvant androgen deprivation therapy on postimplant prostate D90 and prostate volume after low-dose-rate brachytherapy for localized prostate cancer
    Owari, Takuya
    Tanaka, Nobumichi
    Nakai, Yasushi
    Miyake, Makito
    Anai, Satoshi
    Torimoto, Kazumasa
    Maesaka, Fumisato
    Asakawa, Isao
    Yamaki, Kaori
    Fuji, Tomomi
    Hasegawa, Masatoshi
    Fujimoto, Kiyohide
    INTERNATIONAL JOURNAL OF UROLOGY, 2022, 29 (02) : 143 - 151
  • [39] Patient-Specific Implants for Correction of Midfacial Aging
    Wang, Xin
    Chen, Xiaoping
    Zhao, Qiming
    Zhou, Zhuying
    Wu, Sihan
    Chen, Yue
    Wang, Xiaowei
    Huang, Xiaoxiang
    Long, Xiaohui
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (06) : 1784 - 1788
  • [40] FLEX: FLexible Transducer With External Tracking for Ultrasound Imaging With Patient-Specific Geometry Estimation
    China, Debarghya
    Feng, Ziwei
    Hooshangnejad, Hamed
    Sforza, Daniel
    Vagdargi, Prasad
    Bell, Muyinatu A. Lediju
    Uneri, Ali
    Sisniega, Alejandro
    Ding, Kai
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (04) : 1298 - 1307