Patient-specific dose correction for prostate postimplant evaluation with flexible timing of postimplant imaging

被引:0
|
作者
Luo, Wei [1 ]
Cheek, Denise [1 ]
St Clair, William [1 ]
Washington, Brien [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Lexington, KY 40536 USA
关键词
edema; flexible timing; optimal time; patient-specific dose correction; postimplant CT; COMPUTED-TOMOGRAPHY; SEED IMPLANT; INTERSTITIAL BRACHYTHERAPY; AMERICAN-ASSOCIATION; EDEMA; I-125; DOSIMETRY; RECOMMENDATIONS; PD-103; IMPACT;
D O I
10.1002/mp.15968
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The dosimetric effect of edema on prostate implants have long been realized, but large uncertainties still exist in the estimation of dose actually received by the prostate. This study attempted to develop a new method to accurately estimate dose delivered to the prostate accounting for the variation of prostate volume and seed distribution, edema half-lives, and times for postimplant evaluation. Methods and materials A series of prostate seed implants for Cs-131, Pd-103, and I-125 with various prostate volumes were simulated in a water phantom using the TG-43 algorithm on the Varian Eclipse treatment planning system. Dose analysis was performed to derive a quantitative relationship between the prostate peripheral dose and the prostate radius with the variation of prostate volume and seed distribution. Using this relationship to calculate dynamically, the total dose accumulated in the prostate (D-T) accounting for the variation of prostate volume and seed distribution and edema half-lives. Moreover, the total dose can be estimated statically based on the prostate volume that can be determined in a computerized tomography (CT) image taken at a time after implantation. The statically estimated total dose (D-CT) was compared with D-T to determine optimal imaging times as well as dose correction factors for other imaging times. Results An inverse power law was established between the prostate peripheral dose and prostate radius. The value of the power was 1.3 for Cs-131 and I-125, and 1.5 for Pd-103, respectively. D-T was derived dynamically using the inverse power law. Given the edema half-lives, T-E, of 4, 9.3, and 25 days and the volume expansion of 1.1 and 2.0 times of the prostate without edema, the optimal times for postimplant imaging were: 7, 9, and 16 days for T-E = 4 days; 10, 14, and 28 days for T-E = 9.3 days; and 12, 19, 45 days T-E = 25 days, for Cs-131, Pd-103, and I-125, respectively. D-CT calculated using the prostate volume determined on the optimal days agreed with D-T to 0.0%-1.8% and within 0.3% for most cases. For various prostate volumes, edema half-lives, and nonoptimal times, D-CT was able to achieve a 1% accuracy. Conclusion The postimplant dose calculation based on the proposed inverse power law for prostate seed implants with edema has improved the accuracy of postimplant dosimetry with accurate and patient-specific dose corrections accounting for prostate size, edema half-life, and postimplant imaging times. Optimal times for postimplant imaging have been accurately determined, and the high accuracy of postimplant dose calculation can be achieved for both optimal imaging times and nonoptimal imaging times.
引用
收藏
页码:6802 / 6812
页数:11
相关论文
共 50 条
  • [1] The impact of postimplant edema on the urethral dose in prostate brachytherapy
    Waterman, FM
    Dicker, AP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03): : 661 - 664
  • [2] CT AND MRI FUSION FOR POSTIMPLANT PROSTATE BRACHYTHERAPY EVALUATION
    Dehghan, Ehsan
    Le, Yi
    Lee, Junghoon
    Song, Daniel Y.
    Fichtinger, Gabor
    Prince, Jerry L.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 625 - 628
  • [3] How does postimplant edema effect the rectal dose in prostate brachytherapy?
    Dicker, AP
    Waterman, FM
    RADIOLOGY, 1999, 213P : 109 - 109
  • [4] Biologically effective dose for permanent prostate brachytherapy taking into account postimplant edema
    Van Gellekom, MPR
    Moerland, MA
    Kal, HB
    Battermann, JJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02): : 422 - 433
  • [5] Evaluation of interobserver differences in postimplant dosimetry following prostate brachytherapy and the efficacy of CT/MRI fusion imaging
    Manabu Aoki
    Atsunori Yorozu
    Takushi Dokiya
    Japanese Journal of Radiology, 2009, 27 : 342 - 347
  • [6] Evaluation of interobserver differences in postimplant dosimetry following prostate brachytherapy and the efficacy of CT/MRI fusion imaging
    Aoki, Manabu
    Yorozu, Atsunori
    Dokiya, Takushi
    JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (09): : 342 - 347
  • [7] Dosimetric evaluation of clinical target volume in the postimplant analysis of low-dose-rate brachytherapy for prostate cancer
    Nasser, Nicola J.
    Sappiatzer, Joshua
    Wang, Yinkun
    Borg, Jette
    Saibishkumar, Elantholi P.
    BRACHYTHERAPY, 2015, 14 (02) : 189 - 196
  • [8] Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy
    Prestidge, BR
    Bice, WS
    Kiefer, EJ
    Prete, JJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05): : 1111 - 1115
  • [9] Uncertainty in magnetic resonance imaging-based prostate postimplant dosimetry: Results of a 10-person human observer study, and comparisons with automatic postimplant dosimetry
    Sanders, Jeremiah W.
    Tang, Chad
    Kudchadker, Rajat J.
    Venkatesan, Aradhana M.
    Mok, Henry
    Hanania, Alexander N.
    Thames, Howard D.
    Bruno, Teresa L.
    Starks, Christine
    Santiago, Edwin
    Cunningham, Mandy
    Frank, Steven J.
    BRACHYTHERAPY, 2023, 22 (06) : 822 - 832
  • [10] INTRAOPERATIVE POSTIMPLANT DOSIMETRY USING TOMOSYNTHESIS IN LOW-DOSE RATE PROSTATE BRACHYTHERAPY
    Carrier, J-F.
    Brunet-Benkhoucha, M.
    Beliveau-Nadeau, D.
    Taussky, D.
    Donath, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S58 - S58