Sheath current characteristic and its reduction on underground power cable systems

被引:0
|
作者
Jung, CK [1 ]
Lee, JB [1 ]
Kang, JW [1 ]
Wang, XH [1 ]
Song, YH [1 ]
机构
[1] Wonkwang Univ, Dept Elect Engn, Iksan, South Korea
关键词
underground power cable; sheath circulating current; sheath current reduction;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Sheath current causes the sheath loss and can reduce the permissible current of the power cable transmission system. High sheath current is usually caused by the mixed burying formation of the cable, different length between sections, poor connection of the bonding leads, and connection of distribution cable on the transmission system. This paper analyses the characteristics of the sheath circulating current at various conditions and presents a useful method to reduce the sheath current in a mixed buying formation system. It can effectively reduce the current by up to 90%. The method is validated by the practical measurements and simulation using ATP, and also adopted in actual system. In addition, a special equipment is designed in this paper to measure and analyze the sheath circulating current. It can measure and analyze nine currents at a single time.
引用
收藏
页码:2562 / 2569
页数:8
相关论文
共 50 条
  • [41] TRENDS IN UNDERGROUND RESIDENTIAL DISTRIBUTION CABLE SYSTEMS
    MACKEVICH, JP
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1989, 25 (01) : 181 - 185
  • [42] CHEMICAL MOISTURE BARRIER CABLE FOR UNDERGROUND SYSTEMS
    BOW, KE
    SNOW, JH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 1942 - 1949
  • [43] Autonomous robotic monitoring of underground cable systems
    Jiang, B
    Sample, AP
    Wistort, RM
    Mamishev, AV
    2005 12TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS, 2005, : 673 - 679
  • [44] VOLTAGE BETWEEN SHEATH AND CABLE CONDUCTOR DUE TO SHORT-CIRCUIT CURRENT IN A POWER LINE.
    Krakowski, M.
    Archiwum Elektrotechniki (Warsaw), 1974, 23 (03): : 545 - 553
  • [45] SERIES-IMPEDANCE OF UNDERGROUND CABLE SYSTEMS
    MACHADO, VM
    DASILVA, JFB
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1334 - 1340
  • [46] Sheath Induced Over-Voltage Characteristic in 220 kV Power Cable Under Lightning Over-Voltage
    Li, Boyi
    Cui, Houkun
    An, Zengjun
    Rui, Haoran
    Zhao, Tao
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING (EAME 2017), 2017, 86 : 48 - 50
  • [47] Loss characteristic analysis of high capacity HTS DC power cable considering harmonic current
    Kim, J. G.
    Kim, D. W.
    Kim, A. R.
    Park, M.
    Yu, I. K.
    Kim, S. H.
    Sim, K. D.
    Cho, J. W.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2010, 470 (20): : 1592 - 1596
  • [48] Thermal Aging Evaluation of XLPE Power Cable by Using Multidimensional Characteristic Analysis of Leakage Current
    Liu, Yong
    Wang, Hao
    Zhang, Han
    Du, Boxue
    POLYMERS, 2022, 14 (15)
  • [49] Underground cable laying - proposal to lay power cable and OFC in one trench
    Manjunath, Matam
    Gaur, Ankita Singh
    Pissurlenkar, Soumik
    2014 EIGHTEENTH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2014,
  • [50] CORROSION SURVEYS OF LEAD SHEATH CABLE IN A NONSTRAY CURRENT AREA
    CANTWELL, GH
    MATERIALS PROTECTION, 1969, 8 (12): : 33 - &