Sheath current characteristic and its reduction on underground power cable systems

被引:0
|
作者
Jung, CK [1 ]
Lee, JB [1 ]
Kang, JW [1 ]
Wang, XH [1 ]
Song, YH [1 ]
机构
[1] Wonkwang Univ, Dept Elect Engn, Iksan, South Korea
关键词
underground power cable; sheath circulating current; sheath current reduction;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Sheath current causes the sheath loss and can reduce the permissible current of the power cable transmission system. High sheath current is usually caused by the mixed burying formation of the cable, different length between sections, poor connection of the bonding leads, and connection of distribution cable on the transmission system. This paper analyses the characteristics of the sheath circulating current at various conditions and presents a useful method to reduce the sheath current in a mixed buying formation system. It can effectively reduce the current by up to 90%. The method is validated by the practical measurements and simulation using ATP, and also adopted in actual system. In addition, a special equipment is designed in this paper to measure and analyze the sheath circulating current. It can measure and analyze nine currents at a single time.
引用
收藏
页码:2562 / 2569
页数:8
相关论文
共 50 条
  • [21] Current status and technology trends of cable systems for power transmission
    Ebinuma Y.
    IEEJ Transactions on Power and Energy, 2020, 140 (04) : 239 - 242
  • [22] TEMPERATURE CALCULATION OF CONDUCTORS IN UNDERGROUND POWER CABLE
    KIMURA, S
    TSURU, M
    ELECTRICAL ENGINEERING IN JAPAN, 1966, 86 (11) : 24 - &
  • [23] Thermal analysis of underground power cable system
    Monika Rerak
    Paweł Ocłoń
    Journal of Thermal Science, 2017, 26 : 465 - 471
  • [24] Economic Optimization of an Underground Power Cable Installation
    Cichy, Andrzej
    Sakowicz, Bartosz
    Kaminski, Marek
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (03) : 1124 - 1133
  • [25] Thermal Analysis of Underground Power Cable System
    Monika Rerak
    Pawe? Oc?oń
    JournalofThermalScience, 2017, 26 (05) : 465 - 471
  • [26] Thermal Analysis of Underground Power Cable System
    Rerak, Monika
    Oclon, Pawel
    JOURNAL OF THERMAL SCIENCE, 2017, 26 (05) : 465 - 471
  • [27] Overheating of Underground Power Cable Line Due to Its Partial Exposition to Solar Radiation
    Czapp, Stanislaw
    Ratkowski, Filip
    Szultka, Seweryn
    Tomaszewski, Adam
    2019 24TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2019, : 396 - 400
  • [28] Fault location algorithm on underground power cable systems using noise cancellation technique
    Jung, Chae-kyun
    Lee, Jong-beom
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 218 - +
  • [29] Power Systems Inspection Robot for Contactless Busbar Voltage Measurement and Underground Cable Tracking
    Barnett, Shaun B.
    Saha, Akshay K.
    2018 IEEE PES/IAS POWERAFRICA CONFERENCE, 2018, : 226 - 231
  • [30] TRANSIENT PILOT-CABLE INDUCTION FROM UNDERGROUND POWER-TRANSMISSION SYSTEMS
    WEDEPOHL, LM
    WILCOX, DJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1979, 126 (12): : 1269 - 1274