PATIENT RADIATION DOSES IN CARDIAC COMPUTED TOMOGRAPHY: COMPARISON OF PUBLISHED RESULTS WITH PROSPECTIVE AND RETROSPECTIVE ACQUISITION

被引:11
|
作者
Efstathopoulos, E. P. [1 ]
Pantos, I. [1 ,2 ]
Thalassinou, S. [1 ,3 ]
Argentos, S. [1 ]
Kelekis, N. L. [1 ]
Zografos, T. [2 ]
Panayiotakis, G. [3 ]
Katritsis, D. G. [2 ]
机构
[1] Univ Athens, Gen Univ Hosp ATTIKON, Sch Med, Dept Radiol 2, GR-12462 Athens, Greece
[2] Athens Euroclin, Athens, Greece
[3] Univ Patras, Dept Med Phys, Patras, Greece
关键词
CT CORONARY-ANGIOGRAPHY; TUBE CURRENT MODULATION; IMAGE QUALITY; DUAL-SOURCE; DIAGNOSTIC-ACCURACY; HEART-RATE; SPIRAL CT; EXPOSURE; REDUCTION; ARTERIES;
D O I
10.1093/rpd/ncq602
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Prospective ECG triggering has the potential of reducing radiation exposure while maintaining diagnostic accuracy of cardiac computed tomography (CT). The aim of this study is to review patient radiation doses associated with coronary artery calcium scoring (CACS) and CT coronary angiography (CTCA) and to compare results between prospective and retrospective acquisition schemes. Patient radiation doses from CACS and CTCA were extracted from 67 relevant studies. Mean effective dose for CACS and CTCA with prospective ECG triggering is significantly lower than retrospective acquisition, 0.9 +/- 0.4 vs. 3.1 +/- 1.4 mSv, p < 0.001, and 3.4 +/- 1.4 vs. 11.1 +/- 5.4 mSv, p < 0.001, respectively. In both cardiac CT examinations, application of dose modulation techniques result in significantly lower doses in retrospective schemes, however, even with dose modulation, retrospective acquisition is associated with significantly higher doses than prospective acquisition. The number of slices acquired per rotation and the number of X-ray sources of the CT scanner (single or dual source) do not have a significant effect on patient dose.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [21] Radiation Dose and Safety in Cardiac Computed Tomography
    Gerber, Thomas C.
    Kantor, Birgit
    McCollough, Cynthia H.
    CARDIOLOGY CLINICS, 2009, 27 (04) : 665 - +
  • [22] Radiation Exposure From Cardiac Computed Tomography
    Gosling, Oliver E.
    Roobottom, Carl A.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) : 1201 - 1202
  • [23] Radiation doses to emergency department patients undergoing computed tomography
    Worrall, James C.
    Jama, Sadia
    Stiell, Ian G.
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2014, 16 (06) : 477 - 484
  • [24] Saving the patient the radiation: no need for ECG-gating during cardiac computed tomography
    Ector, Joris
    Heidbuchel, Hein
    EUROPACE, 2010, 12 (08): : 1053 - 1054
  • [25] ESTIMATION OF RADIATION DOSES FROM ABDOMINAL COMPUTED TOMOGRAPHY SCANS
    Lahham, Adnan
    ALMasri, Hussein
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 235 - 240
  • [26] Assessment of Radiation doses to Paediatric Patients in Computed Tomography Procedures
    Alzimami, Khalid
    POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 344 - 348
  • [27] ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA
    Ngaile, J. E.
    Msaki, P. K.
    Suleiman, S. A.
    Chuma, F. M.
    Muhogora, W. E.
    Jusabani, A. M.
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (02) : 63 - 77
  • [28] Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography
    Blankstein, Ron
    Shah, Amar
    Pale, Rodrigo
    Abbara, Suhny
    Bezerra, Hiram
    Bolen, Michael
    Mamuya, Wilfred S.
    Hoffmann, Udo
    Brady, Thomas J.
    Cury, Ricardo C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08): : 1168 - 1173
  • [29] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    DeFrance, Tony
    Dubois, Eric
    Gebow, Dan
    Ramirez, Alex
    Wolf, Florian
    Feuchtner, Gudrun M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01): : 99 - 107
  • [30] Patient Doses in Multi-Detector Computed Tomography (MDCT)
    Ganesh, T.
    JOURNAL OF MEDICAL PHYSICS, 2007, 32 (04) : 187 - 188