Simultaneous measurements of liquid velocity and temperature for high pressure and high temperature liquid single phase flows

被引:2
|
作者
Francois, Fabrice [1 ]
Kledy, Michel [2 ]
Barre, Stephane [3 ]
Djeridi, Henda [3 ]
机构
[1] CEA Cadarache, Inst Rech Syst Nucl Prod Energie Bas Carbone, F-13108 St Paul Les Durance, France
[2] ECM Technol, F-38029 Grenoble 2, France
[3] Univ Grenoble Alpes, Grenoble INP, CNRS, Lab Ecoulements Geophys Ind, Domaine Univ, F-38400 St Martin Dheres, France
关键词
TURBULENT; WIRES;
D O I
10.1016/j.nucengdes.2020.110587
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Forced convective boiling is of great interest for several applications in the power and process industry, particularly in nuclear plants. Under certain nominal, incidental or accidental conditions, boiling crisis (Departure from Nucleate Boiling) may occur resulting in the melting of the heated surface. An accurate prediction of the conditions leading to the occurrence of this phenomenon is then essential. We believe that such an objective unreachable unless one provides a good and accurate description of the associated two-phase flow. To achieve this goal, local parameters e.g. void fraction, vapor and liquid velocities, liquid temperature…, need to be measured within the range of interest, which mainly concerns the high pressure and high temperature convective boiling flows. In this work, we only focus on the liquid velocity and temperature measurements and we propose to use thermal anemometry for performing such measurements. However, due to the high complexity of those flows, we have developed a two-steps strategy. Indeed, before using such an experimental technic for boiling flows, we need first to check the feasibility of this method for characterizing single-phase heated flows. Measurements for boiling flows will be performed in a second step, which is beyond the scope of the present paper. We applied the multiple overheating method for simultaneous measurement of the liquid velocity and the liquid temperature using a single sensor. If this methodology has already been used for gas flows measurements (Bestion et al., 1983; Barre et al., 1992, 1994), as far as we know, this work is the first attempt for liquid flows. We conducted experiments in a circular heated tube whose inner diameter and length are 19.2 mm and 3.5 m, respectively. The sensor (hot wire d~5 µm) has been operated with the Constant Current mode (CCA). To consider for temperature effect on velocity calibration, we proposed a new non-dimensional representation of the calibration curve. We also improve the frequency response of the probe using a digital compensation method. Preliminary tests for single-phase flows confirmed that it was possible to get very accurate measurements of mean and fluctuating liquid velocity profiles as well as mean temperature profiles. We have carefully analyzed the experimental uncertainties, which are close to 0.5 °C for the liquid temperature and ±5% for the liquid velocity. © 2020 Elsevier B.V.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] The acoustic velocity, refractive index, and equation of state of liquid ammonia dihydrate under high pressure and high temperature
    Ma, Chunli
    Wu, Xiaoxin
    Huang, Fengxian
    Zhou, Qiang
    Li, Fangfei
    Cui, Qiliang
    JOURNAL OF CHEMICAL PHYSICS, 2012, 137 (10):
  • [32] Novel technique to estimate velocity in liquid steel and in other high temperature liquid metals
    Mikrovas, Anthony C.
    Argyropoulos, Stavros A.
    Iron & Steelmaker (I&SM), 1993, 20 (10): : 85 - 96
  • [33] VELOCITY OF SOUND IN LIQUID OXYGEN AND LIQUID NITROGEN AS A FUNCTION OF TEMPERATURE AND PRESSURE
    VANITTERBEEK, A
    VANDAEL, W
    PHYSICA, 1962, 28 (09): : 861 - &
  • [34] Characteristics of gas-liquid two-phase flow at high temperature and high pressure in the pipeline
    Hu Z.-X.
    Lian S.-J.
    Li Q.-F.
    Ma X.-H.
    Hao T.-T.
    Lan Z.
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2022, 36 (01): : 36 - 45
  • [35] Prediction of the liquid-liquid phase equilibria for polydisperse polyethylene solutions under conditions of high temperature and pressure
    Haruki, Masashi
    Adachi, Kotaro
    Fujikawa, Shohei
    Kihara, Shin-ichi
    Takishima, Shigeki
    FLUID PHASE EQUILIBRIA, 2016, 412 : 135 - 144
  • [36] High temperature injection in capillary high temperature liquid chromatography
    Molander, P
    Ommundsen, E
    Greibrokk, T
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (08) : 612 - 619
  • [37] Liquid matter at high temperature
    Hondros, ED
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2003, 22 (5-6) : 233 - 235
  • [38] High temperature injection in capillary high temperature liquid chromatography
    Department of Chemistry , University of Oslo, P.O. Box 1033, Blindern, N-0315 Oslo, Norway
    不详
    J Microcolumn Sep, 8 (612-619):
  • [39] MEASUREMENTS OF HIGH-TEMPERATURE VISCOSITIES OF LIQUID BORON TRIOXIDE
    SRINIVASAN, NS
    JUNEJA, JM
    SEETHARAMAN, S
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1994, 25 (04): : 877 - 881
  • [40] Pressure and temperature induced crystallization of liquid phosphorus under high pressure
    Morishita, T
    CHEMICAL PHYSICS LETTERS, 2003, 380 (3-4) : 342 - 346