Simultaneous measurements of liquid velocity and temperature for high pressure and high temperature liquid single phase flows

被引:2
|
作者
Francois, Fabrice [1 ]
Kledy, Michel [2 ]
Barre, Stephane [3 ]
Djeridi, Henda [3 ]
机构
[1] CEA Cadarache, Inst Rech Syst Nucl Prod Energie Bas Carbone, F-13108 St Paul Les Durance, France
[2] ECM Technol, F-38029 Grenoble 2, France
[3] Univ Grenoble Alpes, Grenoble INP, CNRS, Lab Ecoulements Geophys Ind, Domaine Univ, F-38400 St Martin Dheres, France
关键词
TURBULENT; WIRES;
D O I
10.1016/j.nucengdes.2020.110587
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Forced convective boiling is of great interest for several applications in the power and process industry, particularly in nuclear plants. Under certain nominal, incidental or accidental conditions, boiling crisis (Departure from Nucleate Boiling) may occur resulting in the melting of the heated surface. An accurate prediction of the conditions leading to the occurrence of this phenomenon is then essential. We believe that such an objective unreachable unless one provides a good and accurate description of the associated two-phase flow. To achieve this goal, local parameters e.g. void fraction, vapor and liquid velocities, liquid temperature…, need to be measured within the range of interest, which mainly concerns the high pressure and high temperature convective boiling flows. In this work, we only focus on the liquid velocity and temperature measurements and we propose to use thermal anemometry for performing such measurements. However, due to the high complexity of those flows, we have developed a two-steps strategy. Indeed, before using such an experimental technic for boiling flows, we need first to check the feasibility of this method for characterizing single-phase heated flows. Measurements for boiling flows will be performed in a second step, which is beyond the scope of the present paper. We applied the multiple overheating method for simultaneous measurement of the liquid velocity and the liquid temperature using a single sensor. If this methodology has already been used for gas flows measurements (Bestion et al., 1983; Barre et al., 1992, 1994), as far as we know, this work is the first attempt for liquid flows. We conducted experiments in a circular heated tube whose inner diameter and length are 19.2 mm and 3.5 m, respectively. The sensor (hot wire d~5 µm) has been operated with the Constant Current mode (CCA). To consider for temperature effect on velocity calibration, we proposed a new non-dimensional representation of the calibration curve. We also improve the frequency response of the probe using a digital compensation method. Preliminary tests for single-phase flows confirmed that it was possible to get very accurate measurements of mean and fluctuating liquid velocity profiles as well as mean temperature profiles. We have carefully analyzed the experimental uncertainties, which are close to 0.5 °C for the liquid temperature and ±5% for the liquid velocity. © 2020 Elsevier B.V.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] An in situ technique to visualize temperature and velocity fields in liquid biotechnical substances at high pressure
    Pehl, M
    Delgado, A
    ADVANCES IN HIGH PRESSURE BIOSCIENCE AND BIOTECHNOLOGY, 1999, : 519 - 522
  • [22] VELOCITY OF SOUND MEASUREMENTS IN HIGH-PRESSURE, HIGH-TEMPERATURE STEAM
    WOODBURN, J
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1960, 32 (11): : 1511 - 1511
  • [23] NMR IN LIQUID SELENIUM TO HIGH-TEMPERATURE AND PRESSURE
    WARREN, WW
    DUPREE, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (03): : 385 - 385
  • [24] Development of a sensor to measure velocity in high temperature liquid metals
    Argyropoulos, SA
    LIGHT METALS 2001, 2001, : 1201 - 1208
  • [25] MEASUREMENT OF VELOCITY IN HIGH-TEMPERATURE LIQUID-METALS
    MIKROVAS, AC
    ARGYROPOULOS, SA
    METALLURGICAL TRANSACTIONS B-PROCESS METALLURGY, 1993, 24 (06): : 1009 - 1022
  • [26] Measuring velocity in high-temperature liquid metals: a review
    Argyropoulos, SA
    SCANDINAVIAN JOURNAL OF METALLURGY, 2001, 30 (05) : 273 - 285
  • [27] ULTRASONIC PULSE TRANSMISSION ECHO TECHNIQUE FOR SOUND-VELOCITY MEASUREMENTS IN HIGH-TEMPERATURE AND HIGH-PRESSURE LIQUID-METALS
    SUZUKI, K
    FUJIWAKA, S
    INUTAKE, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1985, 24 : 79 - 81
  • [28] EXAFS study on liquid gallium under high pressure and high temperature
    Comez, L
    Di Cicco, A
    Minicucci, M
    Tossici, R
    Itié, JP
    Polian, A
    JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 (02) : 776 - 778
  • [29] Electride transition in liquid aluminum under high pressure and high temperature
    Qin, Yuxin
    Zhang, Xiaoliang
    Zhou, Shiting
    Wang, Yangyang
    Chen, Gaoyuan
    Dai, Chen-Min
    Li, Weiwei
    Li, Cong
    JOURNAL OF CHEMICAL PHYSICS, 2025, 162 (01):
  • [30] HIGH PRESSURE HIGH TEMPERATURE UNIT FOR LIQUID-SOLID REACTIONS
    DRESHER, WH
    KANEKO, TM
    FASSELL, WM
    WADSWORTH, ME
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1955, 47 (09): : 1681 - 1685