Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study

被引:142
|
作者
Buckinx, Fanny [1 ,2 ]
Reginster, Jean-Yves [1 ,3 ,4 ,5 ]
Dardenne, Nadia [1 ,2 ]
Croisiser, Jean-Louis [6 ]
Kaux, Jean-Francois [6 ,7 ]
Beaudart, Charlotte [1 ,2 ]
Slomian, Justine [1 ,2 ]
Bruyere, Olivier [1 ,2 ,6 ]
机构
[1] Univ Liege, Dept Publ Hlth Epidemiol & Hlth Econ, B-4000 Liege, Belgium
[2] Univ Liege, Support Unit Epidemiol & Biostat, B-4000 Liege, Belgium
[3] CHU Liege, Bone Metab Dept, B-4000 Liege, Belgium
[4] CHU Liege, Dept Publ Hlth, B-4000 Liege, Belgium
[5] CHU Liege, Bone & Cartilage Metab Dept, B-4000 Liege, Belgium
[6] Univ Liege, Dept Motr Sci, B-4000 Liege, Belgium
[7] CHU Liege, Dept Phys Med & Funct Rehabil, B-4000 Liege, Belgium
来源
关键词
BIA; Muscle mass; Appendicular lean mass; DXA; BODY-COMPOSITION; STRENGTH MEASUREMENT; CYSTIC-FIBROSIS; GRIP STRENGTH; WHOLE-BODY; FAT MASS; RELIABILITY; VALIDITY; ADULTS; DXA;
D O I
10.1186/s12891-015-0510-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. Methods: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. Results: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95% CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95% CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95% CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 +/- 1.39 kg/m(2) with BIA and 7.34 +/- 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. Conclusions: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Validity and agreement between dual-energy X-ray absorptiometry, anthropometry and bioelectrical impedance in the estimation of fat mass in young adults
    Mecherques-Carini, Malek
    Albaladejo-Saura, Mario
    Vaquero-Cristobal, Raquel
    Baglietto, Nicolas
    Esparza-Ros, Francisco
    FRONTIERS IN NUTRITION, 2024, 11
  • [32] Bioelectrical impedance analysis as an alternative to dual-energy x-ray absorptiometry in the assessment of fat mass and appendicular lean mass in patients with obesity
    Ballesteros-Pomar, Maria D.
    Gonzalez-Arnaiz, Elena
    Pintor-de-la Maza, Begona
    Barajas-Galindo, David
    Ariadel-Cobo, Diana
    Gonzalez-Roza, Lucia
    Cano-Rodriguez, Isidoro
    NUTRITION, 2022, 93
  • [33] Comparison of the ability between dual-energy X-ray absorptiometry and bioelectrical impedance analysis for diagnosing low skeletal muscle mass and sarcopenia in patients with chronic liver disease
    Tamura, Yuki
    Saeki, Chisato
    Kanai, Tomoya
    Kiryu, Sachie
    Nakano, Masanori
    Oikawa, Tsunekazu
    Torisu, Yuichi
    Saruta, Masayuki
    Tsubota, Akihito
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2025, 40 (01) : 274 - 281
  • [34] Comparison Of Body Fat Assessment Procedures: Bioelectrical Impedance And Dual Energy X-ray Absorptiometry
    Turner, Lori W.
    Cole, Mary
    Wallace, Lorraine S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S298 - S299
  • [35] Comparison of body composition measures assessed by bioelectrical impedance analysis versus dual-energy X-ray absorptiometry in the United Kingdom Biobank
    Feng, Qi
    Besevic, Jelena
    Conroy, Megan
    Omiyale, Wemimo
    Lacey, Ben
    Allen, Naomi
    CLINICAL NUTRITION ESPEN, 2024, 63 : 214 - 225
  • [36] Comparison of Body Composition by Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry in Hispanic Diabetics
    Batech, Michael
    Beeson, W. Lawrence
    Schultz, Eloy
    Salto, Lorena
    Firek, Anthony
    DeLeon, Marino
    Balcazar, Hector
    Cordero-MacIntyre, Zaida
    FASEB JOURNAL, 2010, 24
  • [37] Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry
    Rae, L. S.
    Vankan, D. M.
    Rand, J. S.
    Flickinger, E. A.
    Ward, L. C.
    VETERINARY JOURNAL, 2016, 212 : 65 - 70
  • [38] Comparison of Percent Body Fat Determined by Bioelectrical Impedance Analysis and Dual Energy X-ray Absorptiometry in Children
    Rude, Katie
    Fetterman, Meghan
    Dixon, Curt B.
    Andreacci, Joseph L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 617 - 617
  • [39] Comparison of segmental body composition estimated by bioelectrical impedance analysis and dual-energy X-ray absorptiometry
    Wingo, Brooks C.
    Barry, Valene Garr
    Ellis, Amy C.
    Gower, Barbara A.
    CLINICAL NUTRITION ESPEN, 2018, 28 : 141 - 147
  • [40] BIOELECTRICAL-IMPEDANCE ANALYSIS AND DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MONITOR NUTRITIONAL-STATUS
    STALL, S
    GINSBERG, NS
    LYNN, RI
    ZABETAKIS, PM
    PERITONEAL DIALYSIS INTERNATIONAL, 1995, 15 (05): : S59 - S62