Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study

被引:142
|
作者
Buckinx, Fanny [1 ,2 ]
Reginster, Jean-Yves [1 ,3 ,4 ,5 ]
Dardenne, Nadia [1 ,2 ]
Croisiser, Jean-Louis [6 ]
Kaux, Jean-Francois [6 ,7 ]
Beaudart, Charlotte [1 ,2 ]
Slomian, Justine [1 ,2 ]
Bruyere, Olivier [1 ,2 ,6 ]
机构
[1] Univ Liege, Dept Publ Hlth Epidemiol & Hlth Econ, B-4000 Liege, Belgium
[2] Univ Liege, Support Unit Epidemiol & Biostat, B-4000 Liege, Belgium
[3] CHU Liege, Bone Metab Dept, B-4000 Liege, Belgium
[4] CHU Liege, Dept Publ Hlth, B-4000 Liege, Belgium
[5] CHU Liege, Bone & Cartilage Metab Dept, B-4000 Liege, Belgium
[6] Univ Liege, Dept Motr Sci, B-4000 Liege, Belgium
[7] CHU Liege, Dept Phys Med & Funct Rehabil, B-4000 Liege, Belgium
来源
关键词
BIA; Muscle mass; Appendicular lean mass; DXA; BODY-COMPOSITION; STRENGTH MEASUREMENT; CYSTIC-FIBROSIS; GRIP STRENGTH; WHOLE-BODY; FAT MASS; RELIABILITY; VALIDITY; ADULTS; DXA;
D O I
10.1186/s12891-015-0510-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. Methods: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. Results: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95% CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95% CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95% CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 +/- 1.39 kg/m(2) with BIA and 7.34 +/- 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. Conclusions: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: a cross sectional study
    Hanen Samouda
    Jérémie Langlet
    BMC Endocrine Disorders, 22
  • [22] Fat-free mass by bioelectrical impedance vs dual-energy X-ray absorptiometry (DXA)
    De Lorenzo, A
    Sorge, SP
    Iacopino, L
    Andreoli, A
    De Luca, PP
    Sasso, GF
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 739 - 741
  • [23] Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: a cross sectional study
    Samouda, Hanen
    Langlet, Jeremie
    BMC ENDOCRINE DISORDERS, 2022, 22 (01)
  • [24] Segmental Lean Body Mass Values Determined by Dual Energy X-ray Absorptiometry and Multifrequency-Bioelectrical Impedance Analysis
    Cutrufello, Paul T.
    Dixon, Curt B.
    Andreacci, Joseph L.
    Zavorsky, Gerald S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 615 - 616
  • [25] Different calculations of fat-free mass by bioelectrical impedance analysis: Comparison with Dual-Energy X-Ray Absorptiometry
    Varlet-Marie, E.
    Grubka, E.
    Karafiat, M.
    Fedou, C.
    de Mauverger, E. Raynaud
    Brun, J. -F.
    SCIENCE & SPORTS, 2009, 24 (3-4) : 202 - 206
  • [26] Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analysis are Beneficial Tools for Measuring the Trunk Muscle Mass of Patients with Low Back Pain
    Fujimoto, Kazuki
    Inage, Kazuhide
    Eguchi, Yawara
    Orita, Sumihisa
    Toyoguchi, Toru
    Yamauchi, Kazuyo
    Suzuki, Miyako
    Kubota, Go
    Sainoh, Takeshi
    Sato, Jun
    Shiga, Yasuhiro
    Abe, Koki
    Kanamoto, Hirohito
    Inoue, Masahiro
    Kinoshita, Hideyuki
    Norimoto, Masaki
    Umimura, Tomotaka
    Koda, Masao
    Furuya, Takeo
    Maki, Satoshi
    Akazawa, Tsutomu
    Terakado, Atsushi
    Takahashi, Kazuhisa
    Ohtori, Seiji
    SPINE SURGERY AND RELATED RESEARCH, 2019, 3 (04): : 335 - 341
  • [27] Comparison between dual-energy x-ray absorptiometry and bioelectrical impedance for body composition measurements in adults with chronic kidney disease: A cross-sectional, longitudinal, multi-treatment analysis
    Bellafronte, Natalia Tomborelli
    Diani, Luisa Maria
    Vega-Piris, Lorena
    Barril Cuadrado, Guillermina
    Chiarello, Paula Garcia
    NUTRITION, 2021, 82
  • [28] Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry
    Katharina Mally
    Jens Trentmann
    Martin Heller
    Manuela Dittmar
    European Journal of Applied Physiology, 2011, 111 : 1879 - 1887
  • [29] Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry
    Mally, Katharina
    Trentmann, Jens
    Heller, Martin
    Dittmar, Manuela
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (08) : 1879 - 1887
  • [30] Explaining Segmental Lean Soft Tissue Discrepancies Between Bioelectrical Impedance Analysis And Dual-Energy X-Ray Absorptiometry
    Stratton, Matthew T.
    Harty, Patrick S.
    Moore, M. Lane
    Griffiths, Nelson
    Dellinger, Jacob R.
    Benavides, Marqui L.
    Adamson, Brian T.
    Tinsley, Grant M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 877 - 877