Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study

被引:142
|
作者
Buckinx, Fanny [1 ,2 ]
Reginster, Jean-Yves [1 ,3 ,4 ,5 ]
Dardenne, Nadia [1 ,2 ]
Croisiser, Jean-Louis [6 ]
Kaux, Jean-Francois [6 ,7 ]
Beaudart, Charlotte [1 ,2 ]
Slomian, Justine [1 ,2 ]
Bruyere, Olivier [1 ,2 ,6 ]
机构
[1] Univ Liege, Dept Publ Hlth Epidemiol & Hlth Econ, B-4000 Liege, Belgium
[2] Univ Liege, Support Unit Epidemiol & Biostat, B-4000 Liege, Belgium
[3] CHU Liege, Bone Metab Dept, B-4000 Liege, Belgium
[4] CHU Liege, Dept Publ Hlth, B-4000 Liege, Belgium
[5] CHU Liege, Bone & Cartilage Metab Dept, B-4000 Liege, Belgium
[6] Univ Liege, Dept Motr Sci, B-4000 Liege, Belgium
[7] CHU Liege, Dept Phys Med & Funct Rehabil, B-4000 Liege, Belgium
来源
关键词
BIA; Muscle mass; Appendicular lean mass; DXA; BODY-COMPOSITION; STRENGTH MEASUREMENT; CYSTIC-FIBROSIS; GRIP STRENGTH; WHOLE-BODY; FAT MASS; RELIABILITY; VALIDITY; ADULTS; DXA;
D O I
10.1186/s12891-015-0510-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. Methods: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. Results: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95% CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95% CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95% CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 +/- 1.39 kg/m(2) with BIA and 7.34 +/- 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. Conclusions: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study
    Fanny Buckinx
    Jean-Yves Reginster
    Nadia Dardenne
    Jean-Louis Croisiser
    Jean-François Kaux
    Charlotte Beaudart
    Justine Slomian
    Olivier Bruyère
    BMC Musculoskeletal Disorders, 16
  • [2] CONCORDANCE BETWEEN MUSCLE MASS ASSESSED BY BIOELECTRICAL IMPEDANCE ANALYSIS AND BY DUAL ENERGY X-RAY ABSORPTIOMETRY AMONG ELDERLY PEOPLE: A CROSS-SECTIONAL STUDY
    Buckinx, F.
    Reginster, J. -Y.
    Dardenne, N.
    Croisier, J. L.
    Kaux, J. F.
    Beaudart, C.
    Slomian, J.
    Bruyere, O.
    OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S53 - S53
  • [3] Concordance between muscle mass assessed by bioelectrical impedance analysis and by muscle ultrasound: a cross-sectional study in a cohort of patients on chronic hemodialysis
    Eman Nagy
    Emad Samaan
    Mohamed El-Gamal
    Muhammed Shamsuddin
    Samar Tharwat
    BMC Nephrology, 25
  • [4] Concordance between muscle mass assessed by bioelectrical impedance analysis and by muscle ultrasound: a cross-sectional study in a cohort of patients on chronic hemodialysis
    Nagy, Eman
    Samaan, Emad
    El-Gamal, Mohamed
    Shamsuddin, Muhammed
    Tharwat, Samar
    BMC NEPHROLOGY, 2024, 25 (01)
  • [5] Prognostic values of muscle mass assessed by dual-energy X-ray absorptiometry and bioelectrical impedance analysis in older patients with heart failure
    Saito, Hiroshi
    Matsue, Yuya
    Maeda, Daichi
    Kasai, Takatoshi
    Kagiyama, Nobuyuki
    Endo, Yoshiko
    Zoda, Masato
    Mizukami, Akira
    Yoshioka, Kenji
    Hashimoto, Tomoaki
    Ishikawa, Kazuya
    Minamino, Tohru
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2022, 22 (08) : 610 - 615
  • [6] Agreement Between Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry to Estimate Fat Mass in Hispanic Adults With Type 2 Diabetes Mellitus: A Cross-Sectional Study
    Castillo Castro, Carolina
    Gonzalez Arellanes, Rogelio
    Camacho Mondragon, Christian Giovanni
    Farfan Esponda, Heriberto Raul
    del Razo Olvera, Fabiola Mabel
    Aguilar Salinas, Carlos A.
    Martagon, Alexandro J.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2024, 17
  • [7] Comparison of prognostic values of muscle mass assessed by dual-energy X-ray absorptiometry and bioelectrical impedance analysis in old hospitalized patients with heart failure
    Saito, H.
    Matsue, Y.
    Kasai, T.
    Endo, Y.
    Mizukami, A.
    Yoshioka, K.
    Hashimoto, T.
    Ishikawa, K.
    Minamino, T.
    EUROPEAN JOURNAL OF HEART FAILURE, 2021, 23 : 169 - 169
  • [8] Bioelectrical Impedance Analysis And Dual-energy X-ray Absorptiometry Assessments Of Leg Mass Asymmetry In Firefighters
    Coleman, Adam V.
    Dewig, Hayden
    Mota, Jacob
    Gerstner, Gena
    Trivisonno, Abigail
    Blue, Malia
    Laffan, Megan
    Ryan, Eric
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 107 - 107
  • [9] Bone Mineral Content Prediction by Bioelectrical Impedance Analysis in Children and Adolescents Diagnosed with HIV Infection: Comparison with Dual Energy X-ray Absorptiometry: A Cross-Sectional Study
    de Castro, Joao Antonio Chula
    de Lima, Luiz Rodrigo Augustemak
    Silva, Diego Augusto Santos
    APPLIED SCIENCES-BASEL, 2022, 12 (23):
  • [10] Physiological And Anthropometric Predictors Of Discrepancies Between Bioelectrical Impedance Analysis And Dual-energy X-ray Absorptiometry
    Harty, Patrick S.
    Stratton, Matthew T.
    Griffiths, Nelson
    Moore, M. Lane
    Benavides, Marqui L.
    Dellinger, Jacob R.
    Adamson, Brian T.
    Tinsley, Grant M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 877 - 877