Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals

被引:53
|
作者
Liu, Zeng-Ding [1 ]
Liu, Ji-Kui [2 ]
Wen, Bo [2 ]
He, Qing-Yun [1 ]
Li, Ye [1 ,3 ]
Miao, Fen [1 ,3 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Peoples R China
[3] Chinese Acad Sci HICAS, Shenzhen Inst Adv Technol, Key Lab Hlth Informat, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
cuffless blood pressure; piezoelectric sensor; pressure pulse waveform; pulse transit time; multiparameter fusion; ARTERIAL TONOMETRY; DICROTIC NOTCH; PEAK DETECTION; ARRIVAL-TIME; LESS; PHOTOPLETHYSMOGRAPHY; DEVICE; FORM; PPG;
D O I
10.3390/s18124227
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pulse transit time (PTT) has received considerable attention for noninvasive cuffless blood pressure measurement. However, this approach is inconvenient to deploy in wearable devices because two sensors are required for collecting two-channel physiological signals, such as electrocardiogram and pulse wave signals. In this study, we investigated the pressure pulse wave (PPW) signals collected from one piezoelectric-induced sensor located at a single site for cuffless blood pressure estimation. Twenty-one features were extracted from PPW that collected from the radial artery, and then a linear regression method was used to develop blood pressure estimation models by using the extracted PPW features. Sixty-five middle-aged and elderly participants were recruited to evaluate the performance of the constructed blood pressure estimation models, with oscillometric technique-based blood pressure as a reference. The experimental results indicated that the mean +/- standard deviation errors for the estimated systolic blood pressure and diastolic blood pressure were 0.70 +/- 7.78 mmHg and 0.83 +/- 5.45 mmHg, which achieved a decrease of 1.33 +/- 0.37 mmHg in systolic blood pressure and 1.14 +/- 0.20 mmHg in diastolic blood pressure, compared with the conventional PTT-based method. The proposed model also demonstrated a high level of robustness in a maximum 60-day follow-up study. These results indicated that PPW obtained from the piezoelectric sensor has great feasibility for cuffless blood pressure estimation, and could serve as a promising method in home healthcare settings.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Development of System for Noninvasive Cuffless Estimation of Blood Pressure
    Anisimov, A. A.
    Ananyeva, A.
    PROCEEDINGS OF THE 2014 IEEE NW RUSSIA YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (ELCONRUSNW), 2014, : 19 - 22
  • [32] Cuffless blood pressure monitoring using hydrostatic pressure changes
    Shaltis, Phillip A.
    Reisner, Andrew T.
    Asada, H. Harry
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (06) : 1775 - 1777
  • [33] A novel dynamical approach in continuous cuffless blood pressure estimation based on ECG and PPG signals
    Sharifi, Iman
    Goudarzi, Sobhan
    Khodabakhshi, Mohammad Bagher
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2019, 97 : 143 - 151
  • [34] Windkessel Model-Based Cuffless Blood Pressure Estimation Using Continuous Wave Doppler Ultrasound System
    Jana, Biswabandhu
    Oswal, Kamal
    Mitra, Sankar
    Saha, Goutam
    Banerjee, Swapna
    IEEE SENSORS JOURNAL, 2020, 20 (17) : 9989 - 9999
  • [35] Novel Cuffless Blood Pressure Estimation Method Using a Bayesian Hierarchical Model
    He, Shan
    Dajani, Hilmi R.
    Bolic, Miodrag
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 898 - 901
  • [36] Noninvasive Cuffless Estimation of Blood Pressure using Photoplethysmography without Electrocardiograph Measurement
    Samria, Rohan
    Jain, Ridhi
    Jha, Ankita
    Saini, Sandeep
    Chowdhury, Shubhajit Roy
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 254 - 257
  • [37] Cuffless Blood Pressure Estimation using only Photoplethysmography based on Cardiovascular parameters
    Fukushima, Hayato
    Kawanaka, Haruki
    Bhuiyan, Md. Shoaib
    Oguri, Koji
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2132 - 2135
  • [38] Concatenated convolutional neural network model for cuffless blood pressure estimation using fuzzy recurrence properties of photoplethysmogram signals
    Ali Bahari Malayeri
    Mohammad Bagher Khodabakhshi
    Scientific Reports, 12
  • [39] Concatenated convolutional neural network model for cuffless blood pressure estimation using fuzzy recurrence properties of photoplethysmogram signals
    Malayeri, Ali Bahari
    Khodabakhshi, Mohammad Bagher
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [40] Cuffless Blood Pressure Devices
    Bradley, Corey K.
    Shimbo, Daichi
    Colburn, David Alexander
    Pugliese, Daniel N.
    Padwal, Raj
    Sia, Samuel K.
    Anstey, D. Edmund
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (05) : 380 - 387