Cuffless Blood Pressure Estimation using only Photoplethysmography based on Cardiovascular parameters

被引:0
|
作者
Fukushima, Hayato [1 ]
Kawanaka, Haruki [2 ]
Bhuiyan, Md. Shoaib [3 ]
Oguri, Koji [4 ]
机构
[1] Aichi Prefectural Univ, Grad Sch Informat Sci & Technol, Nagakute, Aichi, Japan
[2] Aichi Prefectural Univ, Sch Informat Sci & Technol, Nagakute, Aichi, Japan
[3] Suzuka Univ Med Sci, Fac Med Engn, Suzuka, Peoples R China
[4] Aichi Prefectural Univ, Sch Informat Sci & Technol, Aichi, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study provides cuffless blood pressure estimation. In general, blood pressure changes when the subject's condition changes, and it is important to estimate it continuously and noninvasively. In many previous studies, they used PTT (Pulse Transmission Time) for estimating. However, PTT needs both electrocardiogram and photoplethysmography to be measured. Our method needs only a finger type photoplethysmographic sensor for estimating. We use the features obtained only from photoplethysmography for estimating, instead of PTT obtained from electrocardiogram. The features used are accelerated plethysmography's waveform, Heart Rate Variability and the rate of photoplethysmography's drift. Blood pressure is modeled as the product of CO (Cardiac Output) and TPR (Total Peripheral Resistance) in general. Then, we estimated blood pressure as the product of eCO and eTPR estimated by proposed photoplethysmography's features with Stepwise multiple regression analysis. Therefore, our proposed method provides not only blood pressure, but also CO and TPR. As of result, we estimated blood pressure based on eCO and eTPR, and we obtained r = 0.71. Therefore, we could obtain the result closer to Finometer in accuracy.
引用
收藏
页码:2132 / 2135
页数:4
相关论文
共 50 条
  • [1] Cuffless blood pressure estimation using only a smartphone
    Kenta Matsumura
    Peter Rolfe
    Sogo Toda
    Takehiro Yamakoshi
    Scientific Reports, 8
  • [2] Cuffless blood pressure estimation using only a smartphone
    Matsumura, Kenta
    Rolfe, Peter
    Toda, Sogo
    Yamakoshi, Takehiro
    SCIENTIFIC REPORTS, 2018, 8
  • [3] Cuffless Blood Pressure Estimation Based on Monte Carlo Simulation Using Photoplethysmography Signals
    Haque, Chowdhury Azimul
    Kwon, Tae-Ho
    Kim, Ki-Doo
    SENSORS, 2022, 22 (03)
  • [4] Inverse-model-based cuffless blood pressure estimation using a single photoplethysmography sensor
    Suzuki, Arata
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (07) : 499 - 505
  • [5] Noninvasive Cuffless Estimation of Blood Pressure using Photoplethysmography without Electrocardiograph Measurement
    Samria, Rohan
    Jain, Ridhi
    Jha, Ankita
    Saini, Sandeep
    Chowdhury, Shubhajit Roy
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 254 - 257
  • [6] Photoplethysmography-based cuffless blood pressure estimation: an image encoding and fusion approach
    Liu, Yinsong
    Yu, Junsheng
    Mou, Hanlin
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (12)
  • [7] Features Extraction for Cuffless Blood Pressure Estimation by Autoencoder from Photoplethysmography
    Shimazaki, Shota
    Bhuiyan, Shoaib
    Kawanaka, Haruki
    Oguri, Koji
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2857 - 2860
  • [8] Cuffless Blood Pressure Estimation Using Calibrated Cardiovascular Dynamics in the Photoplethysmogram
    Samimi, Hamed
    Dajani, Hilmi R.
    BIOENGINEERING-BASEL, 2022, 9 (09):
  • [9] Cuffless Blood Pressure Estimation Using Single Channel Photoplethysmography: A Two-Step Method
    Khalid, Syed Ghufran
    Liu, Haipeng
    Zia, Tahir
    Zhang, Jufen
    Chen, Fei
    Zheng, Dingchang
    IEEE ACCESS, 2020, 8 : 58146 - 58154
  • [10] Parameters for Mean Blood Pressure Estimation Based on Electrocardiography and Photoplethysmography
    Spulak, Daniel
    Cmejla, Roman
    Fabian, Vratislav
    2011 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS (AE), 2011,