Fabrication of silicon PIN diode as proton energy detector

被引:4
|
作者
Cho, NI [1 ]
Nam, HG
Cha, KH
Lee, KH
Noh, SJ
机构
[1] Sun Moon Univ, Dept Elect Engn, Asan 336708, South Korea
[2] Dankook Univ, Dept Appl Phys, Seoul 140714, South Korea
关键词
silicon processing; proton sensor; leakage current; PIN diode;
D O I
10.1016/j.cap.2005.07.048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A proton detector device was fabricated by the conventional silicon process, including photolithography, oxidation, ion implantation, and metal electrode sputtering. The detection sensitivity of the PIN silicon detector was measured with varying the proton beam acceleration energy to the maximum value of 8 MeV. The detector device was aligned with the carbon collimator to expose the proton beam to the active area of the detector. The size of the collimator was 3 x 3 mm(2) with the square shape, which was the same shape as the detector active area. The flux density of the proton beam was fixed as 10 nA during the beam exposure. The reverse bias voltage of the device was 5 V. The reverse Current of the device Was Measured with a digital oscilloscope. The detection sensitivity for the proton energy of the diode showed the energy linearity of 10% until the proton energy of 5 MeV. The linear region may be expanded until 30 MeV when Cu attenuators were used with varying the Cu thickness. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [21] Thermal experiment of silicon PIN detector
    Chen Hong-Fei
    Zou Ji-Qing
    Shi Wei-Hong
    Zou Hong
    Hu Ran-Sheng
    Tian Da-Yu
    CHINESE PHYSICS C, 2008, 32 (10) : 820 - 824
  • [22] Study of silicon PIN diode responses to low energy gamma-rays
    Lee, S. C.
    Jeon, H. B.
    Kang, K. H.
    Park, H.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (10) : 1587 - 1590
  • [23] A filter technique for optimising the photon energy response of a silicon pin diode dosemeter
    Olsher, RH
    Eisen, Y
    RADIATION PROTECTION DOSIMETRY, 1996, 67 (04) : 271 - 279
  • [24] Study of silicon PIN diode responses to low energy gamma-rays
    S. C. Lee
    H. B. Jeon
    K. H. Kang
    H. Park
    Journal of the Korean Physical Society, 2016, 69 : 1587 - 1590
  • [25] Silicon PIN diode based electron-gamma coincidence detector system for Noble Gases monitoring
    Khrustalev, K.
    Popov, V. Yu
    Popov, Yu S.
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 237 - 239
  • [26] Silicon carbide PIN diode for tritium detection
    Eymeoud, Paul
    Biondo, Stephane
    Vervisch, Vanessa
    Ottaviani, Laurent
    Grillet, Nadia
    Roussel, Luc
    Coulie, Karine
    Palais, Olivier
    Darreon, Julien
    Vervisch, Wilfried
    VACUUM, 2024, 230
  • [27] Radiation Damage Study of a Silicon PIN Diode and Signal-to-Noise Ratio Measurement with a Proton Beam
    Kim, Y. I.
    Hyun, H. J.
    Kah, D. H.
    Kang, Heedong
    Kim, H. J.
    Kim, H. O.
    Park, H.
    Kim, Kyeryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 54 (05) : 2066 - 2070
  • [28] Signal-to-Noise Ratio Measurement and Radiation Damage Study of Silicon PIN Diode with a Proton Beam
    Kim, Y. I.
    Hyun, H. J.
    Kah, D. H.
    Kang, H. D.
    Kim, H. J.
    Kim, Kyeryung
    Park, H.
    Son, D. H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5160 - +
  • [29] Research on Silicon PIN Neutron Dose Detector
    Fan, Chao
    Yu, Min
    Yang, Fangdong
    Tian, Dayu
    Wang, Jinyan
    Jin, Yufeng
    CHINA SEMICONDUCTOR TECHNOLOGY INTERNATIONAL CONFERENCE 2012 (CSTIC 2012), 2012, 44 (01): : 1401 - 1405
  • [30] A SEGMENTED NEUTRON DETECTOR BASED ON SILICON-PIN PHOTODIODES USING NEUTRON-PROTON CONVERTERS
    Bayrak, Ahmet
    Yucel, Mete
    Barlas Yucel, Esra
    Ozben, Cenap S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (02): : 138 - 144