Study of silicon PIN diode responses to low energy gamma-rays

被引:7
|
作者
Lee, S. C. [1 ]
Jeon, H. B. [1 ]
Kang, K. H. [1 ]
Park, H. [1 ]
机构
[1] Kyungpook Natl Univ, Dept Phys, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
Low energy gamma-ray; Silicon PIN diode; Energy resolution; Signal-to-noise ratio; Detection speed; PERFORMANCE; DETECTORS;
D O I
10.3938/jkps.69.1587
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Low energy gamma-ray detectors play an important role in diagnosis in nuclear medicine, in detection of gamma-ray bursts for gravitational wave research and in detection of underground nuclear tests. The silicon positive-intrinsic-negative (PIN) diode detector is useful for detection of low energy gamma radiation without using a scintillator because it generates a high signal in a small active volume, has a fast response time and has good intrinsic energy resolution. We measured the detector responses, energy resolutions and signal-to-noise ratios for various gamma energies by using manufactured silicon PIN diode and photodiodes. Radioactive gamma sources, Am-241, Ba-133, and Co-57, providing gamma-rays with energies between 14.4 keV and 136.5 keV are used for the measurements. The energy resolution and the signal-to-noise ratio for 14.4 keV gamma-ray are measured to be 17.1 % and 12.8 for a 500 mu m thick silicon diode. The energy resolutions measured at the FWHM for 59.5 keV and 122.1 keV gamma-rays by using the silicon diode are better by up to two times compared to those obtained using the NaI:Tl or the BGO scintillator with a photomultiplier tube. The dependence of detection speeds of the signals on the diode's thickness is also measured.
引用
收藏
页码:1587 / 1590
页数:4
相关论文
共 50 条
  • [1] Study of silicon PIN diode responses to low energy gamma-rays
    S. C. Lee
    H. B. Jeon
    K. H. Kang
    H. Park
    Journal of the Korean Physical Society, 2016, 69 : 1587 - 1590
  • [2] Responses of Silicon PIN Diode to Low Energy Gamma Rays
    Lee, S. C.
    Jean, H. B.
    Park, H.
    Kang, K. H.
    Kim, T. H.
    2016 IEEE SENSORS, 2016,
  • [3] ON THE SCATTERING OF LOW ENERGY GAMMA-RAYS BY PROTONS
    FOLDY, LL
    PHYSICAL REVIEW, 1949, 75 (10): : 1634 - 1634
  • [4] A CIRCULAR POLARIMETER FOR LOW ENERGY GAMMA-RAYS
    BERNARDINI, M
    BROVETTO, P
    DEBENEDETTI, S
    FERRONI, S
    NUOVO CIMENTO, 1958, 7 (03): : 416 - 418
  • [5] COMPILATION OF LOW-ENERGY GAMMA-RAYS
    ARTNACOHEN, A
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1988, 40 (06): : 663 - 684
  • [7] EXTRAGALACTIC ORIGIN OF LOW-ENERGY GAMMA-RAYS
    DAMLE, SV
    DANIEL, RR
    JOSEPH, G
    LAVAKARE, PJ
    NATURE, 1972, 235 (5337) : 319 - &
  • [8] COSMIC FLUX OF LOW-ENERGY GAMMA-RAYS
    DAMLE, SV
    DANIEL, RR
    LAVAKARE, PJ
    JOSEPH, G
    ASTROPHYSICS AND SPACE SCIENCE, 1971, 14 (02) : 473 - &
  • [9] Absorption of high energy gamma-rays by low energy intergalactic photons
    Stecker, FW
    DeJager, OC
    SPACE SCIENCE REVIEWS, 1996, 75 (1-2) : 401 - 412
  • [10] RESONANCE SCATTERING OF LOW-ENERGY GAMMA-RAYS ON NUCLEI
    KALINKIN, BN
    SOVIET PHYSICS JETP-USSR, 1959, 9 (05): : 1022 - 1024