Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate:: Application to determination of copper in different water samples

被引:146
|
作者
Farajzadeh, Mir Ali [1 ]
Bahram, Morteza [2 ]
Mehr, Behzad Ghorbani [2 ]
Jonsson, Jan Ake [3 ]
机构
[1] Tabriz Univ, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[2] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
dispersive liquid-liquid microextraction; optimization; one variable at a time; central composite design; atomic absorption spectrometry; copper ion determination;
D O I
10.1016/j.talanta.2007.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study a dispersive liquid-liquid microextraction (DLLME) method based on the dispersion of an extraction solvent into aqueous phase in the presence of a dispersive solvent was investigated for the preconcentration of Cu2+ ions. 8-Hydroxy quinoline was used as a chelating agent prior to extraction. Flame atomic absorption spectrometry using an acetylene-air flame was used for quantitation of the analyte after preconcentration. The effect of various experimental parameters on the extraction was investigated using two optimization methods, one variable at a time and central composite design. The experimental design was performed at five levels of the operating parameters. Nearly the same results for optimization were obtained using both methods: sample size 5 mL; volume of dispersive solvent 1.5 mL; dispersive solvent methanol; extracting solvent chloroform; extracting solvent volume 250 mu L; 8-hydroxy quinoline concentration and salt amount do not affect significantly the extraction. Under the optimum conditions the calibration graph was linear over the range 50-2000 mu g L-1. The relative standard deviation was 5.1% for six repeated determinations at a concentration of 500 mu g L-1. The limit of detection (S/N = 3) was 3 mu g L-1. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:832 / 840
页数:9
相关论文
共 50 条
  • [22] Optimization and Application of dispersive liquid-liquid microextraction for decaBDE in water samples
    Jian, Yinghong
    Du, Xianyuan
    Liu, Jianlin
    Li, Yu
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 6066 - +
  • [23] Dispersive Liquid-Liquid Microextraction of Cr(VI) in Water and Hair Samples by Electrothermal Atomic Absorption Spectrometry
    Tehrani, Mohammad Saber
    Azar, Parviz Abroumand
    Husain, Syed Waqif
    Shafaei, Faezeh
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (08) : 6302 - 6310
  • [24] Speciation of chromium in water samples using dispersive liquid-liquid microextraction and flame atomic absorption spectrometry
    Hemmatkhah, Payam
    Bidari, Araz
    Jafarvand, Sanaz
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 69 - 75
  • [25] Determination of copper in rose tea samples using flame atomic absorption spectrometry after emulsification liquid-liquid microextraction
    Kartoglu, Bedrihan
    Bodur, Suleyman
    Zeydanli, Damla
    Gover, Tugce
    Ozaydin, Ecem
    Bakirdere, Emine Gulhan
    Bakirdere, Sezgin
    FOOD CHEMISTRY, 2024, 439
  • [26] On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples
    Anthemidis, Aristidis N.
    Ioannou, Kallirroy-Ioanna G.
    TALANTA, 2009, 79 (01) : 86 - 91
  • [27] Ultrasound-assisted ionic liquid based dispersive liquid-liquid microextraction and flame atomic absorption spectrometry of cobalt, copper, and zinc in environmental water samples
    Rajabi, Maryam
    Asemipour, Somayeh
    Barfi, Behruz
    Jamali, Mohammad Reza
    Behzad, Mandi
    JOURNAL OF MOLECULAR LIQUIDS, 2014, 194 : 166 - 171
  • [28] Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid-Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Liu, Yaqi
    Han, Quan
    Huo, Yanyan
    Yang, Xiaohui
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2024, 46 (05) : 480 - 490
  • [29] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples
    Abadi, M. Dehghani Mohammad
    Chamsaz, M.
    Arbab-Zavar, M. H.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (07) : 3984 - 3988
  • [30] Development of Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Sensitive Determination of Trace Copper in Water and Beverage Samples by Flame Atomic Absorption Spectrometry
    Wu, Chunxia
    Zhao, Bin
    Li, Yingli
    Wu, Qiuhua
    Wang, Chun
    Wang, Zhi
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (03): : 829 - 835