Microwave System and Methods for Combined Heating and Radiometric Sensing for Blood Perfusion Measurement of Tissue

被引:0
|
作者
Tofighi, Mohammad-Reza [1 ]
Pardeshi, Jayendrasingh R. [1 ]
Maicke, Brian A. [1 ]
机构
[1] Penn State Univ, Harrisburg, PA 17057 USA
关键词
Microwave heating; microwave radiometry; blood perfusion measurement; bioheat transfer; FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A combination of microwave heating and radiometry provides a promising means of the noninvasive measurement of blood perfusion. In this paper, a microwave system, along with a perfusion mimicking setup, for perfusion/flow measurement is described. This paper also presents for the first time i) considerations for achieving high sensitivity of temperature response versus flow, ii) radiometric measurement of temperature decay at the presence of flow, iii) a proper choice of the perfusion phantom to mimic the tissue permittivity, and iv) insights on the proper choice of heating and radiometry frequencies from the near-field antenna beam and bioheat transfer considerations.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] COMPUTER-BASED SYSTEM FOR CONTINUOUS ONLINE MEASUREMENTS OF TISSUE BLOOD PERFUSION
    ARKIN, H
    HOLMES, KR
    CHEN, MM
    JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (01): : 38 - 45
  • [42] Reduction of red blood spots in cooked marinated chicken breast meat by combined microwave heating and steaming
    Jantaranikorn, Matthanee
    Thumanu, Kanjana
    Yongsawatdigul, Jirawat
    POULTRY SCIENCE, 2023, 102 (01)
  • [43] A SENSITIVITY ANALYSIS OF THE THERMAL PULSE DECAY METHOD FOR MEASUREMENT OF LOCAL TISSUE CONDUCTIVITY AND BLOOD PERFUSION
    ARKIN, H
    HOLMES, KR
    CHEN, MM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (01): : 54 - 58
  • [44] A sensitivity analysis of the thermal pulse decay method for measurement of local tissue conductivity and blood perfusion
    Arkin, H.
    Holmes, K.R.
    Chen, M.M.
    Journal of Biomechanical Engineering, 1986, 108 (01) : 54 - 58
  • [45] Tissue-engineering bioreactors: A new combined cell-seeding and perfusion system for vascular tissue engineering
    Sodian, R
    Lemke, T
    Fritsche, C
    Hoerstrup, SP
    Fu, P
    Potapov, EV
    Hausmann, H
    Hetzer, R
    TISSUE ENGINEERING, 2002, 8 (05): : 863 - 870
  • [46] Asymptotic analysis of transient heating on the triple-layered skin tissue with temperature dependent blood perfusion rate
    Wang, Ying Ze
    Li, Mei Jun
    Liu, Dong
    WAVES IN RANDOM AND COMPLEX MEDIA, 2021,
  • [47] Position detection system of shearer based on combined measurement of multiple sensing modes
    Zhang Z.
    Fu S.
    Liu C.
    Li Y.
    Lan Y.
    Wu M.
    Meitan Kexue Jishu/Coal Science and Technology (Peking), 2021, 49 (11): : 218 - 224
  • [48] Optical methods for blood perfusion measurement-theoretical comparison among four different modalities
    Bi, Renzhe
    Dong, Jing
    Poh, Chueh Loo
    Lee, Kijoon
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (05) : 860 - 866
  • [49] Computer modeling of the combined effects of perfusion, electrical conductivity, and thermal conductivity on tissue heating patterns in radiofrequency tumor ablation
    Ahmed, Muneeb
    Liu, Zhengjun
    Humphries, Stanley
    Goldberg, S. Nahum
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2008, 24 (07) : 577 - 588
  • [50] In vivo preclinical verification of a multimodal diffuse reflectance and correlation spectroscopy system for sensing tissue perfusion
    Pakela, Julia M.
    Lee, Seung Yup
    Hedrick, Taylor L.
    Vishwanath, Karthik
    Helton, Michael C.
    Chung, Yooree G.
    Kolodziejski, Noah J.
    Stapels, Christopher J.
    McAdams, Daniel R.
    Fernandez, Daniel E.
    Christian, James F.
    O'Reilly, Jameson
    Farkas, Dana
    Ward, Brent B.
    Feinberg, Stephen E.
    Mycek, Mary-Ann
    OPTICAL DIAGNOSTICS AND SENSING XVII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2017, 10072