Microwave System and Methods for Combined Heating and Radiometric Sensing for Blood Perfusion Measurement of Tissue

被引:0
|
作者
Tofighi, Mohammad-Reza [1 ]
Pardeshi, Jayendrasingh R. [1 ]
Maicke, Brian A. [1 ]
机构
[1] Penn State Univ, Harrisburg, PA 17057 USA
关键词
Microwave heating; microwave radiometry; blood perfusion measurement; bioheat transfer; FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A combination of microwave heating and radiometry provides a promising means of the noninvasive measurement of blood perfusion. In this paper, a microwave system, along with a perfusion mimicking setup, for perfusion/flow measurement is described. This paper also presents for the first time i) considerations for achieving high sensitivity of temperature response versus flow, ii) radiometric measurement of temperature decay at the presence of flow, iii) a proper choice of the perfusion phantom to mimic the tissue permittivity, and iv) insights on the proper choice of heating and radiometry frequencies from the near-field antenna beam and bioheat transfer considerations.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Recent nonlinear inversion methods and measurement system for microwave imaging
    Pichot, C
    Dauvignac, JY
    Aliferis, L
    Le Brusq, E
    Ferrayé, R
    Chatelée, V
    2004 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2004, : 95 - 99
  • [32] A COMBINED HEAT CLEARANCE METHOD FOR TISSUE BLOOD-FLOW MEASUREMENT
    ABRAMOVICHSIVAN, S
    BENARY, V
    KASPI, T
    AKSELROD, S
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (04): : 438 - 445
  • [33] Heating surimi products using microwave combined with steam methods: Study on energy saving and quality
    Cao, Hongwei
    Fan, Daming
    Jiao, Xidong
    Huang, Jianlian
    Zhao, Jianxin
    Yan, Bowen
    Zhou, Wenguo
    Zhang, Wenhai
    Zhang, Hao
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2018, 47 : 231 - 240
  • [34] Methods of blood flow measurement in the arterial circulatory system
    Tabrizchi, R
    Pugsley, MK
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2000, 44 (02) : 375 - 384
  • [35] DEUTERIUM MAGNETIC-RESONANCE INVIVO - THE MEASUREMENT OF BLOOD-FLOW AND TISSUE PERFUSION
    ACKERMAN, JJH
    EWY, CS
    KIM, SG
    SHALWITZ, RA
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1987, 508 : 89 - 98
  • [36] Closed-Loop Pulse-Width Modulation Microwave Heating With Infrared Temperature Control for Perfusion Measurement
    Tofighi, Mohammad-Reza
    Attaluri, Anilchandra
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [37] MEASUREMENT OF ADIPOSE TISSUE BLOOD FLOW AND PERFUSION IN MAN BY UPTAKE OF 85KR
    LESSER, GT
    DEUTSCH, S
    JOURNAL OF APPLIED PHYSIOLOGY, 1967, 23 (05) : 621 - +
  • [38] TELEMEDICINE SYSTEM FOR COMBINED MEASUREMENT OF BLOOD PRESSURE AND PHYSICAL ACTIVITY
    Muzik, J.
    Peleska, J.
    Camek, R.
    Doksansky, M.
    Kucera, T.
    Holubova, A.
    Fiala, D.
    Kaspar, J.
    Caithaml, V.
    Navratil, V.
    Gillar, D.
    Jedlickova, P.
    Hana, K.
    Drs, P.
    Muzny, M.
    JOURNAL OF HYPERTENSION, 2019, 37 : E232 - E233
  • [39] New Microwave Sensing System for Blade Tip Clearance Measurement in Gas Turbines
    Violetti, Maddalena
    Skrivervik, Anja K.
    Xu, Qin
    Hafner, Michael
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 307 - 310
  • [40] Design of a Microwave Heating and Permittivity Measurement System Based on Oblique Aperture Ridge Waveguide
    Gou, Mingyi
    Chen, Qian
    Dong, Penghao
    Liu, Changjun
    Huang, Kama
    SENSORS, 2023, 23 (08)