Cardiac gated breath-hold black blood MRI of the coronary artery wall: An in vivo and ex vivo comparison

被引:8
|
作者
Worthley, SG [1 ]
Helft, G [1 ]
Fayad, ZA [1 ]
Fuster, V [1 ]
Rodriguez, OJ [1 ]
Zaman, AG [1 ]
Badimon, JJ [1 ]
机构
[1] Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, Cardiovasc Biol Res Lab, New York, NY 10029 USA
来源
关键词
coronary; motion suppression; MRI;
D O I
10.1023/A:1010688122184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: High resolution magnetic resonance (MR) imaging of the coronary artery wall in vivo has been limited by the cardiac and respiratory motion, flow artifacts as well as the relatively small size of the coronary arteries. We sought to validate in vivo black blood MR imaging of the coronary artery wall using a double inversion recovery fast spin echo MR imaging sequence with limited breath-holding and cardiac gating for suppression of motion artifacts by comparison with ex vivo MR imaging. Methods: Yorkshire albino swine (n = 6) were used in this study and coronary lesions were induced with balloon angioplasty. Four weeks after balloon injury of the coronary arteries MR imaging of the coronary artery lesions was performed. High resolution in vivo and ex vivo images of the coronary artery wall and lesions were obtained using a double inversion recovery fast spin echo sequence in a 1.5 T MR system. There was a statistically significant agreement (p < 0.0001) between measurements of vessel wall area (r = 0.87, slope = 0.87) and maximal wall thickness (r = 0.84, slope = 0.88) from in vivo and ex vivo MR images of the coronary arteries. The mean differences between in vivo and ex vivo measurements were 0.56 +/- 1.98 mm(2) for vessel wall area and 0.02 +/- 0.36 mm for maximal wall thickness. Conclusions: Using breath-holding and cardiac gating, it is possible to perform high resolution MR imaging of the coronary artery wall in vivo with good suppression of motion artifacts with a double inversion recovery fast spin echo black blood imaging sequence.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [1] Cardiac gated breath-hold black blood MRI of the coronary artery wall: An in vivo and ex vivo comparison
    Stephen G. Worthley
    Gérard Helft
    Zahi A. Fayad
    Valentin Fuster
    Oswaldo J. Rodriguez
    Azfar G. Zaman
    Juan J. Badimon
    The International Journal of Cardiovascular Imaging, 2001, 17 : 195 - 201
  • [2] Magnetic resonance coronary angiography: Comparison between respiratory gated and breath-hold imaging
    Regenfus, M
    Ropers, D
    Achenbach, S
    Kessler, W
    Laub, G
    Daniel, WG
    Moshage, W
    CIRCULATION, 2000, 102 (18) : 459 - 459
  • [3] Magnetic resonance coronary angiography: comparison between respiratory gated and breath-hold imaging
    Regenfus, M
    Ropers, D
    Achenbach, S
    Kessler, W
    Daniel, WG
    Laub, G
    Moshage, W
    EUROPEAN HEART JOURNAL, 2000, 21 : 565 - 565
  • [4] Inter breath-hold reproducibility of temporal patterns of coronary artery blood flow
    Stephen Strain
    Jennifer Keegan
    Claire E Raphael
    Robin Simpson
    Malindie H Sugathapala
    Sanjay K Prasad
    David Firmin
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [5] INTER-STUDY REPRODUCIBILITY OF STRAIN MEASURMENTS BY CARDIAC MRI: A COMPARISON OF FEATURE TRACKING, SINGLE BREATH-HOLD TAGGING AND MULTI BREATH-HOLD TAGGING
    Singh, A.
    Steadman, C. D.
    Khan, J. N.
    Nazir, S. A.
    McCann, G. P.
    HEART, 2013, 99
  • [6] Artifact-free black-blood cine cardiac imaging in a single breath-hold
    Fahmy, Ahmed S.
    Pan, Li
    Osman, Nael F.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (10) : 1303 - 1310
  • [7] In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches
    Nielles-Vallespin, Sonia
    Mekkaoui, Choukri
    Gatehouse, Peter
    Reese, Timothy G.
    Keegan, Jennifer
    Ferreira, Pedro F.
    Collins, Steve
    Speier, Peter
    Feiweier, Thorsten
    de Silva, Ranil
    Jackowski, Marcel P.
    Pennell, Dudley J.
    Sosnovik, David E.
    Firmin, David
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 454 - 465
  • [8] Detection of coronary artery stenosis using three-dimensional magnetic resonance coronary angiography: Comparison of contrast-enhanced breath-hold and respiratory gated imaging
    Regenfus, M
    Ropers, D
    Achenbach, S
    Kessler, W
    Laub, G
    Moshage, W
    CIRCULATION, 2001, 104 (17) : 721 - 721
  • [10] MRI OF CORONARY-ARTERIES - 2D BREATH-HOLD VS 3D RESPIRATORY-GATED ACQUISITION
    HOFMAN, MBM
    PASCHAL, CB
    LI, DB
    HAACKE, EM
    VANROSSUM, AC
    SPRENGER, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (01) : 56 - 62